Advanced Computational Methods versus Analytical and Empirical Solutions for Determining Restraint Stresses in Bottom-Restrained Walls
Source abstract
Abstract
The distribution of restraint stresses in bottom-restrained walls is an important information for the efficient crack control of wall-like concrete members. Practical examples are retaining walls, bridge abutment walls or tank walls, for which the results can be used in order to assess the risk and intensity of harmful separating cracks over the wall height.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Underground Structures · Concrete Corrosion and Durability · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Structural Concrete, Graz University of Technology, Graz, Austria.
Department of Concrete Structures and Bridges, Slovak University of Technology in Bratislava, Bratislava, Slovakia.
References (25)
Show source-provided references
1. 1) ACI, (2007). “Report on thermal and volume change effects on cracking of mass concrete.” Farmington Hills: American Concrete Institute. ACI 207.2R-07.
2. 2) Bamforth, P. B., (2017). “CIRIA C766: Control of cracking caused by restrained deformation in concrete.” London: CIRIA.
3. 3) BAW Bulletin, (2011). “Crack width limitation for restraint stresses at early age in massive hydraulic structures.” Karlsruhe: Federal Waterways Engineering and Research Institute, Edition 2011. (in German)
4. 4) BAW Bulletin, (2019, in press). “Crack width limitation for restraint stresses in massive hydraulic structures.” Karlsruhe: Federal Waterways Engineering and Research Institute, Edition 2019. (in German)
5. 5) COIN, (2011). “Basis for and practical approaches to stress calculations and crack risk estimation in hardening concrete structures.” Oslo: Building and Infrastructure 2011, COIN Project report 31.
6. 6) EN 1992-1-1, (2011). “Design of concrete structures, Part 1-1: General rules and rules for buildings.” Brussels: CEN.
7. 7) EN 1992-3, (2006). “Design of concrete structures, Part 3: Liquid retaining and containment structures” Brussels: CEN.
8. 8) Fairbairn, E. M. R. and Azenha, M., (2018). “Thermal cracking of massive concrete structures. State of the art report of the RILEM TC 254-CMS.” 1st ed. Springer.
9. 9) Heinrich, P., (2018). “Efficient consideration of viscoelastic properties for the determination of restraint stresses in restrained concrete members.” Thesis (PhD). Graz University of Technology. (in German)
10. 10) Jędrzejewska, A., Benboudjema, F., Lacarrière,, L., Azenha, M., Schlicke, D., Stefano, D. P., Delaplace, A., Granja, J., Hájková, K., Heinrich, P. J., Sciumè, G., Strieder, E., Stierschneider, E., Šmilauer, V. and Troyan, V., (2018). “COST TU1404 benchmark on macroscopic modelling of concrete and concrete structures at early age: Proof-of-concept stage.” Construction and Building Materials, 174, 173-189.10.1016/j.conbuildmat.2018.04.088 ↗
11. 11) JSCE, (2007). “Guidelines for concrete, 15: Standard specifications for concrete structures. Design.” Tokyo: Japan Society of Civil Engineers.
12. 12) Knoppik-Wróbel, A., (2015). “Analysis of early-age thermal–shrinkage stresses in reinforced concrete walls.” Thesis (PhD). Silesian University of Technology.
13. 13) Knoppik-Wróbel, A. and Klemczak, B., (2015). “Degree of restraint concept in analysis of early-age stresses in concrete walls.” Engineering Structures, 102, 369-386.10.1016/j.engstruct.2015.08.025 ↗
14. 14) Matiašková, L. and Šoltész, J., (2017). “Macroscopic calculation model for simulating early age behavior of concrete members.” In: Early Age Cracking and Serviceability in Cement-based Materials and Structures, Vol. 2, Brussels 12-14 of September 2017. RILEM Publications, 695-701.
15. 15) Nilsson, M., (2003). “Restraint factors and partial coefficients for crack risk analysis of early age concrete structures.” Thesis (PhD). Lulea University of Technology.
16. 16) ÖBV Bulletin, (2018). “Analytical design of watertight structures with optimized concrete.” Vienna: Austrian society for construction technology. (in German)
17. 17) Schlicke, D., (2014). “Minimum reinforcement for restrained concrete.” Thesis (PhD). Graz University of Technology. (in German)
18. 18) Schlicke, D. and Tue, N. V., (2010). “Measurement of thermal restraint in hardening mass concrete - a new approach exemplified by a thick foundation slab.” In: Proceedings of 6th Central European Congress on Concrete Engineering, Marianske Lazne 30 September - 1 October 2010. CCC2010. 179-184.
19. 19) Schlicke, D. and Tue, N. V., (2012). “Approach for consideration of viscoelasticity in time step FEM based restraint analyses of hardening concrete.” In: Proceedings of 1st International Conference on Numerical Modeling Strategies for Sustainable Concrete Structures, Ais-en-Provence 29 May - 1 June, 53.
20. 20) Schlicke, D. and Tue, N. V., (2013). “Consideration of viscoelasticity in time step FEM-based restraint analyses of hardening concrete.” Journal of Modern Physics, 4, 9-14.10.4236/jmp.2013.410A2002 ↗
21. 21) Schlicke, D. and Tue, N. V., (2014). “Minimum reinforcement for crack width control in restrained concrete members.” Structural Concrete, 16, 221-232.
22. 22) Schlicke, D., Tue, N. V., Klausen, A., Kanstad, T. and Bjøntegaard Ø., (2014). “Structural analysis and crack assessment of restrained concrete walls - 3D FEM-simulation and crack assessment.” In: Proceedings of the 1st Concrete Innovation Conference, Oslo 11-13 June 2014.
23. 23) Schlicke, D., Matiašková, L. and Šoltész, J., (2018). “Effect of partial restraining conditions and Poisson's ratio in bottom-restrained walls.” In: Proceedings of International Conference on Interdisciplinary Approaches for Cement-based Materials and Structural Concrete (SynerCrete'18), Vol. 2, Funchal 24-26 October 2018. Paris: RILEM Publications, 573-578.
24. 24) Turner, K., (2017). “A holistic approach for determining the minimum reinforcement for jointless hydraulic structures.” Thesis (PhD). Graz University of Technology. (in German)
25. 25) Zych M., (2018). “Degree of external restraint of wall segments in semi-massive reinforced concrete tanks: Part I rectangular segments.” Structural Concrete, 19, 820-828.10.1002/suco.201700036 ↗