journal article·2014-09

Compliance Properties of Collagen-coated Polyethylene Terephthalate Vascular Prostheses

Foued Khoffi, Daniel Mathieu, Florence Dieval, Nabil Chakfé, Bernard Durand

Publisher page

Abstract

Background Compliance mismatch between native artery and a prosthetic graft used for infrainguinal bypass is said to be a factor for graft failure. The aim of this study was to develop a technique for measuring the compliance of collagen-coated polyethylene terephthalate (PET) vascular prostheses and to analyze the influence of several key properties on the elastic behavior of the grafts. Methods Compliance testing was performed on 3 prostheses with and without internal compliant membrane (ICM). The principle of this test was to study the dimensional changes of prostheses submitted to internal pressure from 30 to 240 mm Hg at intervals of predetermined values. Results We demonstrated that the ICM created links with the inner surface of the crimps and considerably modified the graft behavior when submitted to internal pressure. The results showed that compliance properties were dependent on the wall thickness and the crimping geometry of textile vascular prostheses. Mechanical analysis predicts the circumferential tensile behavior of these arterial grafts and validates tests for measuring compliance.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Infectious Aortic and Vascular Conditions · Peripheral Artery Disease Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory of Textile Physics and Mechanics, University of Haute Alsace, Mulhouse - France

European Research Group on Grafts Used in Vascular Surgery (ERGGVS), Faculty of Medicine, Strasbourg - France

Departement of Vascular Surgery, University Hospitals of Strasbourg, Strasbourg - France

References (43)

Show source-provided references
1. WesolowskiS.A., FriesC.C., HennigarG., FoxL.M., SawyerP.N., SauvageL.R. Factors contributing to long-term failures in human vascular prosthetic grafts. J Cardiovasc Surg (Torino). 1964; 5: 544–567.
2. 10.1177/08853282870020020110.1177/088532828700200201 ↗
3. DownsA.R., GuzmanR., FormichiM. Etiology of prosthetic anastomotic false aneurysms: pathologic and structural evaluation in 26 cases. Can J Surg. 1991; 34(1): 53–58.
4. 10.1053/ejvs.1998.067410.1053/ejvs.1998.0674 ↗
5. 10.1016/S1078-5884(05)80163-710.1016/S1078-5884(05)80163-7 ↗
6. 10.1146/annurev.bioeng.8.010506.10502310.1146/annurev.bioeng.8.010506.105023 ↗
7. 10.1016/0741-5214(87)90148-010.1016/0741-5214(87)90148-0 ↗
8. 10.1016/0741-5214(85)90095-310.1016/0741-5214(85)90095-3 ↗
9. 10.1016/0741-5214(89)90217-610.1016/0741-5214(89)90217-6 ↗
10. 10.1106/NA5T-J57A-JTDD-FD0410.1106/NA5T-J57A-JTDD-FD04 ↗
11. 10.1023/B:ABME.0000032462.56207.6510.1023/B:ABME.0000032462.56207.65 ↗
12. 10.3233/BME-1992-240110.3233/BME-1992-2401 ↗
13. 10.1007/BF0244617910.1007/BF02446179 ↗
14. 10.3233/BIR-1993-3020310.3233/BIR-1993-30203 ↗
15. 10.1016/S1350-4533(02)00216-310.1016/S1350-4533(02)00216-3 ↗
16. KinleyC.E., PaascheP.E., MacDonaldA.S., MarbleA.E. Stress at vascular anastomosis in relation to host artery: synthetic graft diameter. Surgery. 1974; 75(1): 28–30.
17. ClowesA.W., GownA.M., HansonS.R., ReidyM.A. Mechanisms of arterial graft failure. 1. Role of cellular proliferation in early healing of PTFE prostheses. Am J Pathol. 1985; 118(1): 43–54.
18. MegermanJ., AbbottW.A. Compliance in vascular grafts. In: WrightC.B., ed. Vascular grafting: clinical applications and techniques. John Wright, PSG; Boston 1983: 344–364.
19. 10.1006/jsre.2000.604210.1006/jsre.2000.6042 ↗
20. 10.1016/S0010-4825(02)00059-810.1016/S0010-4825(02)00059-8 ↗
21. 10.1097/00002480-199004000-0000910.1097/00002480-199004000-00009 ↗
22. ShuM., HwangN. Flow phenomenon in compliant and non-compliant arteriovenous grafts. Trans Am Soc Artif Intern Organs. 1988; 34: 519–523.
23. GuptaB. Textile physics of vascular grafts: compliance mismatch. In: ChakféN., DurandB., eds. New technologies in vascular biomaterials: connecting biomaterials to arterial structures. Strasbourg: Editions Europrot; 2009: 23–46.
24. 10.1016/j.actbio.2010.05.00810.1016/j.actbio.2010.05.008 ↗
25. International Organization for Standardization. ISO/DIS 7198: 1998 Cardiovascular implants – tubular vascular prostheses. ISO/DIS 7198; 1998: 1–48.
26. DievalF., ChakféN., Cottin-BizonneS. Les tests mécaniques d'évaluation des prothèses vasculaires. Rev Eur Biotechnol. 2001; 22: 70–87.
27. 10.1016/j.avsg.2008.02.00110.1016/j.avsg.2008.02.001 ↗
28. ASTM. Standard practice for conditioning textiles for testing (D-1776-90). Philadelphia, PA: American Society for Testing and Materials; 1997: 483–485.
29. 10.1177/08853282990130040310.1177/088532829901300403 ↗
30. 10.1016/S1350-4533(02)00010-310.1016/S1350-4533(02)00010-3 ↗
31. 10.1016/j.actbio.2009.12.00710.1016/j.actbio.2009.12.007 ↗
32. 10.1002/(SICI)1097-4636(1999)48:3<235::AID-JBM6>3.0.CO;2-310.1002/(SICI)1097-4636(1999)48:3<235::AID-JBM6>3.0.CO;2-3 ↗
33. 10.1016/j.biomaterials.2005.08.02910.1016/j.biomaterials.2005.08.029 ↗
34. 10.1016/0142-9612(86)90029-310.1016/0142-9612(86)90029-3 ↗
35. KidsonI.G. The effect of wall mechanical properties on patency of arterial grafts. Ann R Coll Surg Engl. 1983; 65(1): 24–29.
36. 10.1016/j.actbio.2010.01.01310.1016/j.actbio.2010.01.013 ↗
37. 10.1002/(SICI)1097-4636(1999)48:4<546::AID-JBM22>3.0.CO;2-V10.1002/(SICI)1097-4636(1999)48:4<546::AID-JBM22>3.0.CO;2-V ↗
38. WhiteR.A., KleinS.R., ShorsE.C. Preservation of compliance in a small diameter microporous, silicone rubber vascular prosthesis. J Cardiovasc Surg (Torino). 1987; 28(5): 485–490.
39. 10.1016/0142-9612(93)90068-D10.1016/0142-9612(93)90068-D ↗
40. 10.1046/j.1365-2168.2000.01566.x10.1046/j.1365-2168.2000.01566.x ↗
41. 10.1080/0040516860868890210.1080/00405168608688902 ↗
42. 10.1080/0040500070167958210.1080/00405000701679582 ↗
43. 10.1016/0021-9290(79)90039-310.1016/0021-9290(79)90039-3 ↗