Influence of Applied Loads on the Permeability Behavior of Ultra High Performance Concrete with Steel Fibers
Source abstract
Abstract
Ultra high performance concrete (UHPC) with steel fibers not only possesses the higher compressive strength can be up to above 100MPa, but also has better tensile strength and ultimate strain because of the addition of steel fibers compared with ordinary concrete. However, the permeability behavior of UHPC is frequently ignored in the durability dsign or repair, especially for that with a mass of cracks after suffering short-lived vibration, shock or explosion. This paper is developed to investigate the permeability behavior of UHPC after suffering tensile and compressive loadings, and the water as well as chloride permeability are determined. The results show applied tensile and compressive loadings increase the water and chloride permeability of UHPC. Particularly for the UHPC after suffering high loading damage, the increase of permeability becomes more obvious. Self-healing treatment is also applied to the UHPC with loading damage, and the permeability resistance of UHPC is improved by the treatment of self-healing, which provides an effective method to repair the UHPC with loading damage. In addition, the relation between permeability behavior and applied loads or cracks development are established in this paper, which can be used to evaluate the permeability behavior of UHPC suffered loading damage.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Innovative concrete reinforcement materials · Concrete and Cement Materials Research · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Structural Engineering, Tongji University, Shanghai, China.
College of Civil Engineering, Qingdao University of Technology, Qingdao, China.
References (32)
Show source-provided references
1. 1) ASTM, (2008). “Standard test method for water-soluble chloride in mortar and concrete. C1218-99.” West Conshohocken, 2008, PA.
2. 2) Aldea, C. M., Shah, S. P. and Karr, A., (1999). “Effect of crack on water and chloride permeability of concrete.” Journal of Materials in Civil Engineering, 11, 181-187.10.1061/(ASCE)0899-1561(1999)11:3(181) ↗
3. 3) Charron, J. P., Denarié, E. and Brühwiler, E., (2008). “Transport properties of water and glycol in an ultra high performance fibers reinforced concrete (UHPC) under high tensile deformation.” Cement and Concrete Research, 38, 689-698.10.1016/j.cemconres.2007.12.006 ↗
4. 4) Collins, M. P., Mitchell, D. and MacGregor, J. G., (1993). “Structural design considerations for high-strength concrete.” Concrete International, 15.
5. 5) Granger, S., Loukili, A., Pijaudier-Cabot, G. and Chanvillard, G., (2007). “Experimental characterization of the self-healing of cracks in an ultra high performance cementitious material: mechanical tests and acoustic emission analysis.” Cement and Concrete Research, 37, 519-527.10.1016/j.cemconres.2006.12.005 ↗
6. 6) Hassan, A. M. T., Jones, S. W. and Mahmud, G. H., (2012). “Experimental test methods to determine the uniaxial tensile and compressive behavior of ultra high performance fiber reinforced concrete (UHPC).” Construction and Building Materials, 37, 874-882.10.1016/j.conbuildmat.2012.04.030 ↗
7. 7) Habel, K., Viviani, M., Denarié, E. and Brühwiler, E., (2006). “Development of the mechanical properties of an ultra-high performance fiber reinforced concrete (UHPFRC).” Cement and Concrete Research, 36, 1362-1370.10.1016/j.cemconres.2006.03.009 ↗
8. 8) Homma, D., Mihashi, H. and Nishiwaki, T., (2009). “Self-Healing Capability of Fibre Reinforced Cementitious Composites.” Journal of Advanced Concrete Technology, 7, 217-228.10.3151/jact.7.217 ↗
9. 9) JTJ, (1998). “Testing code of concrete for port and waterway engineering.” JTJ270.
10. 10) Kan, L. L. and Shi, H. S., (2012). “Investigation of self-healing behavior of engineered cementitious composites (ECC) materials.” Construction and Building Materials, 29, 348-356.10.1016/j.conbuildmat.2011.10.051 ↗
11. 11) Kang, S. T., Yun, L., Park, Y. D. and Kim, J. K., (2010). “Tensile fracture properties of an ultra high performance fiber reinforced concrete (UHPFRC) with steel fiber.” Composite Structures, 92, 61-71.10.1016/j.compstruct.2009.06.012 ↗
12. 12) Kelham, S. A., (1998). “A water absorption test for concrete.” Magazine of Concrete Research, 40, 106-110.
13. 13) Li, V. C. and Maalej, M., (1996). “Toughening in cement based composites. Part II: Fibers reinforced cementitious composites.” Cement and Concrete Composites, 18, 239-249.
14. 14) Li, V. C., Wang, S. and Wu C., (2001). “Tensile strain-hardening behavior of polyvinyl alcohol engineered cementitious composite (PVA-ECC).” ACI Materials Journal, 98, 483-492.
15. 15) Loo, Y. H., (1992) “A new method for microcrack evaluation in concrete under compression.” Materials and Structures, 25, 573-578.10.1007/BF02472225 ↗
16. 16) Marcotte, T. D. and Hansson, C. M., (2007). “Corrosion products that form on steel within cement paste.” Materials and structures, 40, 325-340.10.1617/s11527-006-9170-4 ↗
17. 17) Moranville, V. M. M., (1998). “The leaching of the reactive powder concretes: results on transfer properties.” MRS Proceedings, 503. Boston, MA, USA, 145-150.
18. 18) Park, S. H., Dong, J. K., Ryu, G. S. and Koh, K. T., (2012). “Tensile behavior of ultra high performance hybrid fiber reinforced concrete.” Cement and Concrete Composites, 34, 172-184.10.1016/j.cemconcomp.2011.09.009 ↗
19. 19) Rabehi, B., Ghernouti, Y., Boumchedda, K., Li, A. and Drir, A., (2016). “Durability and thermal stability of ultra high-performance fibre-reinforced concrete (UHPFRC) incorporating calcined clay.” European Journal of Environmental and Civil Engineering, 1-18.
20. 20) Reda, M. M., Shrive, N. G. and Gillott, J. E., (1999). “Microstructural investigation of innovative UHPC.” Cement and Concrete Research, 29, 323-329.10.1016/S0008-8846(98)00225-7 ↗
21. 21) Roux, N., (1996). “Experimental study of durability of reactive powder concretes.” Journal of Materials in Civil Engineering, 8, 1-6.10.1061/(ASCE)0899-1561(1996)8:1(1) ↗
22. 22) Şahmaran, M. and Li, V. C., (2009). “Influence of microcrack on water absorption and sorptivity of ECC.” Materials and Structures, 42, 593-603.10.1617/s11527-008-9406-6 ↗
23. 23) Simčič, T., Pejovnik, S., Schutter, G. D. and Bosiljkov, V. B., (2015). “Chloride ion penetration into fly ash modified concrete during wetting-drying cycles.” Construction and Building Materials, 93, 1216-1223.10.1016/j.conbuildmat.2015.04.033 ↗
24. 24) Toutlemonde, F., Bouteiller, V., Platret, G., Carcasses, M., Lion, M. and Toutlemonde, F., (2010). “Field demonstration of UHPFRC durability.” Concrete International. 32, 39-45.
25. 25) Wang, H., Lu, C., Jin, W. and Bai, Y., (2011). “Effect of external loads on chloride transport in concrete.” Journal of Materials in Civil Engineering, 23, 1043-1049.10.1061/(ASCE)MT.1943-5533.0000265 ↗
26. 26) Wang, K., Jansen, D. C., Shah, S. P. and Karr, A. F., (1997). “Permeability study of cracked concrete.” Cement and Concrete Research, 27, 381-393.10.1016/S0008-8846(97)00031-8 ↗
27. 27) Wang, L. and Li, S. H., (2014). “Capillary absorption of concrete after mechanical loading.” Magazine of Concrete Research, 66, 420-431.10.1680/macr.13.00331 ↗
28. 28) Wang, W., Liu, J., Agostini, F., Davy, C. A., Skoczylas, F. and Corvez, D., (2014). ”Durability of an ultra high performance fiber reinforced concrete (UHPFRC) under progressive aging.” Cement and Concrete Research, 55, 1-13.10.1016/j.cemconres.2013.09.008 ↗
29. 29) Yang, S. L., Millard, S. G., Soutsos, M. N., Barnett, S. J. and Le, T. T., (2009).“Influence of aggregate and curing regime on the mechanical properties of ultra-high performance fibre reinforced concrete (UHPFRC).” Construction and Building Materials, 23, 2291-2298..10.1016/j.conbuildmat.2008.11.012 ↗
30. 30) Yi, N. H., Kim, J. H. J., Han, T. S., Cho, Y. G. and Lee, J. H., (2012). “Blast-resistant characteristics of ultra-high strength concrete and reactive powder concrete.” Construction and Building Materials, 28, 694-707.10.1016/j.conbuildmat.2011.09.014 ↗
31. 31) Yu, R., Spiesz, P. and Brouwers, H. J. H., (2015). “Development of ultra-high performance fibre reinforced concrete (UHPC): Towards an efficient utilization of binders and fibres.” Construction and Building Materials, 79, 273-282.10.1016/j.conbuildmat.2015.01.050 ↗
32. 32) Zhang, L., Jia, J., Meng, G. and Zhu, W. (2014). “Chloride diffusion in concrete subjected to compressive loading.” Magazine of Concrete Research, 66(19), 991-997.10.1680/macr.14.00048 ↗