Evaluation of the Precision and Accuracy of Computer-Guided Implant Surgery: A Prospective Clinical Study Comparing .STL Files from the Intraoral Rehabilitation Scanning with the Digital Project
Source abstract
Abstract
Objectives: This prospective cohort study aimed to evaluate the accuracy and precision of static computer-guided, flapless implant surgery in partially edentulous patients, comparing the virtually planned and clinically achieved implant positions. Materials and Methods: From 2017 to 2022, 40 patients (20 males and 20 females) received a total of 129 implants across 59 partial rehabilitations, with 62 implants placed in the maxilla and 67 in the mandible. All interventions were performed by a single experienced operator using dental-supported stereolithographic guides and a flapless protocol. The discrepancy between planned and actual implant positions was measured using reverse engineering software, assessing linear deviations at the implant Platform (coronal) and apex, as well as angular deviations. Subgroup analyses were conducted based on the jaw (maxilla vs. mandible) and the type of surgical guide support (Kennedy classes I–IV). Results: The mean linear deviation was 1.16 ± 0.58 mm at the apex and 0.80 ± 0.41 mm at the implant Platform (coronal). The mean angular deviation was 3.23° ± 1.86°. Slightly higher deviations were observed in the mandible than in the maxilla. Group-wise analysis showed minor variations depending on the type of guide support. Conclusions: Static computer-guided surgery demonstrated measurable linear and angular deviations between planned and achieved implant positions. These discrepancies should be considered during treatment planning, especially in narrow ridges or Class I configurations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Periodontal Regeneration and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Dental Clinic, Unit of Fixed and Implant-Prosthodontics, Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milano, Italy
Department of Clinical Surgical, Diagnostic and Pediatric Sciences, School of Dentistry, University of Pavia, 27100 Pavia, Italy
References (23)
Show source-provided references
1. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis10.1111/clr.13346 ↗
2. Clinical factors affecting the accuracy of guided implant surgery: A systematic review and meta-analysis10.1016/j.jebdp.2017.07.007 ↗
3. Tolerance within a surgical guide10.1111/j.1600-0501.2009.01836.x ↗
4. The intrinsic error of a stereolithographic surgical template in implant guided surgery10.1016/j.ijom.2012.06.010 ↗
5. Tolerance within the sleeve inserts of different surgical guides for guided implant surgery10.1111/j.1600-0501.2012.02436.x ↗
6. Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: A prospective radiological study10.1111/j.1600-0501.2010.02070.x ↗
7. Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review10.1111/clr.13142 ↗
8. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae10.1111/j.1708-8208.2009.00255.x ↗
9. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications10.1016/j.ejrad.2008.06.002 ↗
10. Comparison of radiation doses between cone-beam CT and multi-detector CT: TLD measurements10.1093/rpd/ncn305 ↗
11. Stereolithographic surgical templates for placement of dental implants in complex cases
12. Accuracy and complications of computer-designed selective laser sintering surgical guides for flapless dental implant placement and immediate definitive prosthesis installation10.1902/jop.2011.110115 ↗
13. Computer-guided surgery in implantology: Review of basic concepts10.1097/SCS.0b013e3181f4b1a0 ↗
14. Accuracy of computer-aided oral implant surgery: A clinical and radiographic study
15. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry10.1111/j.1600-0501.2009.01788.x ↗
16. Computer technology applications in surgical implant dentistry: A systematic review
17. On cone-beam computed tomography artifacts induced by titanium implants10.1111/j.1600-0501.2009.01817.x ↗
18. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology10.1016/j.tripleo.2008.03.018 ↗
19. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement10.1016/j.joms.2008.09.033 ↗
20. Accuracy of three different types of stereolithographic surgical guide in implant placement: An in vitro study10.1016/S0022-3913(12)60145-0 ↗
21. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology10.11607/ijp.4835 ↗
22. Inferior alveolar nerve damage related to dental implant placement. A systematic review and meta-analysis
23. Sala, Y.M., Lu, H., and Chrcanovic, B.R. (2024). Clinical Outcomes of Maxillary Sinus Floor Perforation by Dental Implants and Sinus Membrane Perforation during Sinus Augmentation: A Systematic Review and Meta-Analysis. J. Clin. Med., 13.10.3390/jcm13051253 ↗