journal article·2015-07Open access

Local Blood Flow Patterns in Stented Coronary Bifurcations: An Experimental and Numerical Study

Jaime S. Raben, Stefano Morlacchi, Francesco Burzotta, Francesco Migliavacca, Pavlos P. Vlachos

Abstract

Purpose Despite the atheroprone environment of blood flow in coronary bifurcations, limited quantitative information is available on the hemodynamics occurring in these geometries, both before and after their treatment with endovascular stents. Previous studies have focused on computational fluid dynamics (CFD) analyses and have bypassed the challenges associated with experimentally representing the flow environment, providing no means for validation. This study analyzed steady flow conditions in 3 bifurcation angles and 4 different single- and double-stenting procedures, which are used clinically in coronary bifurcations. Methods The numerical aspect of this study utilized geometries derived from CAD models (nonstented cases) and finite element simulations (stented cases). Digital particle image velocimetry (DPIV) testing was conducted within compliant bifurcating models for which an uncertainty analysis was performed at each measurement location for CFD validation purposes. Results were analyzed in terms of velocity magnitude contour maps and axial velocity profiles at several locations in the bifurcated vessels. Results and Conclusions Qualitatively, the 2 approaches showed agreement in the bulk flow patterns. However, the velocity computed with CFD was outside the DPIV uncertainty estimates, which can be attributed to the intrinsic difference and modeling assumptions of the 2 approaches. The findings reveal that wider bifurcation angles and double-stenting procedures are both characterized by increased areas of low flow and recirculation. Additionally, inferior performance in terms of viscous and wall shear stresses was observed in double-stented cases.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Coronary Interventions and Diagnostics · Cardiovascular Health and Disease Prevention · Advanced Numerical Methods in Computational Mathematics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia - USA

Laboratory of Biological Structure Mechanics (LaBS), Chemistry, Materials and Chemical Engineering Department Giulio Natta, Politecnico di Milano, Milan - Italy

Department of Cardiovascular Sciences, Catholic University of the Sacred Heart, Rome - Italy

School of Mechanical Engineering, Purdue University, West Lafayette, Indiana - USA

References (40)

Show source-provided references
1. 10.1016/S0002-9149(98)00189-110.1016/S0002-9149(98)00189-1 ↗
2. 10.1016/j.jacc.2011.10.90310.1016/j.jacc.2011.10.903 ↗
3. 10.4244/EIJV6SUPJA910.4244/EIJV6SUPJA9 ↗
4. 10.1080/1025584100376684510.1080/10255841003766845 ↗
5. 10.1007/s10439-012-0681-610.1007/s10439-012-0681-6 ↗
6. 10.1016/j.compbiomed.2010.02.00510.1016/j.compbiomed.2010.02.005 ↗
7. 10.1243/09544119JEIM64910.1243/09544119JEIM649 ↗
8. 10.1016/j.jcin.2008.06.00310.1016/j.jcin.2008.06.003 ↗
9. 10.1007/s10439-009-9697-y10.1007/s10439-009-9697-y ↗
10. 10.1007/s10439-010-9915-710.1007/s10439-010-9915-7 ↗
11. 10.1115/1.179790410.1115/1.1797904 ↗
12. 10.1016/j.jbiomech.2011.12.01610.1016/j.jbiomech.2011.12.016 ↗
13. 10.1227/01.NEU.0000223495.39240.9A10.1227/01.NEU.0000223495.39240.9A ↗
14. 10.1115/1.290072410.1115/1.2900724 ↗
15. 10.1002/cnm.145910.1002/cnm.1459 ↗
16. 10.1115/1.400547610.1115/1.4005476 ↗
17. 10.1002/ccd.2131410.1002/ccd.21314 ↗
18. 10.1115/1.48325610.1115/1.483256 ↗
19. 10.1088/0957-0233/20/5/05540110.1088/0957-0233/20/5/055401 ↗
20. 10.1088/0957-0233/20/7/07540210.1088/0957-0233/20/7/075402 ↗
21. 10.1007/s00348-008-0492-610.1007/s00348-008-0492-6 ↗
22. 10.1007/s00348005008210.1007/s003480050082 ↗
23. 10.1088/0957-0233/13/1/20110.1088/0957-0233/13/1/201 ↗
24. 10.1016/S0009-2509(99)00233-X10.1016/S0009-2509(99)00233-X ↗
25. 10.1007/s00348-005-0016-610.1007/s00348-005-0016-6 ↗
26. 10.1088/0957-0233/24/6/06530110.1088/0957-0233/24/6/065301 ↗
27. TimminsBH SmithBL VlachosPP Automatic particle image velocimetry uncertainty quantification. Proceedings of the Asme Fluids Engineering Division Summer Conference. 2010 1Pts A-C 2811–2826.10.1115/FEDSM-ICNMM2010-30724 ↗
28. 10.1007/BF0038462310.1007/BF00384623 ↗
29. 10.1364/AO.29.00299710.1364/AO.29.002997 ↗
30. PoncinP MilletC ChevyJ ProftJL Comparing and optimizing Co-cr tubing for stent applications. In: Medical Device Materials II - Materials Processes for Medical Devices Conference 2004 St. Paul, MN United States 25-27 August 2004 ASM International. 2005 279–283.
31. 10.1007/s10237-010-0196-810.1007/s10237-010-0196-8 ↗
32. 10.1016/j.medengphy.2013.01.00710.1016/j.medengphy.2013.01.007 ↗
33. 10.1016/j.euromechflu.2012.01.01110.1016/j.euromechflu.2012.01.011 ↗
34. 10.1161/01.RES.66.4.104510.1161/01.RES.66.4.1045 ↗
35. 10.4244/EIJV6SUPJA410.4244/EIJV6SUPJA4 ↗
36. 10.1161/ATVB.17v07.135610.1161/ATVB.17v07.1356 ↗
37. 10.1016/0021-9150(83)90071-010.1016/0021-9150(83)90071-0 ↗
38. 10.1161/CIRCINTERVENTIONS.110.95851210.1161/CIRCINTERVENTIONS.110.958512 ↗
39. 10.4244/EIJV6SUPJA510.4244/EIJV6SUPJA5 ↗
40. 10.1253/circj.CJ-12-027210.1253/circj.CJ-12-0272 ↗