journal article·2026-06-25Open access

A Review of Stroboscopic and Phantom Array Effects in Light-Emitting Diode Lighting

Tianshu Chen, Alexander Herzog, Talita Schlichting, Tran Quoc Khanh

Applied Sciences· Volume 16· Issue 13

Abstract

The stroboscopic effect and phantom array effect caused by temporal light modulation (TLM) in light-emitting diode (LED) lighting are important temporal light artifacts (TLAs) that can influence visual perception, task performance, and visual comfort. This review systematically analyzes 40 studies published between 1998 and 2024 to provide a comprehensive overview of the current understanding of both effects. The reviewed literature covers visibility thresholds, influencing parameters, experimental methodologies, and assessment metrics. The analysis shows that reported visibility thresholds for the stroboscopic effect typically range from 550 to 1000 Hz, whereas thresholds for the phantom array effect may extend to 10–15 kHz, suggesting substantial differences in the underlying perceptual mechanisms. In addition to modulation frequency, modulation depth, waveform, duty cycle, luminance, retinal image motion, and observer factors have been identified as important determinants of visibility. The review further highlights significant methodological differences among studies, including variations in experimental design, stimulus generation, participant characteristics, and psychophysical procedures. Although the stroboscopic visibility measure (SVM) provides a standardized framework for evaluating the stroboscopic effect, no comparably validated metric is currently available for the phantom array effect. The review identifies major knowledge gaps regarding the interaction of influencing parameters and the lack of standardized assessment methods. Future research should focus on establishing unified experimental protocols and developing robust metrics for the phantom array effect to support comprehensive lighting standards that protect visual comfort, well-being, and consumer health.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular and Laser Science Research · Impact of Light on Environment and Health · Ergonomics and Musculoskeletal Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Laboratory of Adaptive Lighting Systems and Visual Processing, Technische Universität Darmstadt, 64289 Darmstadt, Germany

Syskron GmbH, Oskar-von-Miller-Straße 6b, 92442 Wackersdorf, Germany

References (78)

Show source-provided references
1. Wilkins, A., Veitch, J., and Lehman, B. (2010, January 12–16). LED lighting flicker and potential health concerns: IEEE standard PAR1789 update. Proceedings of the 2010 IEEE Energy Conversion Congress and Exposition, Atlanta, GA, USA.10.1109/ECCE.2010.5618050 ↗
2. (2015). IEEE Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers (Standard No. IEEE Std 1789-2015).
3. CIE (2016). Visual Aspects of Time-Modulated Lighting Systems–Definitions and Measurement Models, CIE TN.
4. Flicker: A review of temporal light modulation stimulus, responses, and measures10.1177/14771535211069482 ↗
5. Perspective—LED Flicker10.1149/2.0242001JSS ↗
6. LED Systems Applications and LED Driver Topologies: A Review10.1109/ACCESS.2023.3267673 ↗
7. Xu, X., Collin, A., Djokic, S.Z., Langella, R., Testa, A., and Drapela, J. (2017, January 26–29). Experimental evaluation and classification of LED lamps for typical residential applications. Proceedings of the 2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe), Torino, Italy.10.1109/ISGTEurope.2017.8260292 ↗
8. Solid-State Lighting: Toward Superior Illumination10.1109/JPROC.2005.853537 ↗
9. LEDs for Solid-State Lighting: Performance Challenges and Recent Advances10.1109/JSTQE.2009.2013476 ↗
10. Lifetime calculation of white HP-LEDs from 16,000 hours aging data
11. Monitoring the optical degradation of green light-emitting diodes on the basis of measured electrical characteristics10.1016/j.microrel.2021.114147 ↗
12. Steinbach, J., Gerspacher, A., Schlomann, B., Chassein, E., Emsmann, F., and Ashley-Belbin, N. (2019). Potential Für Energieeffiziente Beleuchtungssysteme in Unternehmen und Hemmnisse bei der Umsetzung, Fraunhofer ISI.
13. Gacio, D., Cardesin, J., Corominas, E.L., Alonso, J.M., Dalla-Costa, M., and Calleja, A. (2008, January 5–9). Comparison among power LEDs for automotive lighting applications. Proceedings of the 2008 IEEE Industry Applications Society Annual Meeting, Edmonton, AB, Canada.10.1109/08IAS.2008.259 ↗
14. Zissis, G., Bertoldi, P., and Serrenho, T. (2021). Update on the Status of LED-Lighting World Market Since 2018.
15. A Review of LED Drivers and Related Technologies10.1109/TIE.2017.2677335 ↗
16. Martinsons, C., Gaines, J., Vollers, J., Nachtrieb, R., Wolfman, H., and Zissis, G. (2022, January 1–3). Contemporary issues with temporal light modulation of lighting systems. Proceedings of the 2021 Joint Conference—11th International Conference on Energy Efficiency in Domestic Appliances and Lighting & 17th International Symposium on the Science and Technology of Lighting (EEDAL/LS:17), Toulouse, France.
17. A Review of Contemporary Issues with Temporal Light Modulation of Lighting Systems10.1109/TIA.2024.3425821 ↗
18. Kuiper, M., Källberg, S., Klej, A., Mantela, V., Thorseth, A., Zuber, R., Madias, E.N., Reiners, T., and Dekker, P. (2024, January 12–14). Interlaboratory Comparison On Traceable Flicker and Stroboscopic Effect Measurements Of Light Sources. Proceedings of the 2024 IEEE Sustainable Smart Lighting World Conference & Expo (LS24), Eindhoven, The Netherlands.10.1109/LS2463127.2024.10881444 ↗
19. PWM Series Dimming for Slow-Dynamics HPF LED Drivers: The High-Frequency Approach10.1109/TIE.2011.2130503 ↗
20. A hybrid modulation method for dimming in visible light communication
21. Tan, J. (2014). Investigation of Solutions to Minimize Flicker in LED Lighting, Rensselaer Polytechnic Institute.
22. Analyzing the past to prepare for the future: Writing a literature review10.2307/4132319 ↗
23. Phantom array and stroboscopic effects of a time-modulated moving light source during saccadic eye movement10.1177/1477153517693468 ↗
24. Effects of flicker characteristics from solid-state lighting on detection, acceptability and comfort10.1177/1477153511401983 ↗
25. Detection and acceptability of stroboscopic effects from flicker10.1177/1477153511414838 ↗
26. Tu, Y., Wang, L., Zhang, J., Lu, F., Liu, L., Perz, G., and Vogels, I. (2013, January 10–12). Cross-cultural similarities in the visibility of the stroboscopic effect. Proceedings of the 2013 10th China International Forum on Solid State Lighting (ChinaSSL), Beijing, China.
27. Modeling the visibility of the stroboscopic effect occurring in temporally modulated light systems10.1177/1477153514534945 ↗
28. 50.2: Invited paper: Stroboscopic effect of LED lighting10.1002/sdtp.10194 ↗
29. Polin, D. (2015). Flimmereffekte von Pulsweiten-Modulierter LED-Beleuchtung. [PhD Thesis, Technische Universität Darmstadt].
30. Influence of flicker characteristics on stroboscopic effects10.1177/1477153515599566 ↗
31. Reducing the stroboscopic effects of LED luminaires with pulse width modulation control10.1177/1477153515615934 ↗
32. Stroboscopic effect: Contrast threshold function and dependence on illumination level10.1364/JOSAA.35.000309 ↗
33. Zhao, X., Hou, D., Lin, Y., and Xu, W. (2018, January 23–25). The Effect of Office Lighting Strobe on Human Physiology. Proceedings of the 2018 15th China International Forum on Solid State Lighting: International Forum on Wide Bandgap Semiconductors China (SSLChina: IFWS), Shenzhen, China.10.1109/IFWS.2018.8587408 ↗
34. 77-1: Invited Paper: Modelling Visibility of Temporal Light Artefacts10.1002/sdtp.12194 ↗
35. Veitch, J.A., and Martinsons, C. (2019). Visual Perception Underenergy-efficient Light Sources: Detection of the Stroboscopic Effect Under Low Levels of SVM, National Research Council Canada.10.25039/x46.2019.PP04 ↗
36. Zhao, X., Li, M., Lin, Y., and Xu, W. (2019, January 25–27). Study of the Stroboscopic Effect Visibility Measure (SVM) based on Cognitive Performance. Proceedings of the 2019 16th China International Forum on Solid State Lighting & 2019 International Forum on Wide Bandgap Semiconductors China (SSLChina: IFWS), Shenzhen, China.10.1109/SSLChinaIFWS49075.2019.9019756 ↗
37. Detection of the stroboscopic effect by young adults varying in sensitivity10.1177/1477153519898718 ↗
38. Effects of long-term exposure to stroboscopic effect from moderate-level modulated light10.1177/1477153519881473 ↗
39. Apryandi, H., Dupuis, P., Sinisuka, N.I., and Zissis, G. (2020, January 10–16). Stroboscopic Visibility Measure: Assessment of pulsed light parameters. Proceedings of the 2020 IEEE Industry Applications Society Annual Meeting, Detroit, MI, USA.10.1109/IAS44978.2020.9334755 ↗
40. The effect of stroboscopic effect on human health indicators10.1177/1477153519871688 ↗
41. Phantom array and stroboscopic effect visibility under combinations of TLM parameters10.1177/14771535231169904 ↗
42. Temporal light modulation: Data processing and metric calculations10.1177/14771535231172085 ↗
43. Effects of temporal light modulation on cognitive performance, eye movements, and brain function10.1080/15502724.2023.2170883 ↗
44. Effects of temporal light modulation on visual task performance in different modulation frequencies10.1177/14771535241278366 ↗
45. The Impact of Temporal Light Modulation on Psychological Responses Assessed by the Stroboscopic Visibility Measure10.1080/15502724.2024.2365686 ↗
46. The phantom array: A perisaccadic illusion of visual direction10.1007/BF03395256 ↗
47. Vogels, I., and Hernando, I. (2012). Effect of eye movements on perception of temporally modulated light. Proc. Exp. Light., 12–13.
48. Flicker can be perceived during saccades at frequencies in excess of 1 kHz10.1177/1477153512436367 ↗
49. P-141: Phantom Array Effect of LED Lighting10.1002/sdtp.12037 ↗
50. Lee, C.-S., Hwang, J., and Lee, D.-H. (2019). Chromatic Dependence of the Contrast Sensitivity Function of the Phantom Array Effect, CIE.10.25039/x46.2019.PO021 ↗
51. Wang, L., Tu, Y., Cheng, S., Yu, X., Perz, M., and Sekulovski, D. (2019, January 14–22). The Visibility of the Phantom Array Effect Under Office Lighting Condition. Proceedings of the CIE, Washington, DC, USA.
52. Research note: Visibility of temporal light artefact from flicker at 11 kHz10.1177/1477153519852391 ↗
53. Visibility of the phantom array effect according to luminance, chromaticity and geometry10.1177/1477153519867115 ↗
54. 2.1: Invited Paper: Dependence of Illumination Level on Phantom Array Effect10.1002/sdtp.14352 ↗
55. Visibility of the phantom array effect at different LED colour temperatures under high-frequency temporal light modulation10.1177/14771535221101558 ↗
56. Martinsons, C., Heynderickx, I., Tengelin, M., Kong, X., and Vogels, R. (2023, January 15–23). Dependence of temporal frequency and chromaticity on the visibility of the phantom array effect. Proceedings of the 30th Quadrennial Session of the CIE International Commission on Illumination. International Commission on Illumination, Ljubljana, Slovenia.
57. Saccadic eye movement speed is related to variations in phantom array effect visibility10.1038/s41598-023-38477-z ↗
58. Phantom array effect can be observed above 15 kHz in high speed eye movement group for high luminance warm white LED10.1177/14771535221147312 ↗
59. Visibility and annoyance of the phantom array effect varies with age and history of migraine10.1177/14771535241288783 ↗
60. Temporal light modulation: A phantom array visibility measure10.1177/14771535241239611 ↗
61. CIE (2022). Visual Aspects of Time-Modulated Lighting Systems. CIE Technical Report 249:2022, CIE—International Commission on Illumination, CIE.
62. Predicting the stroboscopic effects of measured and artificial flicker waveforms through simulation10.1177/1477153514561283 ↗
63. Kobav, M.B., and Colarič, M. (2018, January 20–22). Flicker experimental set up and visual perception of flicker. Proceedings of the 2018 Seventh Balkan Conference on Lighting (BalkanLight), Varna, Bulgaria.10.1109/BalkanLight.2018.8546993 ↗
64. Gaines, J.M. (2026, June 03). Concerns in the Age of the LED: Temporal Light Artifacts. Illuminating Engineering Society. Available online: https://ies.org/fires/concerns-in-the-age-of-the-led-temporal-light-artifacts/.
65. Dimming techniques of visible light communications for human-centric illumination networks: State-of-the-art, challenges, and trends10.1109/MWC.001.1900388 ↗
66. Active optics: A new technology for the control of light10.1109/PROC.1978.10992 ↗
67. Diffractive optics based automotive lighting system: A rear end lamp design for communication between road users10.1515/aot-2020-0055 ↗
68. Photopic, mesopic and scotopic vision and changes in visual performance10.1016/B978-0-12-374203-2.00233-5 ↗
69. Visual discomfort from flicker: Effects of mean light level and contrast10.1016/j.visres.2020.05.002 ↗
70. Perz, M. (2010). Flicker Perception in the Periphery, TU Eindhoven.
71. Adaptation to peripheral flicker10.1016/0042-6989(96)00016-8 ↗
72. European Commission (2019). Laying Down Ecodesign Requirements for Light Sources and Separate Control Gears Pursuant to Directive 2009/125/EC of the European Parliament and of the Council and Repealing Commission Regulations (EC) No 244/2009, (EC) No 245/2009 and (EU) No 1194/2012, Official Journal of the European Union.
73. Erwin, P. (2026, May 01). Der Kompaktflimmergrad CFD. Available online: https://www.derlichtpeter.de.
74. Critical flicker fusion in patients with epilepsy under antiseizure medication10.1002/epd2.20193 ↗
75. Wind turbines, flicker, and photosensitive epilepsy: Characterizing the flashing that may precipitate seizures and optimizing guidelines to prevent them10.1111/j.1528-1167.2008.01563.x ↗
76. Visually sensitive seizures: An updated review by the Epilepsy Foundation10.1111/epi.17175 ↗
77. Specific deficits of flicker sensitivity in glaucoma and ocular hypertension
78. Table-tennis under high intensity discharge (HID) lighting10.1080/00994480.1988.10748705 ↗