journal article·2015-07Open access

Mechanical and Biocompatibility Performance of Bicomponent Polyester/Silk Fibroin Small-Diameter Arterial Prostheses

Xiaoyuan Yang, Lu Wang, Guoping Guan, Hongqi Zhang, Gaotian Shen, Ying Guan, Lei Peng, Yuling Li, Martin W. King

Abstract

Background In this study, we fabricated prototype bicomponent polyester/silk fibroin small-diameter arterial prostheses using a specially designed narrow ribbon shuttle loom. Methods The 2-layered flat fabrics were then heatset on a mandrel to form tubes with a round cross section. Results The woven samples had a wall thickness between 0.23 mm and 0.29 mm and an inner diameter between 3.53 mm and 3.95 mm, depending on the yarn type and the weave structure. Conclusions The bicomponent polyester/silk fibroin samples had superior bursting strength, circumferential strength and suture retention strength compared with a commercial small-diameter arterial prosthesis made from ePTFE. In addition, these prototype samples had greater suture retention strengths than a dog femoral artery, which indicates that they have adequate biostability for clinical use. While their amount of radial compliance was superior to that of the ePTFE commercial graft control, it did not match that of a natural artery. So there is still a need for future improvement in compliance. All of the woven prototypes had water permeability values between 26 and 180 ml/(cm2*min), which confirms that none of these arterial prostheses needs to be preclotted at the time of implantation. The biocompatibility of the woven prototypes was evaluated using porcine endothelial cells and an MTT assay. Their cytocompatibility was found to be superior to the ePTFE commercial control, and the level of cell attachment was observed to increase on these prototypes woven with a higher silk fibroin content.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Silk-based biomaterials and applications · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Lab of Textile Science and Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai - PR China

College of Textiles, North Carolina State University, Raleigh, North Carolina - USA

Shanghai Medical College, Fudan University, Shanghai - PR China

References (21)

Show source-provided references
1. 10.1002/jbm.a.3329810.1002/jbm.a.33298 ↗
2. 10.1016/j.pnsc.2012.03.00510.1016/j.pnsc.2012.03.005 ↗
3. 10.1016/j.biomaterials.2008.11.01110.1016/j.biomaterials.2008.11.011 ↗
4. 10.1080/0040500070167958210.1080/00405000701679582 ↗
5. 10.1177/088532820809943710.1177/0885328208099437 ↗
6. 10.1016/j.msec.2013.04.02710.1016/j.msec.2013.04.027 ↗
7. 10.1016/j.apsusc.2008.06.00910.1016/j.apsusc.2008.06.009 ↗
8. 10.1016/j.biomaterials.2003.08.04510.1016/j.biomaterials.2003.08.045 ↗
9. 10.1016/j.jvs.2009.09.00510.1016/j.jvs.2009.09.005 ↗
10. 10.1159/00046033810.1159/000460338 ↗
11. 10.1016/S0142-9612(99)00231-810.1016/S0142-9612(99)00231-8 ↗
12. 10.1053/j.semvascsurg.2011.10.01510.1053/j.semvascsurg.2011.10.015 ↗
13. 10.1002/jbm.b.3195510.1002/jbm.b.31955 ↗
14. 10.1002/jbm.a.3413610.1002/jbm.a.34136 ↗
15. Peng L · 2012 · pp.185
16. Geneva, Switzerland: International Organization for Standardization; · 1998 · 11
17. 10.1177/088532821247221610.1177/0885328212472216 ↗
18. JiXP The analysis of wall structure and properties of small diameter ePTFE vascular prosthesis [master's thesis]. Shanghai Donghua University 2011
19. 10.1007/978-3-642-29305-4_4810.1007/978-3-642-29305-4_48 ↗
20. 10.1016/j.colsurfb.2010.09.00210.1016/j.colsurfb.2010.09.002 ↗
21. 10.1111/j.1365-2591.2011.01863.x10.1111/j.1365-2591.2011.01863.x ↗