Clinical, Biomechanical and Morphological Assessment of Anterior Cruciate Ligament Kevlar®-Based Artificial Prosthesis in Rabbit Model
Source abstract
Abstract
Background The aim of this study was to evaluate the clinical, biomechanical and morphological characteristics of a Kevlar®-based prosthetic ligament as a synthetic graft of the anterior cruciate ligament (ACL) in an experimental animal model in rabbits. Methods A total of 27 knees of rabbits randomly divided into 3 groups (control, ACL excision and ACL replacement with a Kevlar® prosthesis) were analyzed using clinical, biomechanical and morphological tests at 6, 12 and 18 weeks postprocedure. Results The mean displacement in mechanical testing was 0.73 ± 0.06 mm, 1.58 ± 0.19 mm and 0.94 ± 0.20 mm for the control, ACL excision and ACL replacement with synthetic prosthesis groups, respectively. The results showed an improvement in the stability of the knee with the use of the Kevlar® synthetic prosthesis in the biomechanical testing (p<0.05) compared with rabbits that underwent ACL excision, in addition to displacements that were larger but comparable to that in the control group (p>0.05), between the replacement group and the control group. The histological study revealed a good morphological adaptation of the synthetic material to the knee. Conclusions This study proposes a new animal model for the placement and evaluation of Kevlar®-based synthetic ACL implants. The studied prosthesis showed promising behavior in the clinical and biomechanical tests and in the histological analysis. This study lays the foundation for further basic and clinical studies of artificial ACL prostheses using this material.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes · Osteoarthritis Treatment and Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Knee Unit, Department of Orthopaedics and Traumatology, Faculty of Medicine and Dr. José Eleuterio González University Hospital, Autonomous University of Nuevo León, Monterrey, Nuevo León - México
Department of Human Anatomy, Faculty of Medicine, Autonomous University of Nuevo León, Monterrey, Nuevo León - México
Department of Histology, Faculty of Medicine, Autonomous University of Nuevo León, Monterrey, Nuevo León - México
References (43)
Show source-provided references
1. 10.1302/0301-620X.70B4.340361310.1302/0301-620X.70B4.3403613 ↗
2. 10.1302/0301-620X.74B4.162452410.1302/0301-620X.74B4.1624524 ↗
3. 10.2302/kjm.50.16110.2302/kjm.50.161 ↗
4. 10.1302/0301-620X.73B2.200515110.1302/0301-620X.73B2.2005151 ↗
5. 10.1302/0301-620X.75B5.837644810.1302/0301-620X.75B5.8376448 ↗
6. 10.1302/0301-620X.76B2.811327010.1302/0301-620X.76B2.8113270 ↗
7. Mascarenhas R · Mcgill J Med · 2008 · 11 · 29
8. 10.1177/036354650731238110.1177/0363546507312381 ↗
9. 10.1098/rsif.2009.0079.focus10.1098/rsif.2009.0079.focus ↗
10. Lim JY · J Musculoskelet Neuronal Interact · 2004 · 4 · 396
11. 10.1007/BF0005898010.1007/BF00058980 ↗
12. 10.4067/S0717-9502201500020004210.4067/S0717-95022015000200042 ↗
13. 10.1002/jbm.82021011010.1002/jbm.820210110 ↗
14. Müller U · Med Device Technol · 2008 · 19 · 30
15. Passuti N · Rev Chir Orthop Reparatrice Appar Mot · 1989 · 75 · 353
16. 10.1177/019262330731094910.1177/0192623307310949 ↗
17. 10.1089/10979330175340793910.1089/109793301753407939 ↗
18. 10.1177/08853282870020010410.1177/088532828700200104 ↗
19. Bollen LS · Med Device Technol · 2000 · 11 · 8
20. Williams D · Med Device Technol · 2009 · 20 · 8
21. 10.1016/j.jss.2012.01.05210.1016/j.jss.2012.01.052 ↗
22. 10.1007/s00402-007-0320-010.1007/s00402-007-0320-0 ↗
23. DuPont. Kevlar® properties: technical guide. http://www.dupont.com/products-and-services/fabrics-fibers-nonwovens/fibers/articles/kevlar-properties.html. Accessed December 14, 2014.
24. Compeán-Martínez GA · Eur J Anat · 2013 · 176
25. 10.1056/NEJMcp080474510.1056/NEJMcp0804745 ↗
26. 10.1016/j.arthro.2014.11.03210.1016/j.arthro.2014.11.032 ↗
27. 10.1007/s00264-010-0963-210.1007/s00264-010-0963-2 ↗
28. 10.1016/j.knee.2015.06.00310.1016/j.knee.2015.06.003 ↗
29. 10.1111/j.1365-2230.2004.01691.x10.1111/j.1365-2230.2004.01691.x ↗
30. 10.1100/2012/34285410.1100/2012/342854 ↗
31. 10.1139/y03-10110.1139/y03-101 ↗
32. 10.1046/j.1523-1747.1998.00329.x10.1046/j.1523-1747.1998.00329.x ↗
33. 10.1002/(SICI)1097-4644(19960616)61:4<569::AID-JCB10>3.0.CO;2-B10.1002/(SICI)1097-4644(19960616)61:4<569::AID-JCB10>3.0.CO;2-B ↗
34. Furuzawa CG · Rev Odont Mex · 2005 · 191
35. 10.1006/excr.1998.409410.1006/excr.1998.4094 ↗
36. 10.1007/BF0004760010.1007/BF00047600 ↗
37. 10.1074/jbc.273.18.1134210.1074/jbc.273.18.11342 ↗
38. 10.1016/j.biomaterials.2006.11.05010.1016/j.biomaterials.2006.11.050 ↗
39. 10.1002/jbm.82021011010.1002/jbm.820210110 ↗
40. 10.1007/s10354-011-0913-710.1007/s10354-011-0913-7 ↗
41. 10.1177/03635465930210011510.1177/036354659302100115 ↗
42. 10.1016/0268-0033(95)91398-X10.1016/0268-0033(95)91398-X ↗
43. WeningJV KatzerA NicolasV HahnM JungbluthKH KratzerA [Imaging of alloplastic ligament implant: an in vivo and in vitro study exemplified by Kevlar] [article in German]. Unfallchirurgie. 1994;20(2):61-65.10.1007/BF02588144 ↗