journal article·2017-10-31Open access

The Effect of Water-to-Cement Ratio and Curing on Material Properties of Mortar Specimens in Stray Current Conditions

Agus Susanto, Dessi A. Koleva, Klaas van Breugel

Abstract

This work reports on the synergetic effect of water-to-cement ratio, curing conditions, varying external environment and stray current on the microstructural (porosity and pore size), electrical (resistivity) and mechanical (compressive strength) properties of 28 days-cured cement-based materials. The influence of curing on porosity and pore size, in stray current conditions, was assessed by correlating the performance of 28 days cured mortar with that of fresh (24h-cured only) mortar specimens in identical environmental medium.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Concrete and Cement Materials Research · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Civil Engineering and Geosciences, Materials and Environment, Delft University of Technology, Delft, The Netherlands.

Delft University of Technology, Faculty of Civil Engineering and Geosciences, Materials and Environment, Delft, The Netherlands.

References (41)

Show source-provided references
1. 1) ACI Committee, (1982). “Hot weather concreting.” ACI 305R-77, ACI, Detroit, Mich.
2. 2) ACI Committee, (1981). “Standard practice for curing concrete.” ACI 308-81, ACI, Detroit, Mich.
3. 3) Al-Ani, S. H., Mokdad, A. and Al Zaiwary, K., (1988). “The effect of curing delay on concrete in hot weather.” Materials and Structures, 21(3), 205-212.10.1007/BF02473057 ↗
4. 4) Andrade, C., Alonso, C., Arteaga, A. and Tanner, P., (2000). “Methodology based on the electrical resistivity for calculation of reinforcement service life.” Fifth CANMET/ACI International Conference, 899-915.
5. 5) Andrade, C., Castellote, M. and d’Andrea, R., (2011). “Chloride aging factor of concrete measured by means of resistivity.” Proceedings of the XII-international conference on durability of building materials and components, Porto, Portugal.
6. 6) Archie, G. E., (1942) “The electrical resistivity log as an aid in determining some reservoir characteristics.” Transactions of the American Institute of Mining and Metallurgical Engineers, 146, 54-62.10.2118/942054-G ↗
7. 7) Atkins, P. W., (1990). “Physical chemistry” Oxford: Oxford University Press.
8. 8) Aylott, P. J., Cotton, I. and Charalambous, C. A., (2013). “Impact and management of stray current on DC rail systems.” CHAPCIS Intertek, United Kingdom.10.1049/ic.2013.0087 ↗
9. 9) Bentz, D. P. and Garboczi, E. J., (1999). “Effects of cement particle size distribution on performance properties of Portland cement-based materials.” Cement and Concrete Research, 29(10), 1663-1671.10.1016/S0008-8846(99)00163-5 ↗
10. 10) Bertolini, L., Carsana, M. and Pedeferri, P., (2007). “Corrosion behaviour of steel in concrete in the presence of stray current.” Corrosion Science, 49(3), 1056-1068.10.1016/j.corsci.2006.05.048 ↗
11. 11) Bredenkamp, S., Kruger, D. and Bredenkamp, G. L., (1993). “Direct electric curing of concrete.” Magazine of Concrete Research, 45(162), 71-74.10.1680/macr.1993.45.162.71 ↗
12. 12) Castellote, M., Andrade, C. and d’Andréa, R., (2009). “The use of resistivity for measuring aging of chloride diffusion coefficient.” Proceedings RILEM TC 211-PAE International Conference - Concrete in Aggressive Aqueous Environments, Toulose.
13. 13) Charalambous, C. A. and Aylott, P., (2014). “Dynamic stray current evaluations on cut-and-cover sections of DC metro systems.” IEEE Transactions on Vehicular Technology, 63(8), 3530-3538.10.1109/TVT.2014.2304522 ↗
14. 14) Galsgaard, F. and Nielsen, L. V., (2006). “AC/DC interference corrosion in pipelines.” Summary Report by MetriCorr., The Danish Gas Technological Centre.
15. 15) Hewlett, P. C., (2003). “Lea’s chemistry of cement and concrete.” New York: John Wiley & Sons.
16. 16) Indian Standard, (2000). “Plain & reinforced concrete-Code of practice.” IS 456: 4th revision, p. 27.
17. 17) Katz, A. J. and Thompson, A. H., (1986) “Quantitative prediction of permeability in porous rock.” Physical Review. B, 34, 8179-8181.10.1103/PhysRevB.34.8179 ↗
18. 18) Koleva, D. A., Hu, J., Fraaij, A. L. A., Stroeven, P., Boshkov, N. and van Breugel, K., (2006). “Cathodic protection revisited: Impact on structural morphology sheds new light on its efficiency.” Cement and Concrete Composites, 28(8), 696-706.10.1016/j.cemconcomp.2006.05.009 ↗
19. 19) Koleva, D. A., De Wit, J. H. W., van Breugel, K., Lodhi, Z. F. and Ye, G., (2007). “Investigation of corrosion and cathodic protection in reinforced concrete II. Properties of steel surface layers.” Journal of the Electrochemical Society, 154(5), C261-C271.
20. 20) Koleva, D. A., Guo, Z., van Breugel, K. and De Wit, J. H. W., (2009). “The beneficial secondary effects of conventional and pulse cathodic protection for reinforced concrete, evidenced by X‐ray and microscopic analysis of the steel surface and the steel/cement paste interface.” Materials and corrosion, 60(9), 704-715.10.1002/maco.200805155 ↗
21. 21) Koleva, D. A., Guo, Z., van Breugel, K. and de Wit, J. H. W., (2010). “Microstructural properties of the bulk matrix and the steel/cement paste interface in reinforced concrete, maintained in conditions of corrosion and cathodic protection.” Materials and corrosion, 61(7), 561-567.10.1002/maco.200905423 ↗
22. 22) Kurumisawa, K. and Nawa, T., (2016). “Electrical conductivity and chloride ingress in hardened cement paste.” Journal of Advanced Concrete Technology, 14(3), 87-94.10.3151/jact.14.87 ↗
23. 23) Lakshminarayanan, V., Ramesh, P. S. and Rajagopalan, S. R., (1992). “A new technique for the measurement of the electrical resistivity of concrete.” Magazine of Concrete Research, 44(158), 47-52.10.1680/macr.1992.44.158.47 ↗
24. 24) Lian, C., Zhuge, Y. and Beecham, S., (2011). “The relationship between porosity and strength for porous concrete.” Construction and Building Materials, 25(11), 4294-4298.10.1016/j.conbuildmat.2011.05.005 ↗
25. 25) McCarter, W. J., Butler, A., Chrisp, T. M., Emerson, M., Starrs, G. and Blewett, J., (2001). “Field trials on concrete monitoring sensors.” Proceedings of the Institution of Civil Engineers - Structures and Buildings, 146(3), 295-305.10.1680/stbu.2001.146.3.295 ↗
26. 26) Mehta, P. K. and Monteiro, P. J. M., (2001). “Concrete: Microstructure, properties and materials.” McGraw-Hill.
27. 27) Nehdi, M. and Soliman, A. M., (2011). “Early-age properties of concrete: overview of fundamental concepts and state-of-the-art research.” Proceedings of the Institution of Civil Engineers - Construction Materials, 164, 57-77.10.1680/coma.900040 ↗
28. 28) Neville, A. M., (1995). “Properties of concrete.” 4th and final Ed., London: Longman.
29. 29) Page, C. L., Short, N. R., Holden, W. R., (1986). “The influence of different cements on chloride-induced corrosion of reinforced steel.” Cement Concrete Research, 16, 79-86.10.1016/0008-8846(86)90071-2 ↗
30. 30) Powers, T. C., (1958). “The physical structure and engineering properties of concrete.” PCA Res. Dept. Bull., 90.
31. 31) Ritter, H. L. and Drake, L. C., (1945). “Pore-size distribution in porous materials, Pressure porosimeter and determination of complete macropore-size distributions.” Industrial and Engineering Chemistry, 17, 782-786.
32. 32) Roy, D. M. and Idorn, G. M., (1993). “Concrete microstructure.” Strategic Highway Research Program, National Research Council, Washington, DC.
33. 33) Sahu, S., Badger, S., Thaulow, N. and Lee, R. J., (2004). “Determination of water–cement ratio of hardened concrete by scanning electron microscopy.” Cement & Concrete Composites, 26, 987-992.10.1016/j.cemconcomp.2004.02.032 ↗
34. 34) Susanto, A., Koleva, D. A., van Breugel, K. and van Beek, C., (2017). “Stray current-induced development of cement-based microstructure in water-submerged, Ca(OH)2-submerged and sealed conditions.” Journal of Advanced Concrete Technology, 15, 244-268.10.3151/jact.15.244 ↗
35. 35) Susanto, A., Koleva, D.A., Copuroglu, O., van Beek, C. and van Breugel, K., (2013). “Mechanical, electrical and microstructural properties of cement-based materials in conditions of stray current flow.” Journal of Advanced Concrete Technology, 11, 119-134.10.3151/jact.11.119 ↗
36. 36) Susanto, A., Koleva, D. A. and van Breugel, K., (2017). The influence of stray current on the maturity level of cement-based materials. In: Concrete Durability. Springer International Publishing, 57-82.10.1007/978-3-319-55463-1_4 ↗
37. 37) Troxell, G. E., Davis, H. E. and KelIy, J. W., (1968). “Composition and properties of concrete.” 2nd ed. New York: McGraw-Hill.
38. 38) Wang, K., Cable, J. K. and Zhi, G., (2002). “Investigation into improved pavement curing materials and techniques, Part 1 (Phases I and II).” Center for Portland Cement Concrete Pavement Technology, Iowa State University.
39. 39) Washburn, E. W., (1921). “The dynamics of capillary flow.” Physical Review, 17(3), 273-283.10.1103/PhysRev.17.273 ↗
40. 40) Ye, G., (2003). “Experimental study and numerical simulation of the development of the microstructure and permeability of cementitious materials.” Thesis (Ph.D.), Delft University of Technology.
41. 41) Kim, Y.-Y., Lee, K.-M., Bang, J.-W. and Kwon, S.-J., (2014). “Effect of W/C ratio on durability and porosity in cement mortar with constant cement amount.” Advances in Materials Science and Engineering, Vol. 2014, ID 273460.10.1155/2014/273460 ↗