journal article·2026-01-28Open access

Study on Geometric Scattering Effects Correction for Precise Estimation of Fast Neutron Shielding in Polyethylene Materials

Yuxin Lei, Peng Xu, Changbing Lu, Yu Wang, Wangtao Yu

Applied Sciences· Volume 16· Issue 3

Abstract

Fast neutron shielding is a critical component of radiation protection design. Conventional exponential attenuation models based on the narrow-beam (beam approximation) assumption often exhibit large deviations in realistic geometries because they neglect the contribution of scattered neutrons—an effect that becomes particularly prominent for thick hydrogenous shields such as polyethylene. To improve the accuracy of rapid shielding estimates, this study systematically investigates how the “source–shield–detector” geometric configuration influences fast neutron scattering in polyethylene. To overcome the limited adaptability of traditional build-up factor corrections in complex geometries, we propose a physics-informed scattering correction (SC) model. By introducing key geometric parameters—source-to-shield distance, shield thickness, and detector distance—the model dynamically modifies the classical exponential attenuation formulation and analytically integrates the scattered-neutron contribution to the detector flux. Validation against 70 representative geometric configurations simulated with the Monte Carlo code Geant4 shows that the proposed model reduces the mean absolute percentage error (MAPE) from approximately 54% for the exponential attenuation model to approximately 20%, effectively addressing severe flux underestimation in moderately thick shielding cases (5–20 cm). The results provide a practical and reliable tool, as well as a semi-empirical theoretical basis, for fast and accurate engineering estimation of polyethylene-based fast neutron shielding.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Shielding Materials Analysis · Radiation Therapy and Dosimetry · Nuclear Physics and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Rocket Force University of Engineering, Xi’an 710025, China

References (22)

Show source-provided references
1. Current State of Development of Industrial Power Complexes with Fast Neutron Reactors10.1016/j.nucengdes.2021.111547 ↗
2. Image Enhancement Using an Improved Adaptive Contrast Enhancement Algorithm in Neutron Radiography10.1063/5.0157479 ↗
3. Neutron Dosimetry with a Pair of TLDs for the Elekta Precise Medical Linac and the Evaluation of Optimum Moderator Thickness for the Conversion of Fast to Thermal Neutrons10.1016/j.net.2023.11.014 ↗
4. Evaluation of the Medical Staff Effective Dose during Boron Neutron Capture Therapy Using Two High Resolution Voxel-Based Whole Body Phantoms10.1016/j.net.2017.06.011 ↗
5. A New Environmental Dosimeter with Imaging Plates for the Fast Neutron Monitoring10.1016/j.nimb.2004.10.078 ↗
6. Determination of Fe and Tb Concentrations in Geological and Environmental Samples Using the Instrumental Neutron Activation Analysis Method Combined with the γ − γ Coincidence Technique10.1016/j.radphyschem.2022.110203 ↗
7. Monte Carlo Analysis of Tagged Neutron Beams for Cargo Container Inspection10.1016/j.apradiso.2007.06.009 ↗
8. D–T Neutron Generators as a Feasibility Tool for Landmine Detection Based on Neutron Backscattering Method10.1016/j.anucene.2013.11.030 ↗
9. Recent Advances in Fast Neutron Radiography for Cargo Inspection10.1016/j.nima.2007.05.195 ↗
10. Effects of Neutron, γ-Ray, and Neutron–γ-Ray Mixed Radiations on Chromosomal Aberrations in Peripheral Blood Lymphocytes of Two Males10.1093/rpd/ncaf056 ↗
11. The Effect of Incorporated Recycled Low Density Polyethylene (LDPE) on the Fast Neutron Shielding Behaviour (FNSB) of Clay Matrix Using MCNP and PHITS Monte Carlo Codes10.1016/j.radphyschem.2021.109351 ↗
12. Comprehensive Evaluation of Epoxy/Li2B4O7 Composite for Neutron Shielding: Experimental Characterization and Geant4 Simulation Analysis10.1016/j.radphyschem.2025.113433 ↗
13. Probabilistic Modeling and Structural Reliability Based Monte Carlo Simulation: A Case Study10.14445/22315381/IJETT-V72I5P133 ↗
14. Fernandes, J.C.L., Borges, V., Vilhena, M.T., and Ernest, B. (2011, January 24–28). Determination of Neutron Buildup Factor Using Analytical Solution of One-Dimensional Neutron Diffusion Equation in Cylindrical Geometry. Proceedings of the 2011 International Nuclear Atlantic Conference (INAC 2011), Belo Horizonte, MG, Brazil.
15. Attenuation of Neutron and Photon-Induced Irradiation Damage in Pressurized Water Reactor Pressure Vessels10.1016/j.anucene.2020.107601 ↗
16. Phenomenological Calculations of Shielding Spallation Neutron Sources10.1016/j.nima.2013.02.023 ↗
17. Cacuci, D.G. (2010). Handbook of Nuclear Engineering, Springer.10.1007/978-0-387-98149-9 ↗
18. Shams, A., Al-Athel, K., Tiselj, I., Pautz, A., and Kwiatkowski, T. (2024). Characterization of the Direct and Scattered Neutron Flux Around Cyclotron Target. Proceedings of the Challenges and Recent Advancements in Nuclear Energy Systems, Springer Nature.10.1007/978-3-031-64362-0 ↗
19. Development of Lightweight and Highly Efficient Fast Neutrons Composites Shields Based on Epoxy, UHMWPE Fibres and Boron Carbide Particles10.1016/j.radphyschem.2021.109510 ↗
20. Conversion Coefficients for Use in Radiological Protection Against External Radiation
21. Comparison of Different Methods of Estimating the Effective Dose and the Ambient Dose Equivalent for Neutrons from Measured Prompt Gamma Intensities10.1016/j.nima.2021.165072 ↗
22. Scattering Correction in Fast Neutron Radiography Based on Gaussian Fitting Model of Point Scattered Function10.1016/j.net.2025.103980 ↗