journal article·2026-05-01Open access

Evaluation of Mechanical Properties of Zirconia-Based Composites Designed for Biomedical Applications

Agnieszka Wojteczko, Sebastian Komarek, Magdalena Ziąbka

Applied Sciences· Volume 16· Issue 9

Abstract

In this study, bioceramic composites based on zirconia (ZrO2) were synthesized and characterized in terms of mechanical properties. Two types of different-sized grains of zirconia powders were used to prepare the composites. A commercial zirconia micropowder (Tosoh) was used as a base for the composites modified with bioactive glass (BG), copper-doped bioactive glass (BGCu), and hexagonal boron nitride (hBN) with a sintering temperature of 1450 °C. The composites with the addition of hydroxyapatite, for which their sintering temperature was 1150 °C, were independently fabricated using a zirconia nanopowder prepared via co-precipitation and hydrothermal methods to achieve high densification and avoid hydroxyapatite decomposition. Mechanical performance of these composites was assessed with regard to biaxial flexural strength, Vickers hardness (HV), and fracture toughness (KIc). The reference 3Y-TZP material exhibited Vickers hardness (11.8 GPa) and fracture toughness (6.1 MPa∙m1/2 values typical for dense tetragonal zirconia ceramics. The addition of all bioactive phases resulted in significant alterations in mechanical properties. Specifically, incorporating 20 wt.% HAp led to a threefold decrease in hardness and a 40% reduction in fracture toughness, while increasing the HAp content to 40 wt.% further reduced these properties. Nonetheless, the fracture toughness of these composites remained higher than that of pure hydroxyapatite materials. The incorporation of BG and BGCu reduced the hardness values by 45% and 30%, respectively, compared to 3Y-TZP. The most significant deterioration of the properties was observed for the 3Y-TZP-hBN composite. The 3Y-TZP–BGCu composite exhibited fracture toughness (5.9 MPa∙m1/2) representing 95% of the toughness of pure zirconium dioxide, thereby showing the lowest weakness of all the other composites with bioactive additives. A slightly lower fracture toughness value (5.3 MPa∙m1/2) was also observed in the composite with bioglass but lacking the copper additive. This factor, combined with a relatively small decrease in hardness in both cases, highlights high durability for implantology applications, thus marking the indicated materials the most promising among the composites studied.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Advanced ceramic materials synthesis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Ceramics and Refractories, Faculty of Materials Science and Ceramics, AGH—University of Krakow, al. A. Mickiewicza 30, 30-059 Krakow, Poland

Funding

AGH University of Krakow

References (35)

Show source-provided references
1. Zirconia as a ceramic biomaterial10.1016/S0142-9612(98)00010-6 ↗
2. What future for zirconia as a biomaterial?10.1016/j.biomaterials.2005.07.034 ↗
3. Vaiani, L., Boccaccio, A., Uva, A.E., Palumbo, G., Piccininni, A., Guglielmi, P., Cantore, S., Santacroce, L., Charitos, I.A., and Ballini, A. (2023). Ceramic Materials for Biomedical Applications: An Overview on Properties and Fabrication Processes. J. Funct. Biomater., 14.10.3390/jfb14030146 ↗
5. Bioceramics: Past, present and for the future10.1016/j.jeurceramsoc.2007.12.001 ↗
6. Bioceramics: From Concept to Clinic10.1111/j.1151-2916.1991.tb07132.x ↗
7. Mechanical properties of alumina/zirconia composites10.1016/j.ceramint.2019.09.068 ↗
8. Shah, S.P. (1991). Crack Bridging Processes in Toughened Ceramics. Toughening Mechanisms in Quasi-Brittle Materials, Springer.10.1007/978-94-011-3388-3 ↗
9. Transformation Toughening in Zirconia-Containing Ceramics10.1111/j.1151-2916.2000.tb01221.x ↗
10. Investigations of the subcriticalcrack growth phenomenon and the estimation of lifetime of alumina and alumina–zirconia composites with different phase arrangements10.1016/j.ceramint.2016.02.178 ↗
11. Ceramic steel?10.1038/258703a0 ↗
12. The Tetragonal-Monoclinic Transformation in Zirconia: Lessons Learned and Future Trends10.1111/j.1551-2916.2009.03278.x ↗
13. Third-generation biomedical materials10.1126/science.1067404 ↗
14. Hydroxyapatite and tricalcium phosphate composites with bioactive glass as second phase: State of the art and current applications10.1002/jbm.a.35619 ↗
15. Biological evaluation of ZrO2 composites modified with different ceramics additives10.1080/21691401.2024.2422870 ↗
16. Antimicrobial properties and bioactivity of zirconia-based biocomposites10.1080/21691401.2025.2540647 ↗
17. The combined effect of hydroxyapatite and zirconia coatings on magnesium-based-implant to improve corrosion resistance and induce antibacterial activity10.1016/j.jallcom.2023.172790 ↗
18. In vitro and in vivo study of copper-doped bioactive glass for bone regeneration application10.1016/j.matchemphys.2023.128789 ↗
19. Raval, A.S., Yadav, N., Narwani, S., Somkuwar, K., Verma, V., Almubarak, H., Alqahtani, S.M., Tasleem, R., Luke, A.M., and Kuriadom, S.T. (2023). Antibacterial Efficacy and Surface Characteristics of Boron Nitride Coated Dental Implant: An In-Vitro Study. J. Funct. Biomater., 14.10.3390/jfb14040201 ↗
20. Bioceramics of calcium orthophosphates10.1016/j.biomaterials.2009.11.050 ↗
21. Physics of bone bonding mechanism of different surface bioactive ceramic materials in vitro and in vivo
22. Preparation of laminated hydroxyapatite/zirconia sintered composite with the gradient composition10.1023/A:1026487222287 ↗
23. Nano-Hydroxyapatite Composite Biomaterials for Bone Tissue Engineering-A Review10.1166/jbn.2014.1893 ↗
24. Kargozar, S., Hooshmand, S., Hosseini, S.A., Gorgani, S., Kermani, F., and Baino, F. (2022). Antioxidant Effects of Bioactive Glasses (BGs) and Their Significance in Tissue Engineering Strategies. Molecules, 27.10.3390/molecules27196642 ↗
25. Nanotoxicity of boron nitride nanosheet to bacterial membranes10.1021/acs.langmuir.9b00025 ↗
26. Low-temperature degradation of zirconia and implications for biomedical implants10.1146/annurev.matsci.37.052506.084250 ↗
27. Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography10.1016/j.dental.2007.08.001 ↗
28. Strength stability over loading time of zirconia-hydroxyapatite composites10.1016/j.mtcomm.2023.106963 ↗
29. A fracture mechanics analysis of indentation-induced Palmqvist crack in ceramics10.1007/BF00725625 ↗
30. (1996). Test Method for Biaxial Flexure Strength (Modulus of Rupture) of Ceramic Substrates (Standard No. ASTM F394-78).
31. Physico-mechanical and morphological features of zirconia substituted hydroxyapatite nano crystals10.1038/srep43202 ↗
32. A Comparative Study between Melt-Derived and Sol-Gel Synthesized 45S5 Bioactive Glasses10.4028/www.scientific.net/KEM.541.15 ↗
33. Fiume, E., Migneco, C., Verné, E., and Baino, F. (2020). Comparison between Bioactive Sol-Gel and Melt-Derived Glasses/Glass-Ceramics Based on the Multicomponent SiO2–P2O5–CaO–MgO–Na2O–K2O System. Materials, 13.10.3390/ma13030540 ↗
34. Consolidation of nanocrystalline hydroxyapatite powder10.1016/j.stam.2006.11.002 ↗
35. Hydroxyapatite of natural origin—Zirconia composites, preparation and reactions within the system10.2298/PAC1604219B ↗