journal article·2019-12Open access

Laboratory X-ray tomography for metal additive manufacturing: Round robin test

Anton du Plessis, Stephan G. le Roux, Jess Waller, Philip Sperling, Nils Achilles, Andre Beerlink, Jean-François Métayer, Mirko Sinico, Gabriel Probst, Wim Dewulf, Florian Bittner, Hans-Josef Endres, Marian Willner, Ágota Drégelyi-Kiss, Tomas Zikmund, Jakub Laznovsky, Jozef Kaiser, Pascal Pinter, Stefan Dietrich, Elena Lopez, Oliver Fitzek, Porebski Konrad

Abstract

Abstract This paper reports on the results of a round robin test conducted by ten X-ray micro computed tomography (micro-CT) laboratories with the same three selected titanium alloy (Ti6Al4V) laser powder bed fusion (L-PBF) test parts. These parts were a 10-mm cube, a 60-mm long and 40-mm high complex-shaped bracket, and a 15-mm diameter rod. Previously developed protocols for micro-CT analysis of these parts were provided to all participants, including suggested scanning parameters and image analysis steps. No further information on the samples were provided, and they were selected from a variety of parts from a previous different type of round robin study where various L-PBF laboratories provided identical parts for micro-CT analysis at one laboratory. In this new micro-CT round robin test which involves various micro-CT laboratories, parts from the previous work were selected such that each part had a different characteristic flaw type, and all laboratories involved in the study analyzed the same set of parts. The 10-mm cube contained subsurface pores just under its top surface (relative to build direction), and all participants could positively identify this. The complex bracket had contour pores around its outer vertical sides, and was warped with two arms deflected towards one another. Both of these features were positively identified by all participants. The 15-mm diameter rod had a layered stop/start flaw, which was also positively identified by all participants. Differences were found among participants for quantitative evaluations, ranging from no quantitative measurement made, to under and overestimation of the values in all analyses attempted. This round robin provides the opportunity to highlight typical causes of errors in micro-CT scanning and image analysis as applied to additively manufactured parts. Some workflow variations, sources of error and ways to increase the reproducibility of such analysis workflows are discussed. The ultimate aim of this work is to advance the efficient use of micro-CT facilities for process optimization and quality inspections for additively manufactured products. The results provide confidence in the use of laboratory micro-CT but also indicate the need for further development of standards, protocols and image analysis workflows for quantitative assessment, especially for direct and quantitative comparisons between different laboratories.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Additive Manufacturing Materials and Processes · Advanced X-ray and CT Imaging · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. Additive manufacturing of metallic components – process, structure and properties10.1016/j.pmatsci.2017.10.001 ↗
2. Materials for additive manufacturing10.1016/j.cirp.2017.05.009 ↗
3. Laser additive manufacturing of metallic components: materials, processes and mechanisms10.1179/1743280411Y.0000000014 ↗
4. Beautiful and functional: a review of biomimetic design in additive manufacturing
5. Todorov · 2014 · 2014
6. Dutton · 1620 · 2018
7. Process dependent porosity and the influence of shot peening on porosity morphology regarding selective laser melted AlSi10Mg parts
8. Fatigue properties of additively manufactured AlSi10Mg-surface treatment effect10.1016/j.prostr.2017.11.061 ↗
9. Using X-ray computed tomography to improve the porosity level of polyamide-12 laser sintered parts10.1016/j.cirp.2016.04.056 ↗
10. X-ray microcomputed tomography in additive manufacturing: a review of the current technology and applications
11. Overview of materials qualification needs for metal additive manufacturing10.1007/s11837-015-1810-0 ↗
12. ASTM E1570-11 · 2011
13. ASTM WK47031 · 2019
14. ISO/ASTM DTR 52905 · 2019 · 2019
15. Enhanced dimensional measurement by fast determination and compensation of geometrical misalignments of X-ray computed tomography instruments10.1016/j.cirp.2018.04.124 ↗
16. Towards geometrical calibration of x-ray computed tomography systems—a review10.1088/0957-0233/26/9/092003 ↗
17. Traceable porosity measurements in industrial components using X-ray computed tomography10.1115/1.4043192 ↗
18. Investigation of pore structure in cobalt chrome additively manufactured parts using X-ray computed tomography and three-dimensional image analysis
19. MethodsX standard method for microCT-based additive manufacturing quality control 1 : porosity analysis10.1016/j.mex.2018.09.005 ↗
20. MethodsX standard method for microCT-based additive manufacturing quality control 2 : density measurement10.1016/j.mex.2018.09.006 ↗
21. Standard method for microCT-based additive manufacturing quality control 3: surface roughness10.1016/j.mex.2018.09.004 ↗
22. Standard method for microCT-based additive manufacturing quality control 4: metal powder analysis10.1016/j.mex.2018.10.021 ↗
23. 2019