Reproducibility of 4D Flow MRI-Derived Diastolic Function Testing by Mitral and Pulmonary Venous Flow Indices in Healthy Volunteers
Source abstract
Abstract
Accurate assessment of mitral valve (MV) and pulmonary vein (PV) flow velocities is important for left ventricular diastolic function testing. This study investigated the scan–rescan reproducibility of 4D Flow MRI-assessed MV and PV flow velocities in 21 healthy volunteers (25 ± 4 years). Participants underwent repeated whole-heart 3T 4D Flow MRI involving repositioning and different respiratory compensation strategies (motion-uncompensated free-breathing vs. respiratory motion-compensated navigator gating). MV parameters (net flow volume (NFV), E-wave velocity, A-wave velocity, E/A ratio, E deceleration time (DT), annular e’ velocity, E/e’ ratio) and PV parameters (NFV, S-wave velocity, D-wave velocity, S/D ratio, atrial reversal (AR) wave velocity) were derived from velocity–time curves and compared using intraclass correlation coefficients (ICCs), Bland–Altman analysis, and Pearson’s correlation (r). Results showed significant moderate-to-strong scan–rescan agreement and correlation for most MV and PV parameters (ICC = 0.51–0.92; r = 0.51–0.92; all p < 0.05), except E DT, e’ velocity, E/e’ ratio, PV NFV, and AR velocity (ICC = −0.13–0.47; r = −0.14–0.47). Subanalysis of respiratory motion strategies showed moderate-to-strong agreement and correlation for MV and PV parameters (ICC = 0.61–0.99; r = 0.52–0.99; all p < 0.05 excluding E DT), except E DT (ICC = 0.44) and PV NFV (ICC = 0.46; r = 0.46). While intraobserver agreement was mostly moderate-to-excellent (ICC = 0.58–0.97; ICC = 0.41 for E DT), interobserver agreement was poor for E DT and PV parameters (ICC = −0.12–0.34). Overall, 4D Flow MRI shows acceptable reproducibility for selected diastolic flow parameters, particularly mitral inflow indices, but substantial variability and limited robustness for key indices currently restrict its clinical applicability.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cardiovascular Function and Risk Factors · Advanced MRI Techniques and Applications · Cardiac Imaging and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Radiology, Catharina Hospital Eindhoven, 5623 EJ Eindhoven, The Netherlands
Department of Radiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
Department of Cardiology, Catharina Hospital Eindhoven, 5623 EJ Eindhoven, The Netherlands
Funding
Dutch Society for Radiology
References (28)
Show source-provided references
1. Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging10.1016/j.echo.2016.01.011 ↗
2. Left Ventricular Diastolic Function: Understanding Pathophysiology, Diagnosis, and Prognosis with Echocardiography10.1016/j.jcmg.2018.10.038 ↗
3. The Assessment of Left Ventricular Diastolic Function: Guidance and Recommendations from the British Society of Echocardiography10.1186/s44156-024-00051-2 ↗
4. Pulmonary Venous Flow by Doppler Echocardiography: Revisited 12 Years Later10.1016/S0735-1097(03)00126-8 ↗
5. Added Value of Pulmonary Venous Flow Doppler Assessment in Patients with Preserved Ejection Fraction and Its Contribution to the Diastolic Grading Paradigm10.1093/ehjci/jev126 ↗
6. How to Image Individual Pulmonary Veins with Transthoracic Echocardiography
7. Dong, Q.-Q., Yang, W.-Y., Sun, Y.-P., Zhang, Q., Chu, G., Zhou, G.-Q., Chen, G., Chen, S.-W., Liu, S.-W., and Wang, F. (2019). Comparison of Transthoracic Echocardiography with Computed Tomography in Evaluation of Pulmonary Veins. BMC Cardiovasc. Disord., 19.10.1186/s12872-019-01272-8 ↗
8. Feasibility, Repeatability, and Reproducibility of Contemporary Diastolic Parameters and Classification10.1007/s10554-020-02069-z ↗
9. 4D Flow Cardiovascular Magnetic Resonance Consensus Statement: 2023 Update10.1186/s12968-023-00942-z ↗
10. Multicenter Consistency Assessment of Valvular Flow Quantification with Automated Valve Tracking in 4D Flow CMR10.1016/j.jcmg.2020.12.014 ↗
11. Normal Pulmonary Venous Flow Characteristics as Assessed by Transesophageal Pulsed Doppler Echocardiography10.1016/S0894-7317(14)80324-6 ↗
12. Effects of Respiration on Pulmonary Venous Flow and Its Clinical Applications by Doppler Echocardiography10.1111/j.1540-8175.2008.00792.x ↗
13. Scan-Rescan Reproducibility of Diastolic Left Ventricular Kinetic Energy, Viscous Energy Loss and Vorticity Assessment Using 4D Flow MRI: Analysis in Healthy Subjects10.1007/s10554-017-1291-z ↗
14. The Effect of Respiratory Motion Compensation in Intracardiac 4D Flow Magnetic Resonance Imaging on Left Ventricular Flow Dynamics, Multicomponent Particle Tracing, and Valve Tracking10.1093/ehjimp/qyaf020 ↗
15. 4D Flow MRI-Based Grading of Left Ventricular Diastolic Dysfunction: A Validation Study against Echocardiography10.1007/s00330-025-11703-0 ↗
16. Assadi, H., Li, R., Grafton-Clarke, C., Uthayachandran, B., Alabed, S., Maiter, A., Archer, G., Swoboda, P.P., Sawh, C., and Ryding, A. (2023). Automated 4D Flow Cardiac MRI Pipeline to Derive Peak Mitral Inflow Diastolic Velocities Using Short-Axis Cine Stack: Two Centre Validation Study against Echocardiographic Pulse-Wave Doppler. BMC Cardiovasc. Disord., 23.10.1186/s12872-023-03052-x ↗
17. Diastolic Function Assessment with Four-Dimensional Flow Cardiovascular Magnetic Resonance Using Automatic Deep Learning E/A Ratio Analysis10.1016/j.jocmr.2024.101042 ↗
18. Flow-Sensitive Four-Dimensional Cine Magnetic Resonance Imaging for Offline Blood Flow Quantification in Multiple Vessels: A Validation Study10.1002/jmri.22280 ↗
19. Systemic-to-Pulmonary Collateral Flow in Patients with Palliated Univentricular Heart Physiology: Measurement Using Cardiovascular Magnetic Resonance 4D Velocity Acquisition10.1186/1532-429X-14-25 ↗
20. Improved Quantification and Mapping of Anomalous Pulmonary Venous Flow with Four-Dimensional Phase-Contrast MRI and Interactive Streamline Rendering10.1002/jmri.24928 ↗
21. Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations: Comparison with In Vivo 4D Flow MRI10.1007/s10439-018-02153-5 ↗
22. Prevalence of Venovenous Shunting and High-Output State Quantified with 4D Flow MRI in Patients with Fontan Circulation10.1148/ryct.210161 ↗
23. Quantification of Systemic-to-Pulmonary Collateral Flow in Univentricular Physiology with 4D Flow MRI10.1017/S1047951122002840 ↗
24. Comparison of Respiratory Motion Suppression Techniques for 4D Flow MRI10.1002/mrm.26574 ↗
25. Validation and Reproducibility of Cardiovascular 4D-Flow MRI from Two Vendors Using 2 × 2 Parallel Imaging Acceleration in Pulsatile Flow Phantom and in Vivo with and without Respiratory Gating10.1177/0284185118784981 ↗
26. Kanski, M., Töger, J., Steding-Ehrenborg, K., Xanthis, C., Bloch, K.M., Heiberg, E., Carlsson, M., and Arheden, H. (2015). Whole-Heart Four-Dimensional Flow Can Be Acquired with Preserved Quality without Respiratory Gating, Facilitating Clinical Use: A Head-to-Head Comparison. BMC Med. Imaging, 15.10.1186/s12880-015-0061-4 ↗
27. Reproducibility and Changes in Vena Caval Blood Flow by Using 4D Flow MRI in Pulmonary Emphysema and Chronic Obstructive Pulmonary Disease (COPD): The Multi-Ethnic Study of Atherosclerosis (MESA) COPD Substudy10.1148/radiol.2019182143 ↗
28. Comparison of 2D and 4D Flow MRI Measurements for Hemodynamic Evaluation of the Fontan Palliation10.32604/chd.2023.030312 ↗