journal article·2026-02-06Open access

Impact of Non-Linear CT Resampling on Enhancing Synthetic-CT Generation in Total Marrow and Lymphoid Irradiation

Monica Bianchi, Nicola Lambri, Daniele Loiacono, Stefano Tomatis, Marta Scorsetti, Cristina Lenardi, Pietro Mancosu

Applied Sciences· Volume 16· Issue 3

Abstract

Computed tomography (CT) images are stored at a 12-bit depth. However, many deep learning libraries and pre-trained models are designed for 8-bit images, requiring an intermediate compression step before restoring the original 12-bit physical range. This process causes information loss and can compromise image reliability. This study investigated the impact of two CT resampling methods (8-bit compression; 12-bit decompression) on dose calculation and image quality. Ten total marrow and lymphoid irradiation patients were selected. CT scans were resampled using linear and non-linear look-up tables (l_LUT/nl_LUT). Original and resampled CTs were evaluated considering: (i) Hounsfield unit (HU) root mean squared error (RMSE); (ii) dose-volume histogram (DVH) statistics for target volume and several organs; (iii) 3D gamma passing rate (GPR) with a 1%/1.25 mm criterion; (iv) lymph nodes contouring and diagnostic quality (scale 1–5). The RMSE for l_LUT vs. nl_LUT was 7 ± 1 vs. 10 ± 1 HU. Maximum differences in DVH statistics were 0.4%, with a 3D-GPR = 100% for all cases. CTs resampled with l_LUT exhibited evident brain pixelation (score = 1), whereas nl_LUT matched the original CT quality (score = 4). Both LUTs were acceptable for lymph nodes delineation. The nl_LUT optimized the CT resampling process, providing a more efficient method for possible deep learning applications in synthetic CT generation.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Dose and Imaging · Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Milan, Italy

Dipartimento di Fisica “Aldo Pontremoli”, Università degli Studi di Milano, via Giovanni Celoria 16, 20133 Milan, Italy

Scuola di Specializzazione in Fisica Medica, Università degli Studi di Milano, via Giovanni Celoria 16, 20133 Milan, Italy

Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, via Giuseppe Ponzio 34, 20133 Milan, Italy

Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20072 Milan, Italy

INFN, Sezione di Milano, via Giovanni Celoria 16, 20133 Milan, Italy

References (38)

Show source-provided references
1. A Review of Substitute CT Generation for MRI-Only Radiation Therapy10.1186/s13014-016-0747-y ↗
2. Whole-Body MR Imaging of Bone Marrow10.1016/j.ejrad.2005.01.019 ↗
3. New Developments in MRI for Target Volume Delineation in Radiotherapy10.1259/bjr/41321492 ↗
4. SynthRAD2025 Grand Challenge dataset: Generating synthetic CTs for radiotherapy from head to abdomen10.1002/mp.17981 ↗
5. Adaptive Radiation Therapy: A Review of CT-Based Techniques10.1148/rycan.230011 ↗
6. Deep Learning Methods to Generate Synthetic CT from MRI in Radiotherapy: A Literature Review10.1016/j.ejmp.2021.07.027 ↗
7. Deep Learning Based Synthetic-CT Generation in Radiotherapy and PET: A Review10.1002/mp.15150 ↗
8. Vera-Olmos, J., Torrado-Carvajal, A., Prieto-de-la-Lastra, C., Catalano, O.A., Rozenholc, Y., Mazzeo, F., Soricelli, A., Salvatore, M., Izquierdo-Garcia, D., and Malpica, N. (2022). How to Pseudo-CT: A Comparative Review of Deep Convolutional Neural Network Architectures for CT Synthesis. Appl. Sci., 12.10.3390/app122211600 ↗
9. Vellini, L., Zucca, S., Lenkowicz, J., Menna, S., Catucci, F., Quaranta, F., Pilloni, E., D’Aviero, A., Aquilano, M., and Di Dio, C. (2024). A Deep Learning Approach for the Fast Generation of Synthetic Computed Tomography from Low-Dose Cone Beam Computed Tomography Images on a Linear Accelerator Equipped with Artificial Intelligence. Appl. Sci., 14.10.3390/app14114844 ↗
10. Synthetic CT Generation from MRI Using 3D Transformer-Based Denoising Diffusion Model10.1002/mp.16847 ↗
11. Multitask 3D CBCT-to-CT Translation and Organs-at-Risk Segmentation Using Physics-Based Data Augmentation10.1002/mp.15083 ↗
12. Klaser, K., Borges, P., Shaw, R., Ranzini, M., Modat, M., Atkinson, D., Thielemans, K., Hutton, B., Goh, V., and Cook, G. (2021). A Multi-Channel Uncertainty-Aware Multi-Resolution Network for MR to CT Synthesis. Appl. Sci., 11.10.3390/app11041667 ↗
13. Karimzadeh, M., Seyedarabi, H., Jodeiri, A., and Afrouzian, R. (2025). Enhanced Brain Stroke Lesion Segmentation in MRI Using a 2.5D Transformer Backbone U-Net Model. Brain Sci., 15.10.3390/brainsci15080778 ↗
14. Usama, Z., Alavi, A., and Chan, J. (2025). A Review on the Applications of GANs for 3D Medical Image Analysis. Appl. Sci., 15.10.3390/app152011219 ↗
15. Marcel, S., and Rodriguez, Y. (2010, January 25–29). Torchvision the Machine-Vision Package of Torch. Proceedings of the 18th ACM International Conference on Multimedia, Firenze, Italy.10.1145/1873951.1874254 ↗
16. Improving Synthetic CT Accuracy by Combining the Benefits of Multiple Normalized Preprocesses10.1002/acm2.14004 ↗
17. Development of an Immobilization Device for Total Marrow Irradiation10.1016/j.prro.2020.02.012 ↗
18. Improving Radiotherapy Planning in Patients with Metallic Implants Using the Iterative Metal Artifact Reduction (iMAR) Algorithm10.1088/2057-1976/1/2/025206 ↗
19. Dei, D., Lambri, N., Stefanini, S., Vernier, V., Brioso, R.C., Crespi, L., Clerici, E., Bellu, L., De Philippis, C., and Loiacono, D. (2023). Internal Guidelines for Reducing Lymph Node Contour Variability in Total Marrow and Lymph Node Irradiation. Cancers, 15.10.3390/cancers15051536 ↗
20. Anatomy Driven Optimization Strategy for Total Marrow Irradiation with a Volumetric Modulated Arc Therapy Technique10.1120/jacmp.v13i1.3653 ↗
21. Limits of Normality of Quantitative Thoracic CT Analysis10.1186/cc12738 ↗
22. DenOtter, T.D., and Schubert, J. (2025). Hounsfield Unit. StatPearls, StatPearls Publishing.
23. Kim, H., Kim, G., Yoon, B.C., Kim, K., Kim, B.-J., Choi, Y.H., Czosnyka, M., Oh, B.-M., and Kim, D.-J. (2014). Quantitative Analysis of Computed Tomography Images and Early Detection of Cerebral Edema for Pediatric Traumatic Brain Injury Patients: Retrospective Study. BMC Med., 12.10.1186/s12916-014-0186-2 ↗
24. CT Hounsfield Numbers of Soft Tissues on Unenhanced Abdominal CT Scans: Variability Between Two Different Manufacturers’ MDCT Scanners10.2214/AJR.12.10037 ↗
25. PyMedPhys: A Community Effort to Develop an Open, Python-Based Standard Library for Medical Physics Applications10.21105/joss.04555 ↗
26. ICRU Reports (1976). Reports of the International Commission on Radiation Units and Measurements. J. ICRU, os-13, 63–65.10.1093/jicru_os13.1.63 ↗
27. Papanikolaou, N., Battista, J.J., Boyer, A.L., Kappas, C., Klein, E., Mackie, T.R., Sharpe, M., and Dyk, J.V. (2004). Tissue Inhomogeneity Corrections for Megavoltage Photon Beams, AAPM.10.37206/86 ↗
28. Dosimetric Comparison of Analytic Anisotropic Algorithm and Acuros XB Algorithm in VMAT Plans for High-Grade Glioma10.1016/j.ejmp.2020.04.007 ↗
29. Dosimetric Impact of Using the Acuros XB Algorithm for Intensity Modulated Radiation Therapy and RapidArc Planning in Nasopharyngeal Carcinomas10.1016/j.ijrobp.2012.08.031 ↗
30. Dosimetric Comparison of Acuros XB with Collapsed Cone Convolution/Superposition and Anisotropic Analytic Algorithm for Stereotactic Ablative Radiotherapy of Thoracic Spinal Metastases10.1120/jacmp.v16i4.5493 ↗
31. Dosimetric Verification of Four Dose Calculation Algorithms for Spine Stereotactic Body Radiotherapy10.1093/jrr/rrad086 ↗
32. Dosimetric Evaluation of the Acuros XB Algorithm for a 4 MV Photon Beam in Head and Neck Intensity-Modulated Radiation Therapy10.1120/jacmp.v16i4.5222 ↗
33. Comparative Evaluation of Modern Dosimetry Techniques near Low- and High-Density Heterogeneities10.1120/jacmp.v16i5.5589 ↗
34. On the Dosimetric Impact of Inhomogeneity Management in the Acuros XB Algorithm for Breast Treatment10.1186/1748-717X-6-103 ↗
35. Dosimetric Evaluation of Acuros XB Advanced Dose Calculation Algorithm in Heterogeneous Media10.1186/1748-717X-6-82 ↗
36. Considerations for Intensity Modulated Total Body or Total Marrow and Lymphoid Irradiation
37. Determination of Computed Tomography Number of High-Density Materials in 12-Bit, 12-Bit Extended and 16-Bit Depth for Dosimetric Calculation in Treatment Planning System10.1017/S1460396919000013 ↗
38. Effects of 16-Bit CT Imaging Scanning Conditions for Metal Implants on Radiotherapy Dose Distribution