journal article·2026-03-05Open access

PSO-Based Ensemble Learning Enhanced with Explainable Artificial Intelligence for Breast Glandular Dose Estimation in Mammography

Sevgi Ünal, Remzi Gürfidan

Applied Sciences· Volume 16· Issue 5

Abstract

Objectives: This study aims to predict patient-specific Average Glandular Dose (AGD) in mammography using machine learning-based models to support personalised radiation dose optimisation and reduce unnecessary exposure during breast cancer screening. Methods: A retrospective dataset of 671 female patients who underwent full-field digital mammography between 2020 and 2024 was analysed. Right craniocaudal (CC) images were used to construct a structured dataset including mAs, kVp, compressed breast thickness, air kerma (k_air), half-value layer (HVL), and breast pattern. Five regression-based machine learning models (CatBoost, Gradient Boosting, Random Forest, Extra Trees, and AdaBoost) and their Particle Swarm Optimisation (PSO)-enhanced versions were evaluated. Model performance was assessed using MSE, RMSE, MAE, MAPE, and R2. SHAP analysis was applied to interpret model predictions and determine variable importance. Results: PSO integration significantly reduced prediction errors, particularly in boosting-based models. The CatBoost + PSO model achieved the best performance (RMSE = 0.0100, MAPE ≈ 1.74%, R2 = 0.9846), followed by the Gradient Boosting + PSO model (R2 = 0.9787). PSO reduced RMSE and MAPE by approximately 55% and 52%, respectively. SHAP analysis identified k_air, breast thickness, and breast pattern as the most influential factors affecting AGD. Conclusions: Machine learning models enhanced with PSO, especially CatBoost + PSO, provide accurate and reliable patient-specific AGD predictions. The proposed approach enables rapid and clinically applicable dose estimation and highlights breast pattern as a critical parameter influencing glandular dose, supporting personalised radiation dose optimisation in mammography.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Digital Radiography and Breast Imaging · AI in cancer detection · Radiation Dose and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Radiology, Izmir Katip Celebi University Ataturk Training and Research Hospital, Izmir 35150, Türkiye

Isparta Vocational School of Information Technologies, Database, Network Design and Management, Isparta University of Applied Science, Isparta 32200, Türkiye

References (34)

Show source-provided references
1. Global patterns and trends in breast cancer incidence and mortality across 185 countries10.1038/s41591-025-03502-3 ↗
2. Advances in breast cancer detection with screening mammography
3. Radiation-Induced Breast Cancer Incidence and Mortality From Digital Mammography Screening: A Modeling Study10.7326/M15-1241 ↗
4. Noor, K.A.M., Norsuddin, N.M., Abdulkerim, M.H., Che İsa, I.N., and Ulaganathan, V. (2024). Evaluating factors affecting mean glandular dose in mammography: Insights from a retrospective study in Dubai. Diagnostics, 14.10.3390/diagnostics14222568 ↗
5. Evaluation of mean glandular dose from mammography screening: A single-center study
6. Evaluation of mean glandular dose in mammography system using different anode-filter combinations with MCNP code10.5812/iranjradiol.36484 ↗
7. Conformance of mean glandular dose from phantom and patient data in mammography10.1093/rpd/ncu261 ↗
8. Dosimetry in x-ray-based breast imaging10.1088/0031-9155/61/19/R271 ↗
9. Comparison of personalized breast dosimetry with standard dosimetry protocols10.1038/s41598-019-42144-7 ↗
10. Teoh, K.C., Abdul Manan, H., Mohd Norsuddin, N., and Rizuana, I.H. (2021). Comparison of mean glandular dose between full-field digital mammography and digital breast tomosynthesis. Healthcare, 9.10.3390/healthcare9121758 ↗
11. Average glandular dose (AGD) and radiation dose optimization in screen-film and digital X-ray mammography10.3390/app132111901 ↗
12. The generalized contrast-to-noise ratio: A formal definition for lesion detectability
13. Improved image quality for dense breasts in mammography10.1259/0007-1285-65-769-50 ↗
14. Update on Breast Density, Risk Estimation, and Supplemental Screening
15. The relationship of the mean glandular dose with compressed breast thickness in mammography10.21037/jphe.2017.03.10 ↗
16. Estimation of mean glandular dose for contrast-enhanced digital mammography: Factors for use with the UK, European and IAEA breast dosimetry protocols10.1088/0031-9155/59/9/2127 ↗
17. Additional factors for the estimation of mean glandular breast dose using the United Kingdom mammography dosimetry protocol10.1088/0031-9155/45/11/308 ↗
18. Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose10.1088/0031-9155/35/9/002 ↗
19. A Monte Carlo model for the evaluation of mean glandular dose in spot compression mammography10.1002/mp.12339 ↗
20. Evaluation of a patient dose monitoring system for the estimation of average glandular dose (AGD) in mammography10.3390/app15063338 ↗
21. Effect of different breast densities and average glandular dose on contrast-to-noise ratios in full-field digital mammography: Simulation and phantom study
22. Phantom-based comparative analysis of contrast-enhanced mammography systems: Image quality and performance evaluation10.1002/acm2.70163 ↗
23. The myth of the 50-50 breast10.1118/1.3250863 ↗
24. Evaluation of average glandular dose in a full-field digital mammography unit in Tabriz, Iran10.1093/rpd/ncq218 ↗
25. Patient dose in digital mammography10.1118/1.1784591 ↗
26. The Study of Mean Glandular Dose in Mammography in Yazd and the Factors Affecting It
27. Homogeneous and patient-specific breast models for Monte Carlo evaluation of mean glandular dose in mammography10.1016/j.ejmp.2018.04.392 ↗
28. Variations in breast doses for an automatic mammography system
29. Dhou, S., Dalah, E., AlGhafeer, R., Hamidu, A., and Obaideen, A. (2022). Regression analysis between the different breast dose metrics and mammography parameters. J. Imaging, 8.10.3390/jimaging8080211 ↗
30. Estimation of glandular dose in mammography based on artificial neural networks10.1088/1361-6560/ab7a6d ↗
31. Comparison of multiple linear regression analysis and artificial neural network approaches in the estimation of Monte Carlo mean glandular dose calculations of mammography
32. Trends in patient dose and compression force for digital (DR) mammography systems over an eleven-year period10.1007/s13246-023-01357-x ↗
33. Spectral dependence of glandular tissue dose in screen-film mammography10.1148/radiology.179.1.2006265 ↗
34. Highnam, R., Brady, S.M., Yaffe, M.J., Karssemeijer, N., and Harvey, J. (2010). Robust breast composition measurement-VolparaTM. International Workshop on Digital Mammography, Springer.10.1007/978-3-642-13666-5_46 ↗