journal article·2017-06-30Open access

Relationship of Apparent Electrical Resistivity Measured by Four-Probe Method with Water Content Distribution in Concrete

Hiroshi Minagawa, Shintaro Miyamoto, Makoto Hisada

Abstract

The electrical resistivity of concrete is an important value for designing electrochemical anti-corrosive methods or a durability indicator of reinforced concrete structures. It is well known that the four-probe method (the Wenner method) can be useful one for non-destructive evaluation of electrical resistivity. However, it has been pointed out that the measured results must be identified as an apparent value including the effect of water content gradient in concrete. In order to consider the engineering property of apparent electrical resistivity, this study evaluated the water content gra-dient dependency of the measured results by experimental approach and numerical analysis with FEM. As a result, this study explained the mechanism about the probe spacing dependency of apparent electrical resistivity of concrete with water content gradient in depth direction. Moreover, it was pointed out that the apparent electrical resistivity of con-crete with water content gradient was correlated with the electrical resistivity at a depth about equal to the probe spac-ing, and measuring apparent electrical resistivity does not necessarily mean that the four probe method can evaluate the electrical resistivity of the immediate surface of concrete in dry conditions. In addition to this, it was recommended to compare the apparent electrical resistivities measured by several distance of the probe spacing in order to clarify the presence or absence of the effect of the water content gradient in concrete.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Concrete and Cement Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering, Tohoku University, Sendai, Japan.

References (19)

Show source-provided references
1. 1) Andrade, C., (1993). “Calculation of chloride diffusion coefficients in concrete from ionic measurement.” Cement and Concrete Research, 23, 724-742.10.1016/0008-8846(93)90023-3 ↗
2. 2) Andrade, C., (2005). “Model for prediction of reinforced concrete service life based on electrical resistivity.” IBRACON Materials Journal, 1(1), 61-65.
3. 3) Andrade, C. and D’Andrea, C., (2010). “The use of electrical resistivity as a NDT for the specification of concrete durability.” In: Proceedings of the 6th International Conference on Concrete under Severe Conditions, 1, 195-200.10.1201/b10552-22 ↗
4. 4) Andrade, C. and Bolzoni, F., (2011). “Analysis of the relation between water and resistivity isotherms in concrete.” Material and Corrosion, 62(2), 130-138.10.1002/maco.201005777 ↗
5. 5) BRE, (1998). “Corrosion of reinforcement in concrete: electrochemical monitoring.” Digests 434.
6. 6) Castellote, M., Andrade, C. and Alonso, M. C., (2002). “Standardization of electrical resistivity for mortars and concrete in saturated or isolated conditions.” ACI Materials Journal, 99(2), 119-128.
7. 7) Gowers, K. R. and Millard, S. G., (1999). “Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique.” ACI Materials Journal, September-October, 536-541.
8. 8) Lopez,L. and Gonzalez, J. A., (1993). “Influence of the degree of pore saturation on the resistivity of concrete and the corrosion rate steel reinforcement.” Cement and Concrete Research, 23, 368-376.10.1016/0008-8846(93)90102-F ↗
9. 9) Lu, X., (1997). “Application of the Nernst-Einstein equation to concrete.” Cement and Concrete Research, 27(2), 293-302.10.1016/S0008-8846(96)00200-1 ↗
10. 10) Minagawa, H. and Hisada, M., (2010). “Influence of patch repair material on electrochemical desalination of concrete.” Journal of Advanced Concrete Technology, 8(3), 281-290.10.3151/jact.8.281 ↗
11. 11) Minagawa, H. and Hisada, M., (2013). “Consideration about chloride ion diffusion coefficient estimated by electric resistivity of concrete exposed in tidal zone.” In: 3rd International Conference on Sustainable Construction Materials and Technologies - SCMT3, M2-1(H-2).
12. 12) Minagawa, H., Yano T. and Hisada, M., (2013), “Effect of water content distribution due to drying condition on measuring results of electrical resistivity by four probes method.” Proceedings of the Japan Concrete Institute, 35(1), 1111-1116. (in Japanese)
13. 13) Nadelman, E. I. and Kurtis, K. E., (2014). “A resistivity-based approach to optimizing concrete performance - Surface resistivity is related to binder composition and microstructure.” Concrete International, May 2014, 50-54.
14. 14) Polder, R., Andrade, C., Elsener, B., Vennesland, Ø., Gulikers, J., Weidert, R. and Raupach, M., (2000). “RILEM TC 154-EMC: Electrochemical techniques for measuring metallic corrosion, test methods for on site measurement of resistivity of concrete.” Materials and Structures, 33, 603-611.10.1007/BF02480599 ↗
15. 15) Saleem, M., Shameem, M., Hussain, S. E. and Maslehuddin, M., (1996). “Effect of moisture, chloride and sulphate contamination on the electrical resistivity of portland cement concrete.” Construction and Building Materials, 10(3), 209-214.10.1016/0950-0618(95)00078-X ↗
16. 16) Sengul, O. and Gjørv, E. O., (2008). “Electrical resistivity measurements for quality control during concrete construction.” ACI Materials Journal, 105(6), 541-547.
17. 17) Shi, M., Chen, A. and Sun, J., (1999). “Determination of chloride diffusivity in concrete by AC impedance spectroscopy.” Cement and Concrete Research, 29(7), 1111-1115.10.1016/S0008-8846(99)00079-4 ↗
18. 18) Streicher, P., E. and Alexander, M., G., (1995). “A chloride conduction test for concrete.” Cement and Concrete Research, 25(6), 1284-1294.10.1016/0008-8846(95)00121-R ↗
19. 19) Teng, S., Divsholi, B. S., Lim, T. Y. D. and Gjørv, O. E., (2014). “Concrete with very high resistance to chloride ingress.” Concrete International, May, 30-36.