journal article·2026-06-26Open access

EFIB-Net: Information Bottleneck-Guided Multi-Resolution Attention Network for Robust ECG Denoising

Minghao Ma, Chen Liu, Yulin Mu, Jingqiu Chen, Li Zhu

Applied Sciences· Volume 16· Issue 13

Abstract

Wearable electrocardiogram (ECG) monitoring enables continuous cardiovascular assessment, yet signals acquired in ambulatory environments are inevitably corrupted by baseline wander, electrode motion artifacts, and muscle interference, which obscure diagnostically critical waveform features. Existing deep learning denoisers rely on heuristic attention mechanisms and time-domain-only losses, lacking principled control over what information the network retains or discards. To address this limitation, we propose EFIB-Net, an information bottleneck-guided multi-resolution network for robust ECG denoising. The framework introduces two complementary components: an efficient frequency-guided attention module that derives temporal attention weights directly from the energy distribution of parallel multi-resolution convolutional branches, requiring only four learnable parameters while providing physically interpretable feature selection that naturally highlights QRS complexes, and a variational information bottleneck constraint at the encoder–decoder bottleneck that forces the latent representation to retain only reconstruction-relevant information and discard noise, guided by a spectral–temporal composite loss. To the best of our knowledge, we are among the first to explicitly introduce the information bottleneck principle into deep-learning-based ECG signal denoising. Experiments on the MIT-BIH Arrhythmia Database show that EFIB-Net outperforms ten traditional and deep learning baselines across four standard metrics—signal-to-noise ratio (SNR), root mean square error, percentage root-mean-square difference, and correlation coefficient; at an input SNR of −5 dB it reaches 8.12 dB output SNR, surpassing the strongest attention-based competitor by 1.77 dB (p<0.01) while using only 0.45 M parameters and 10.8 ms inference latency per segment; downstream evaluation further demonstrates that the denoised signals achieve 99.18% R-peak detection sensitivity and 91.26% heartbeat classification F1-score, both within approximately one percentage point of the clean-signal upper bound, making it practical for real-time cardiac monitoring on resource-constrained wearable devices. Zero-shot cross-database evaluation on the QT Database further confirms generalizability, with only 0.54 dB degradation without retraining.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: ECG Monitoring and Analysis · Atrial Fibrillation Management and Outcomes · Cardiac electrophysiology and arrhythmias

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electronic Science and Engineering, Xi’an Jiaotong University, Xi’an 710049, China

Network Information Center, Xi’an Jiaotong University, Xi’an 710049, China

School of Information and Communication Engineering, Xi’an Jiaotong University, Xi’an 710049, China

School of Software Engineering, Xi’an Jiaotong University, Xi’an 710049, China

References (42)

Show source-provided references
1. ECG-based data-driven solutions for diagnosis and prognosis of cardiovascular diseases: A systematic review10.1016/j.compbiomed.2024.108235 ↗
2. Removal of motion artifacts in capacitive electrocardiogram acquisition: A review10.1109/TBCAS.2023.3270661 ↗
3. Escrivães, I., Lopes, D., Vilaça, J.L., Varela-Lema, L., and Morais, P. (2025). Evaluation of ECG waveform accuracy in the CardioBAN wearable device: An initial analysis. Appl. Sci., 15.10.3390/app152413143 ↗
4. Large-scale assessment of a smartwatch to identify atrial fibrillation10.1056/NEJMoa1901183 ↗
5. Lee, R., Kang, B., Kim, D., and Kim, D. (2026). Correlation based dynamic time warping for ECG waveform. Appl. Sci., 16.10.3390/app16052369 ↗
6. A lightweight residual dilated temporal transformer block for ECG classification on edge devices10.1038/s41598-026-35531-4 ↗
7. Cardiologist-level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network10.1038/s41591-018-0268-3 ↗
8. A foundational vision transformer improves diagnostic performance for electrocardiograms10.1038/s41746-023-00840-9 ↗
9. Learning ECG representations for multi-label classification of cardiac abnormalities
10. Anti-motion interference electrocardiograph monitoring system: A review10.1109/JSEN.2024.3383872 ↗
11. Multistage cascaded LMS adaptive FIR filter and its application to multiple artifacts removal from ECG10.1080/03772063.2025.2483934 ↗
12. Jia, Y., Pei, H., Liang, J., Zhou, Y., Yang, Y., Cui, Y., and Xiang, M. (2024). Preprocessing and denoising techniques for electrocardiography and magnetocardiography: A review. Bioengineering, 11.10.3390/bioengineering11111109 ↗
13. Stationary wavelet transform based ECG signal denoising method10.1016/j.isatra.2020.12.029 ↗
14. A new method based CEEMDAN for removal of baseline wander and powerline interference in ECG signals10.1016/j.ijleo.2020.165566 ↗
15. Power-line interference and baseline wander elimination in ECG using VMD and EWT10.1080/10255842.2023.2271608 ↗
16. Noise reduction in ECG signals using fully convolutional denoising autoencoders10.1109/ACCESS.2019.2912036 ↗
17. An ECG denoising method based on adversarial denoising convolutional neural network10.1016/j.bspc.2023.104964 ↗
18. Convolutional transformer-driven robust electrocardiogram signal denoising framework with adaptive parametric ReLU10.3934/mbe.2024189 ↗
19. Convolutional block attention autoencoder for denoising electrocardiograms10.1016/j.bspc.2023.105242 ↗
20. Attention-based convolutional denoising autoencoder for two-lead ECG denoising and arrhythmia classification10.1109/TIM.2022.3197757 ↗
21. Wang, S., and Li, L. (2025). TF-TransUNet1D: Time-frequency guided transformer U-Net for robust ECG denoising in digital twin. arXiv.10.1007/978-3-032-07694-6_9 ↗
22. Diagnostic-wise hybrid loss for ECG signals reconstruction based on wavelet decomposition
23. Tishby, N., Pereira, F.C., and Bialek, W. (2000). The information bottleneck method. arXiv.
24. Alemi, A.A., Fischer, I., Dillon, J.V., and Murphy, K. (2017, January 24–26). Deep variational information bottleneck. Proceedings of the 5th International Conference on Learning Representations (ICLR), Toulon, France.
25. A novel approach to enhancing biomedical signal recognition via hybrid high-order information bottleneck driven spiking neural networks10.1016/j.neunet.2024.106976 ↗
26. Design and implementation of a robust noise removal system in ECG signals using dual-tree complex wavelet transform10.1016/j.bspc.2020.102212 ↗
27. An efficient wavelet thresholding strategy and robust shrinkage approach for de-noising ECG signal10.1002/ima.23009 ↗
28. ECG signal denoising using an improved hybrid DWT-ADTF approach10.1007/s13239-023-00698-8 ↗
29. A deep-learning-based auto encoder-decoder model for denoising electrocardiogram signals10.1080/03772063.2024.2410428 ↗
30. Lin, H., Liu, R., and Liu, Z. (2023). ECG signal denoising method based on disentangled autoencoder. Electronics, 12.10.3390/electronics12071606 ↗
31. Shaheen, A., Ye, L., Karunaratne, C., and Seppänen, T. (2025). Fully-gated denoising auto-encoder for artifact reduction in ECG signals. Sensors, 25.10.3390/s25030801 ↗
32. Multichannel high noise level ECG denoising based on adversarial deep learning10.1038/s41598-023-50334-7 ↗
33. Qi, T., Zhang, H., Zhao, H., Shen, C., and Liu, X. (2024). Research on ECG signal classification based on hybrid residual network. Appl. Sci., 14.10.3390/app142311202 ↗
34. Xiao, Q., Lee, K., Mokhtar, S.A., Ismail, I., Pauzi, A.L.B.M., Zhang, Q., and Lim, P.Y. (2023). Deep learning-based ECG arrhythmia classification: A systematic review. Appl. Sci., 13.10.3390/app13084964 ↗
35. Di Paolo, Í.F., and Castro, A.R. (2024). Intra- and interpatient ECG heartbeat classification based on multimodal convolutional neural networks with an adaptive attention mechanism. Appl. Sci., 14.10.3390/app14209307 ↗
36. Convolutional autoencoder with sequential and channel attention for robust ECG signal denoising with edge device implementation10.1109/ACCESS.2025.3550949 ↗
37. The impact of the MIT-BIH arrhythmia database10.1109/51.932724 ↗
38. A noise stress test for arrhythmia detectors
39. A real-time QRS detection algorithm10.1109/TBME.1985.325532 ↗
40. Automatic classification of heartbeats using ECG morphology and heartbeat interval features10.1109/TBME.2004.827359 ↗
41. A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG
42. Olejarczyk, E., Sobieszek, A., and Assenza, G. (2024). Automatic detection of the EEG spike–wave patterns in epilepsy: Evaluation of the effects of transcranial current stimulation therapy. Int. J. Mol. Sci., 25.10.3390/ijms25169122 ↗