journal article·2017-01

A Biaxial Strain–Based Expansion Mechanism for Auxetic Stent Deployment

Faiza Bukhari, Umar Ansari, Murtaza Najabat Ali, Hafsah Akhtar, Sarim Asif, Umer Mohammad, Mariam Mir

Publisher page

Abstract

Background Auxetics, a special class of materials, tend to expand both in the radial and longitudinal directions when a unidirectional tensile force is applied. Recently, studies have come up with new designs for auxetic vascular and nonvascular stents which are deployed with commercial balloon catheters. There are some inherent limitations associated with a unidirectional application of expansion force in the effective deployment of stents. This work proposed a solution to some of these limitations through the use of a biaxial mode of a predetermined strain-based expansion mechanism. Method The design incorporated a pressure-activated crank-slider mechanism. Fabrication of a prototype for experimental verification was carried out through milling and high-speed lathe machining. The testing of the device employed the use of auxetic stents, fabricated from a biocompatible polymer. A finite element study is presented to extrapolate experimental results to a broader range of operation and working conditions. Results and Conclusions The expansion mechanism is similar in operation to the opening of an umbrella. The length of the connected auxetic stent increases when internal hydraulic pressure is applied. The degree of linear expansion in 1 direction influences the expansion of auxetic stent in the lateral direction. As the device exerts pressure longitudinally, a larger amount of the force is distributed on the unit cells/hinges which ultimately results in an increased expansion of the stent.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cellular and Composite Structures · Soft Robotics and Applications · Shape Memory Alloy Transformations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Biomedical Engineering and Sciences Department, School of Mechanical and Manufacturing Engineering, National University of Sciences and Technology (NUST), Islamabad - Pakistan

References (16)

Show source-provided references
1. 10.1002/pssb.20046038810.1002/pssb.200460388 ↗
2. 10.1023/A:101860692609410.1023/A:1018606926094 ↗
3. 10.1016/S0021-9290(00)00098-110.1016/S0021-9290(00)00098-1 ↗
4. 10.1016/j.biomaterials.2005.10.01210.1016/j.biomaterials.2005.10.012 ↗
5. 10.1016/j.biomaterials.2006.11.04210.1016/j.biomaterials.2006.11.042 ↗
6. Green M · US Patent Application 13/475,769. Date of presentation: May 18th 2012. Application number: US 20130305512 A1
7. Mariam Mir · Adv Mater Sci Eng · 2014
8. Liu Y · Sci Res Essays · 2010 · 1052
9. 10.1002/pssb.20138425710.1002/pssb.201384257 ↗
10. 10.1080/03602559.2015.102148110.1080/03602559.2015.1021481 ↗
11. 10.1007/s10856-013-5067-210.1007/s10856-013-5067-2 ↗
12. 10.1056/NEJMoa06663310.1056/NEJMoa066633 ↗
13. 10.1056/NEJMoa06772210.1056/NEJMoa067722 ↗
14. 10.1002/pssb.20046037610.1002/pssb.200460376 ↗
15. 10.1080/03602559.2015.102148110.1080/03602559.2015.1021481 ↗
16. 10.1007/s12541-012-0099-y10.1007/s12541-012-0099-y ↗