The effectiveness of a commercially available sacrificial point anode for corrosion prevention of steel in cracked concrete is presented. Reinforced concrete prisms with dimensions of 150 mm x 150 mm x 500 mm were prepared with a water to cement ratio (W/C) of 0.4 showing crack widths ranging from 0.1 to 0.4 mm obtained by pre-cracking. These specimens were exposed to three conditions: (1) laboratory air (temperature of 20±2°C and relative humidity of 60%); (2) immersed in 3% NaCl solution; and (3) dry/wet cycles of above mentioned conditions. Measurements included the free corrosion potential, polarization behavior of the sacrificial point anode, anodic-cathodic polarization curve of the reinforcement steel and visual observation. The test results show that the sacrificial point anode was effective to prevent the embedded steel from corrosion in cracked concrete. Specimens exposed to dry/wet cycles or immersed in 3% NaCl solution demonstrated a better protection than those exposed to laboratory air due to the high moisture condition. Thus, a sacrificial point anode becomes active to protect the steel bars even in cracked concrete.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Graduate School of Engineering, Kyushu University, Fukuoka, Japan.
Department of Civil Engineering, Kyushu University, Fukuoka, Japan.
Department of Civil Engineering, Hasanuddin University, Makassar, Indonesia.
References (20)
Show source-provided references
1. 1) ACI 224.1R-07, (2009). “Control of cracking in concrete structures.” American Concrete Institute, Detroit.
2. 2) ACI 318-08, (2008). “Building code requirements for structural concrete.” American Concrete Institute, Farmington Hills.
3. 3) ASTM C 876-09, (2009). “Standard test method for corrosion potentials of uncoated reinforcing steel in concrete.” West Conshohocken, PA: American Society of Testing and Materials.
4. 4) Bertolini, L., Bolzoni, F., Cigada, A., Pastore, T. and Pedeferri, P., (1993). “Cathodic protection of new and old reinforced concrete structures.” Corrosion Science, 35, 1633-1639.10.1016/0010-938X(93)90393-U ↗
5. 5) BS 8110-2, (1985). “Structural use of concrete – Part 2: Code of practice for special circumstances.” London: British Standard Institution.
6. 6) Collepardi, M., Fratesi, R., Moriconi, G., Coppola, L. and Corradetti, C., (1990). “Use of nitrite salt as corrosion inhibitor admixture in reinforced concrete structures immersed in sea-water.” In: E.Vazquez Ed. Admixture for concrete – improvement of properties. Chapman and Hall, London, 279-288.
7. 7) Concrete Library 107, (2011). “Recommendation for design and construction of electrochemical corrosion control method.” Japan Society of Civil Engineers, Tokyo, 67-68.
8. 8) DENKA, (2011). “Galvashield XP catalogs.” Denki Kagaku Kogyo Kabushiki Kaisha Co., Ltd, Niigata. (in Japanese)
9. 9) Dugarte, M. J. and Sagues, A. A., (2014). “Sacrificial point anode for cathodic prevention of reinforcing steel in concrete repairs: Part 1 – Polarization behavior.” Corrosion, NACE International, Houston, 70(3), 303-317.10.5006/1016 ↗
10. 10) Fratesi, R., Collepardi, M. and Moriconi, G., (1992). “Cathodic protection of cracked reinforced concrete structures under sea water.” In: Proceedings of Innovative Marine Materials and Technologies, La Spezia, Italy.
11. 11) IS 456:2000, (2005). “Code of practice for plain and reinforced concrete.” New Delhi: Bureau of Indian Standard.
12. 12) JSCE, (1986). “Standard specification for design and construction of concrete structures.” Publication SP-1, Part 1 (Design), Tokyo: Japan Society of Civil Engineers.
13. 13) Nmai, C. K. and Attiogbe, E. K., (1982). “Effect of chemical and mineral admixture on the corrosion of steel in concrete.” CORROSION/92, NACE, 201.
14. 14) Ohno, Y., Praparntanatorn, S. and Suzuki, L., (1996). “Influence of cracking and water cement ration on macrocell corrosion of steel in concrete.” In: C. L. Page, P. B. Bamforth and J. W. Figg, Eds. Corrosion of reinforcement in concrete construction, The Royal Society of Chemistry, 88-104.
15. 15) Okada, K. and Miyagawa, T., (1980). “Chloride corrosion of reinforcing steel in cracked concrete.” In: V. M. Malhotra, ed. Performance of concrete in marine environment, SP-65, ACI, 237-254.
16. 16) Otsuki, N., (1985). “A study of effectiveness of chloride on corrosion of steel bar in concrete.” Report of Port and Harbor Research Institute (PHRI), Japan, 127-134.
17. 17) Pedeferri, P., (1996). “Cathodic protection and cathodic prevention.” Construction and Building Materials, 10(5), 391-402.10.1016/0950-0618(95)00017-8 ↗
18. 18) Rincon, O. T., Lopez, Y. H., Moreno, A. V., Acosta, A. T., Barrios, F., Montero, P., Salinas, P. O. and Montero, J. R., (2008). “Environmental influence on point anode performance in reinforced concrete.” Construction and Building Materials, 22, 494-503.10.1016/j.conbuildmat.2006.11.014 ↗
19. 19) Saraswathy, H. and Wong Song, H., (2007). “Corrosion monitoring of reinforced concrete structure: A review.” International Journal of Electrochemical Science, 2, 1-28.
20. 20) Suzuki, L., Ohno, Y., Praparntanatorn, S. and Tamura, H., (1990). “Mechanism of steel corrosion in cracked concrete, corrosion of reinforcement in concrete.” In: C. L. Page, K. Treadaway and P. Bamforth, Eds. London, Society of Chemical Industry, 19-28.