journal article·2026-05-01Open access

Performance Comparison of Smartphone-Based Portable Slit Lamp Microscopes: A Narrative Review of Medical Devices Applicable to Telemedicine in Ophthalmology

Eisuke Shimizu, Ryota Yokoiwa, Shintaro Nakayama

Applied Sciences· Volume 16· Issue 9

Abstract

Smartphone-based portable slit lamp microscopes are increasingly used as low-cost tools for anterior segment imaging in teleophthalmology, yet the literature combines heterogeneous study designs, comparator standards, and deployment contexts. Because the evidence base spans engineering reports, basic science, clinical validation studies, implementation research, and case-based telemedicine, we structured a narrative review rather than a pooled meta-analysis. We searched PubMed/MEDLINE, Embase, Scopus, Web of Science, Google Scholar, Cochrane Library, ScienceDirect, and DOAJ for literature available on or before 28 February 2026, supplemented by manual reference list screening and targeted retrieval of relevant technical standards. Peer-reviewed English original studies formed the core evidence base; contextual non-English and gray literature sources were retained only when explicitly labeled as non-core. To improve interpretability, the results were grouped by synthesis domain, clinical task, comparator standard, telemedicine scenario, and artificial intelligence (AI) dataset/validation characteristics. The highest-confidence evidence concerned nuclear cataract grading, tear film breakup time and corneal staining assessment, anterior chamber depth screening, tear meniscus height measurement, allergic conjunctival grading, and selected corneal disorders. Agreement with conventional slit lamp examination or anterior segment optical coherence tomography was generally moderate to high within task-specific comparisons, and telemedicine deployment was feasible for screening, follow-up, remote consultation, emergency triage, house visits, and outreach. However, illumination reporting remains inconsistent, explicit ISO-aligned dosimetry is sparse, and most AI studies remain retrospective, single-center, and device family-specific. Current evidence, therefore, supports smartphone-based portable slit lamp microscopes primarily as adjunctive teleophthalmology tools rather than replacements for comprehensive in-clinic microscopy. The synthesis clarifies where conclusions are supported by comparative validation data, where they remain exploratory, and which methodological gaps should be prioritized in future multicenter studies.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ocular Surface and Contact Lens · Ophthalmology and Visual Impairment Studies · Corneal surgery and disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

OUI Inc., Tokyo 107-0062, Japan

Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan

Yokohama Keiai Eye Clinic, Kanagawa 240-0065, Japan

References (100+)

Show source-provided references
1. GBD 2019 Blindness and Vision Impairment Collaborators, and Vision Loss Expert Group of the Global Burden of Disease Study (2021). Causes of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: The Right to Sight: An analysis for the Global Burden of Disease Study. Lancet Glob. Health, 9, e144–e160.
2. Prevalence and causes of vision loss in South-east Asia and Oceania in 2015: Magnitude, temporal trends and projections10.1136/bjophthalmol-2018-311946 ↗
3. Cataract and its surgery in Timor-Leste10.1111/j.1442-9071.2006.01345.x ↗
4. Prevalence and causes of blindness, visual impairment, and cataract surgery in Timor-Leste10.2147/OPTH.S146901 ↗
5. Cheng, J.W., Zong, Y., Zeng, Y.Y., and Wei, R.L. (2014). The prevalence of primary angle closure glaucoma in adult Asians: A systematic review and meta-analysis. PLoS ONE, 9.10.1371/journal.pone.0103222 ↗
6. Prevalence ratio of primary angle-closure and primary open-angle glaucoma in Asian population: A meta-analysis and multiple meta-regression analysis10.3341/kjo.2023.0057 ↗
7. Anterior segment imaging devices in ophthalmic telemedicine10.1080/08820538.2021.1887899 ↗
8. Telemedicine for cornea and external disease: A scoping review of imaging devices10.1007/s40123-023-00764-3 ↗
9. A review of smartphone adapters capable of imaging the anterior segment in ophthalmology10.1080/08820538.2023.2211160 ↗
10. Design and performance characterization of a novel, smartphone-based, portable digital slit lamp for anterior segment screening using telemedicine10.1167/tvst.10.8.29 ↗
11. Novel telemedicine device for diagnosis of corneal abrasions and ulcers in resource-poor settings10.1001/jamaophthalmol.2014.335 ↗
12. Smartphone assisted slit lamp free anterior segment imaging: A novel technique in teleophthalmology10.1016/j.clae.2015.09.005 ↗
13. Teleophthalmic approach for detection of corneal diseases: Accuracy and reliability10.1097/ICO.0000000000001294 ↗
14. App-based teleophthalmology: A novel method of rural eye care delivery connecting tertiary eye care center and vision centers in India
15. Use of a tablet attachment in teleophthalmology for real-time video transmission from rural vision centers in a three-tier eye care network in India: EyeSmart Cyclops
16. Role of teleophthalmology to manage anterior segment conditions in vision centres of south India: EyeSmart study-I10.4103/ijo.IJO_991_19 ↗
17. Smartphone-based anterior segment imaging: A comparative diagnostic accuracy study of a potential tool for blindness prevalence surveys10.1080/09286586.2021.1980589 ↗
18. Portable anterior eye segment imaging system for teleophthalmology10.1167/tvst.12.1.11 ↗
19. (2017). Ophthalmic Instruments-Slit-Lamp Microscopes (Standard No. ISO 10939:2007).
20. (2024). Ophthalmic Instruments-Fundamental Requirements and Test Methods-Part 2: Light Hazard Protection (Standard No. ISO 15004-2:2024).
21. Lee, H.S., Cui, L., Li, Y., Choi, J.S., Choi, J.-H., Li, Z., Kim, G.E., Choi, W., and Yoon, K.C. (2016). Influence of light emitting diode-derived blue light overexposure on mouse ocular surface. PLoS ONE, 11.10.1371/journal.pone.0167671 ↗
22. Effect of smartphone light fluxes on cornea: A biophysical study10.4103/jmp.JMP_89_19 ↗
23. Comparison of ophthalmic toxicity of light-emitting diode and organic light-emitting diode light sources10.1038/s41598-020-68565-3 ↗
24. A safety test for ocular phototoxicity in the rabbit after short-term exposure to strong light10.21873/invivo.12696 ↗
25. Influence of light-emitting diode-derived blue light overexposure on rat ocular surface10.1155/2023/1097704 ↗
26. Shimizu, E., Ogawa, Y., Yazu, H., Aketa, N., Yang, F., Yamane, M., Sato, Y., Kawakami, Y., and Tsubota, K. (2019). Smart Eye Camera: An innovative technique to evaluate tear film breakup time in a murine dry eye disease model. PLoS ONE, 14.10.1371/journal.pone.0215130 ↗
27. Retinal phototoxicity: A review of standard methodology for evaluating retinal optical radiation hazards10.1097/HP.0b013e3181f4993d ↗
28. How safe is the light during ophthalmic diagnosis and surgery10.1038/eye.2015.247 ↗
29. Retinal light exposure from ophthalmoscopes, slit lamps, and overhead surgical lamps. An analysis of potential hazards
30. Blue light exposure: Ocular hazards and prevention-a narrative review10.1007/s40123-023-00675-3 ↗
31. Smart Eye Camera: A validation study for evaluating the tear film breakup time in human subjects10.1167/tvst.10.4.28 ↗
32. Interobserver reliability of tear break-up time examination using Smart Eye Camera in Indonesian remote area10.2147/OPTH.S412233 ↗
33. Borselli, M., Toro, M.D., Rossi, C., Taloni, A., Khemlani, R., Nakayama, S., Nishimura, H., Shimizu, E., Scorcia, V., and Giannaccare, G. (2024). Feasibility of tear meniscus height measurements obtained with a smartphone-attachable portable device and agreement of the results with standard slit lamp examination. Diagnostics, 14.10.3390/diagnostics14030316 ↗
34. Mizukami, T., Sato, S., Asai, K., Inoue, T., Shimizu, E., Shimazaki, J., and Shimomura, Y. (2024). Evaluating the effect of image enhancement on diagnostic reliability in dry eye disease using a portable imaging device. Diagnostics, 14.10.20944/preprints202410.0565.v1 ↗
35. Yazu, H., Shimizu, E., Okuyama, S., Katahira, T., Aketa, N., Yokoiwa, R., Sato, Y., Ogawa, Y., and Fujishima, H. (2020). Evaluation of nuclear cataract with smartphone-attachable slit-lamp device. Diagnostics, 10.10.3390/diagnostics10080576 ↗
36. Diagnostic assessment of nuclear cataracts using a smartphone-attachable slit-lamp device: A cross-sectional study in Vietnam
37. Reliability and accuracy of Smart Eye Camera in determining grading of nuclear cataract10.3341/kjo.2023.0131 ↗
38. Shimizu, E., Yazu, H., Aketa, N., Yokoiwa, R., Sato, S., Yajima, J., Katayama, T., Sato, R., Tanji, M., and Sato, Y. (2021). A study validating the estimation of anterior chamber depth and iridocorneal angle with portable and non-portable slit-lamp microscopy. Sensors, 21.10.3390/s21041436 ↗
39. Sato, M., Shimizu, E., Matsukawa, A., Mizuno, R., Kamido, S., Mizukami, T., Ueda, N., Fujimoto, Y., Tei, N., and Miyake, O. (2026). Prospective evaluation of ocular anterior segment morphology changes in the steep Trendelenburg position during robotic-assisted laparoscopic prostatectomy. J. Clin. Med., 15.10.3390/jcm15020731 ↗
40. Yazu, H., Shimizu, E., Sato, S., Aketa, N., Katayama, T., Yokoiwa, R., Sato, Y., Fukagawa, K., Ogawa, Y., and Tsubota, K. (2021). Clinical observation of allergic conjunctival diseases with portable and recordable slit-lamp device. Diagnostics, 11.10.3390/diagnostics11030535 ↗
41. A study establishing sensitivity and accuracy of smartphone photography in ophthalmologic community outreach programs: Review of a Smart Eye Camera10.4103/IJO.IJO_292_23 ↗
42. Clinical evaluation of corneal ulcer with a portable and smartphone-attachable slit lamp device: Smart Eye Camera10.1038/s41598-025-87820-z ↗
43. Yukari, Y., Senoo, Y., Hayashi, T., Shimizu, T., Hara, Y., Nishimura, H., Nakayama, S., Shimizu, E., and Yamagami, S. (2025). Evaluation of post-keratoplasty status with a portable and smartphone-attachable Smart Eye Camera. PLoS ONE, 20.10.1371/journal.pone.0335450 ↗
44. Validation and optimization of Smart Eye Camera as teleophthalmology device for the reduction of preventable and treatable blindness in Nigeria10.1038/s41433-024-03489-0 ↗
45. Evaluating the diagnostic accuracy of a portable, motorized, and remotely controlled slit lamp imaging adaptor prototype for head-mounted displays10.1167/tvst.13.7.6 ↗
46. A novel smartphone ophthalmic imaging adapter: User feasibility studies in Hyderabad, India10.4103/0301-4738.181742 ↗
47. Training time and quality of smartphone-based anterior segment screening in rural India10.2147/OPTH.S134656 ↗
48. Smartphone imaging in ophthalmology: A comparison with traditional methods on the reproducibility and usability for anterior segment imaging10.47102/annals-acadmedsg.V45N1p6 ↗
49. Tele-manufactured affordable smartphone anterior segment microscope10.1111/cxo.12381 ↗
50. Impact of implementing teleophthalmology referral guidelines using the eyeSmart EMR app in 63,703 patients from India
51. Telemedical diagnosis of anterior segment eye diseases: Validation of digital slit-lamp still images10.1038/eye.2008.11 ↗
52. Global teleophthalmology with iPhones for real-time slitlamp eye examination10.1097/ICL.0000000000000051 ↗
53. Using a macro lens for anterior segment imaging in rural Panama10.1089/tmj.2019.0152 ↗
54. A smartphone lens attachment improves the quality of referrals to eye casualty10.1038/s41433-022-02233-w ↗
55. Evaluation of digital slit-lamp videos for paediatric anterior segment telemedicine consultations10.1177/1357633X21990991 ↗
56. Telemedicine for screening eye disease in the remote Peruvian Amazon: Proof-of-concept10.1093/trstmh/trab175 ↗
57. A case of traumatic hyphema diagnosed by telemedicine between a remote island and the mainland of Tokyo
58. Primary angle closure observed during a house visit: A case treated with laser iridotomy
59. Shimizu, E., Hisajima, K., Nakayama, S., Nishimura, H., Khemlani, R.J., Yokoiwa, R., Shimizu, Y., Kishimoto, M., and Yasukawa, K. (2024). Epidemiological survey of anterior segment diseases in Japanese isolated island using a portable slit-lamp device in home-based cases in Miyako Island. PLoS ONE, 19.10.1371/journal.pone.0306845 ↗
60. Prevalence of anterior segment diseases on a remote island: A telemedicine-based study using the Smart Eye Camera
61. Telemedicine-based diagnosis and management of ocular chemical injury in a remote setting: A case report10.1002/jgf2.70017 ↗
62. The importance of high-quality cataract surgery: A case of objective improvement in post-surgery outcomes at a rural hospital in Vietnam
63. Andrade do Espirito Santos, V., Borges, L.J.C.D.A., Pinto, V.C., Nakayama, S., and Shimizu, E. (2025). Prevalence of Anterior Segment Diseases on Timor-Leste: A Telemedicine-Based Study Using the Smart Eye Camera, Instituto Nacional de Ciencia e Tecnologia.
64. Hieu qua cua thiet bi Smart Eye Camera trong kham ban phan truoc so voi sinh hien vi tren benh nhan tai Benh Vien Dong Do nam 2022–2023
65. Artificial intelligence to estimate the tear film breakup time and diagnose dry eye disease10.1038/s41598-023-33021-5 ↗
66. AI-based diagnosis of nuclear cataract from slit-lamp videos10.1038/s41598-023-49563-7 ↗
67. Yoshitsugu, K., Shimizu, E., Nishimura, H., Khemlani, R., Nakayama, S., and Takemura, T. (2024). Development of the AI pipeline for corneal opacity detection. Bioengineering, 11.10.20944/preprints202402.1156.v1 ↗
68. Shimizu, E., Tanaka, K., Nishimura, H., Agata, N., Tanji, M., Nakayama, S., Khemlani, R.J., Yokoiwa, R., Sato, S., and Shiba, D. (2024). The use of artificial intelligence for estimating anterior chamber depth from slit-lamp images developed using anterior-segment optical coherence tomography. Bioengineering, 11.10.3390/bioengineering11101005 ↗
69. Validation of an artificial intelligence-based anterior chamber depth estimation using a smartphone-compatible slit lamp device10.1016/j.xops.2025.100906 ↗
70. Development of an artificial intelligence algorithm to estimate tear meniscus height using anterior segment optical coherence tomography and a smartphone-based slit-lamp microscope10.1016/j.jfop.2025.100185 ↗
71. Qian, C., Jiang, Y., Da Soh, Z., Selvam, G.S., Xiao, S., Tham, Y.-C., Xu, X., Liu, Y., Li, J., and Zhong, H. (2022). Smartphone-acquired anterior segment images for deep learning prediction of anterior chamber depth: A proof-of-concept study. Front. Med., 9.10.3389/fmed.2022.912214 ↗
72. Development of a novel deep learning-based gaze estimation method for detecting strabismus
73. Artificial intelligence for anterior segment diseases: A review of potential developments and clinical applications10.1007/s40123-023-00690-4 ↗
74. Deep learning for identifying corneal diseases from ocular surface slit-lamp photographs10.1038/s41598-020-75027-3 ↗
75. Hung, N., Shih, A.K.-Y., Lin, C., Kuo, M.-T., Hwang, Y.-S., Wu, W.-C., Kuo, C.-F., Kang, E.Y.-C., and Hsiao, C.-H. (2021). Using slit-lamp images for deep learning-based identification of bacterial and fungal keratitis: Model development and validation with different convolutional neural networks. Diagnostics, 11.10.3390/diagnostics11071246 ↗
76. Determination of probability of causative pathogen in infectious keratitis using deep learning algorithm of slit-lamp images10.1038/s41598-021-02138-w ↗
77. Xu, W., Jin, L., Zhu, P.Z., He, K., Yang, W.H., and Wu, M.N. (2021). Implementation and application of an intelligent pterygium diagnosis system based on deep learning. Front. Psychol., 12.10.3389/fpsyg.2021.759229 ↗
78. Deep learning algorithms for automatic detection of pterygium using anterior segment photographs from slit-lamp and hand-held cameras10.1136/bjophthalmol-2021-318866 ↗
79. Deep learning-based classification of infectious keratitis on slit-lamp images10.1177/20406223221136071 ↗
80. Deep learning-based cataract detection and grading using slit-lamp and retroillumination photographs10.1016/j.xops.2022.100147 ↗
81. A deep learning model established for evaluating lid margin signs with colour anterior segment photography10.1038/s41433-022-02088-1 ↗
82. Wei, S., Wang, Y., Shi, F., Sun, S., and Li, X. (2023). Developing a deep learning model to evaluate bulbar conjunctival injection with color anterior segment photographs. J. Clin. Med., 12.10.3390/jcm12020715 ↗
83. Gan, F., Chen, W.Y., Liu, H., and Zhong, Y.L. (2022). Application of artificial intelligence models for detecting the pterygium that requires surgical treatment based on anterior segment images. Front. Neurosci., 16.10.3389/fnins.2022.1084118 ↗
84. Artificial intelligence support improves diagnosis accuracy in anterior segment eye diseases10.1038/s41598-025-89768-6 ↗
85. A 5-year retrospective study of intraocular pressure control after trabeculectomy: A retrospective cohort study10.1097/MS9.0000000000000621 ↗
86. Successful transition from topical ophthalmic drops to cream formulation in the management of mild allergic conjunctivitis: A case report
87. Use of anterior segment imaging adapter for diagnosing cataract patients: A case series
88. SANRA—A scale for the quality assessment of narrative review articles10.1186/s41073-019-0064-8 ↗
89. Writing narrative literature reviews for peer-reviewed journals: Secrets of the trade10.1016/S0899-3467(07)60142-6 ↗
90. An introduction to writing narrative and systematic reviews—Tasks, tips and traps for aspiring authors10.1016/j.hlc.2018.03.027 ↗
91. A typology of reviews: An analysis of 14 review types and associated methodologies10.1111/j.1471-1842.2009.00848.x ↗
92. Narrative reviews: Flexible, rigorous, and practical10.4300/JGME-D-22-00480.1 ↗
93. PRISMA extension for scoping reviews (PRISMA-ScR): Checklist and explanation10.7326/M18-0850 ↗
94. Reporting scoping reviews-PRISMA ScR extension10.1016/j.jclinepi.2020.03.016 ↗
95. Updated methodological guidance for the conduct of scoping reviews10.11124/JBIES-20-00167 ↗
96. Thomas, J., and Harden, A. (2008). Methods for the thematic synthesis of qualitative research in systematic reviews. BMC Med. Res. Methodol., 8.10.1186/1471-2288-8-45 ↗
97. TFOS DEWS II definition and classification report10.1016/j.jtos.2017.05.008 ↗
98. TFOS DEWS II diagnostic methodology report10.1016/j.jtos.2017.05.001 ↗
99. TFOS DEWS II tear film report10.1016/j.jtos.2017.03.006 ↗
100. TFOS DEWS II report executive summary10.1016/j.jtos.2017.08.003 ↗