Demand-Driven Ozone-Assisted Oxidation in a Recirculating Domestic Kitchen Hood: Experimental Evaluation and RSM Optimization
Source abstract
Abstract
Cooking-related emissions represent a major contributor to indoor air pollution in residential kitchens, producing complex mixtures of volatile organic compounds (VOCs), odor-causing gases, oil vapors, particulate matter (PM2.5), and combustion-related pollutants (CO and NOx). In this study, a controlled ozone-assisted oxidation approach was integrated into a recirculating (ductless) domestic kitchen hood equipped with a confined reaction chamber and experimentally evaluated under closed-loop operating conditions where treated air was returned to the indoor environment after post-treatment. A multivariate Response Surface Methodology (RSM) framework based on the Box–Behnken design was employed to quantify and optimize the coupled effects of temperature (20–30 °C), relative humidity (40–60%), ozone dosage (1–3 ppm within the confined reaction zone), and airflow rate (150–250 m3/h) on multi-pollutant removal performance. The results demonstrate that ozone assistance substantially improves the abatement of oxidation-sensitive pollutants, particularly VOCs and odor, while airflow rate strongly governs transport-dominated pollutants such as PM2.5 and oil vapors. In contrast, CO and NOx exhibited limited improvement, indicating that ozone-assisted oxidation alone is insufficient for comprehensive control of combustion-related gases under short-residence-time recirculating hood conditions. The main contribution of this work is the implementation of a demand-driven ozone management strategy, supported by dual ozone sensing for reaction-zone control and outlet safety verification, where ozone generation is activated only in the presence of reactive gaseous pollutants and automatically reduced or terminated once pollutant concentrations fall below predefined thresholds, minimizing unnecessary oxidant release. Residual ozone downstream of the reaction stage was continuously monitored to prevent excess ozone return to the occupied zone. Overall, the proposed closed-loop, feedback-controlled ozone-assisted recirculating range hood concept demonstrated device-level reductions in measured VOC/odor signals under controlled conditions, while also highlighting the need for complementary post-treatment components for particle- and combustion-related pollutants. However, the potential formation of secondary oxidation byproducts was not characterized in this study, and therefore the results should be interpreted with respect to device-level pollutant removal rather than comprehensive indoor air quality improvement.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Indoor Air Quality and Microbial Exposure · Building Energy and Comfort Optimization · Infection Control and Ventilation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Industrial Engineering, Engineering Faculty, Hitit University, 19030 Corum, Türkiye
Department of Statistics, Science Faculty, Eskisehir Technical University, 26470 Eskisehir, Türkiye
References (25)
Show source-provided references
1. Indoor air quality and its effects on humans—A review of challenges and developments in the last 30 years10.1016/j.enbuild.2016.08.071 ↗
2. Impact of cooking methods on indoor air quality: A comparative study of particulate matter (PM) and volatile organic compound (VOC) emissions10.1155/2024/6355613 ↗
3. Polycyclic aromatic hydrocarbons (PAHs) exposure through cooking environment and assessment strategies for human health implications10.1080/10807039.2022.2081836 ↗
4. Indoor air quality and energy-saving potential improvement of a range-hood-integrated air cleaner10.1080/23744731.2023.2234238 ↗
5. Particle dispersion and removal associated with kitchen range hood and whole house ventilation system10.1016/j.buildenv.2023.109986 ↗
6. Chemical and catalytic properties of ozone10.1081/CR-100100263 ↗
7. Effect of ionizers on indoor air quality and performance of air cleaning systems10.4209/aaqr.230240 ↗
8. The effects of ozone on human health10.1007/s11356-017-9239-3 ↗
9. Indoor ozone: Concentrations and influencing factors10.1111/ina.12942 ↗
10. Montgomery, D.C. (2017). Design and Analysis of Experiments, John Wiley & Sons.
11. A novel swirling-flow range hood for improving the kitchen air quality and energy efficiency10.1016/j.buildenv.2025.113488 ↗
12. Particle emission factors during cooking activities10.1016/j.atmosenv.2009.03.044 ↗
13. Advancements in Hybrid and Combined Biological Technologies for Treating Polluted Gases: A Comprehensive Review10.1007/s11270-025-07779-5 ↗
14. Performance assessment of the range hood with an air supply system in cooking kitchen for improving air quality and thermal comfort10.1016/j.applthermaleng.2025.125572 ↗
15. Effect of ozone, clothing, temperature, and humidity on the total OH reactivity emitted from humans10.1021/acs.est.1c01831 ↗
16. The development and assessment of an aspiration efficiency reducing system of air pollution control for particulate matter in building ventilation systems10.1016/j.enbuild.2013.02.024 ↗
17. Ciattaglia, G., Iadarola, G., Gambi, E., and Spinsante, S. (2024). Design and Power Consumption Analysis of a Smart Hood to Reduce Indoor Air Pollution. Proceedings of the 2024 IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4. 0 & IoT), Florence, Italy, 29–31 May 2024, IEEE.10.1109/MetroInd4.0IoT61288.2024.10584181 ↗
18. Vertical changes in volatile organic compounds (VOCs) and impacts on photochemical ozone formation10.5194/acp-25-2459-2025 ↗
19. Li, S. (2023). Review of engineering controls for indoor air quality: A systems design perspective. Sustainability, 15.10.3390/su151914232 ↗
20. Reaction of ozone with carbon monoxide10.1021/j100655a002 ↗
21. Reaction of carbon monoxide with ozone: Kinetics and mechanism10.1002/kin.550120804 ↗
22. Emissions and exposure to NOx, CO, CO2 and PM2.5 from a gas stove using reference and low-cost sensors10.1016/j.atmosenv.2024.120564 ↗
23. Catalysis removal of indoor volatile organic compounds in room temperature: From photocatalysis to active species assistance catalysis10.1007/s10563-014-9177-8 ↗
24. Ozone loss: A surrogate for the indoor concentration of ozone-derived products10.1021/acs.est.3c03968 ↗
25. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review10.1016/j.atmosenv.2011.05.041 ↗