journal article·2012-12-10Open access

Tidal Water Effect on the Hybrid Cathodic Protection Systems for Marine Concrete Structures

Jin-A Jeong, Chung-Kuk Jin, Won-Sub Chung

Abstract

This paper represents the behaviors of hybrid cathodic protection (hybrid CP) system in a reinforced concrete column specimen. Cathodic protection (CP) is widely used as a means of protecting corrosion for marine concrete structures such as harbor and offshore facilities. Specifically, hybrid CP, which is the combination both sacrificial anode cathodic protection (SACP) system and impressed current cathodic protection (ICCP) system, can be an optimum way to protect corrosion. Some complex concrete structures as well as harbor constructions are considered to be protected by both systems. Especially, it becomes more complicated to protect corrosion damage of concrete structures in the tidal and splash zones of marine environment. In case of Yellow Sea of the South Korea, the tidal zone reaches to 6-8m. On the condition that this system is well applied in the Yellow Sea, it is expected to show a good CP behavior to solve an underprotection problem, especially in tidal and splash zones. In this study, the hybrid system installed both the ICCP with Timesh anode and the SACP with zinc anode has been adopted to verify the current influence through laboratory experiment. CP potential and current have been investigated, in addition, 4-hour depolarization test has been involved to reveal the effectiveness of hybrid CP.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Corrosion Behavior and Inhibition · Infrastructure Maintenance and Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Sea Training Center, Korea Maritime University, Busan, Korea.

Department of Marine System Engineering, Korea Maritime University, Busan, Korea.

Department of Material Engineering, Pusan National University, Busan, Korea.

References (13)

Show source-provided references
1. Broomfield, J. P., (2007). “Corrosion of steel in concrete.” 2nd ed. London and New York: Taylor & Francis.
2. Bertolini, L. and Redaelli, E., (2009). “Throwing power of cathodic prevention applied by means of sacrificial anodes to partially submerged marine reinforced concrete piles: Result of numerical simulations.” Corrosion Science, 51(9), 2218-2230.10.1016/j.corsci.2009.06.012 ↗
3. Bertolini, L., Gastaldi, M., Pedeferri, M. and Redaelli, E., (2002). “Prevention of steel corrosion in concrete exposed to seawater with submerged sacrificial anodes.” Corrosion Science, 44, 1497-1513.10.1016/S0010-938X(01)00168-8 ↗
4. Kouril, M., Novak, P. and Bojko, M., (2010). “Threshold chloride concentration for stainless steels activation in concrete pore solutions.” Cement and Concrete Research, 40(3), 431-436.10.1016/j.cemconres.2009.11.005 ↗
5. Funahashi, M. and Young, W. T., (1997). “Three year performance of aluminum alloy galvanic cathodic protection system.” NACE International, 550, 1-16.
6. Kranc, S. C. Sagues, A. A. and Presuel-Moreno, F. J., (1997). “Computational and experimental investigation of cathodic protection distribution in reinforce concrete marine piling.” NACE International, 231, 1-12.
7. NACE International SP0169, (2007). “Control of External Corrosion on Underground or Submerged Metallic Piping System.” Houston: the Standard of the National Association of Corrosion Engineers.
8. NACE International SP0290, (2007). “Impressed current cathodic protection of reinforcing steel in atmospherically exposed concrete structures.” Houston: the Standard of the National Association of Corrosion Engineers.
9. Nguyen, T. S. Lorente, S. and Carcasses, M., (2009). “Effect of environment temperature on the chloride diffusion though CEM-I and CEM-V mortars: an Experimental study.” Construction and Building Materials, 23(2), 795-803.10.1016/j.conbuildmat.2008.03.004 ↗
10. Presuel-Moreno F. J. Kranc, S. C. and Sagues, A. A., (2005). “Cathodic prevention distribution in partially submerged reinforced concrete.” Corrosion, 61(6), 548-558.10.5006/1.3278190 ↗
11. Raupach, M., Elasense, B. and Polder, R., (2007). “Corrosion of reinforcement in concrete.” Cambridge: European Federation of Corrosion Publications.10.1533/9781845692285 ↗
12. Rincón, O. T. de, Hernández-López, Y., Valle-Moreno, A. de, Torres-Acosta, A. A., Barrios, F., Montero, P., Oidor-Salinas, P. and Montero, J. R., (2008). “Environmental influence on point anodes performance in reinforced concrete.” Construction and Building Materials, 22(4), 494-503.10.1016/j.conbuildmat.2006.11.014 ↗
13. Sagues, A. A. and Powers, R. G., (1995). “Sprayed-zinc sacrificial anodes for reinforced concrete in marine service.” NACE International, 515, 1-23.