Integrated Assessment of Odour Emissions from a Municipal Wastewater Pumping Station Using Field Olfactometry and Chemometric Modelling
Source abstract
Abstract
Odour emissions from wastewater infrastructure represent a significant environmental and social challenge in urban areas. This study evaluates the odour impact of a municipal wastewater pumping station using an integrated field-based approach that combines sensory observations, chemical measurements and meteorological data. Field olfactometry and on-site gas monitoring were applied over a two-year campaign covering different operational and seasonal conditions. The results indicate that odour perception is strongly influenced by hydrogen sulphide concentration, air temperature and wind speed, with short-term high-intensity episodes playing a disproportionate role in odour nuisance. To support integrated interpretation, a Synthetic Odour Index (SOI) was developed to consolidate chemical, sensory and microclimatic information into a single numerical indicator, extending existing odour indices by explicitly integrating field-based sensory and meteorological data. The SOI showed a moderate but statistically significant association with odour intensity (r ≈ 0.3) and effectively differentiated low- and high-nuisance conditions. The proposed methodology demonstrates the value of combining field measurements with integrated data analysis for assessing and managing odour emissions from urban wastewater pumping stations and provides a practical basis for operational monitoring and odour mitigation strategies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Odor and Emission Control Technologies · Insect Pheromone Research and Control · Air Quality Monitoring and Forecasting
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Environmental Engineering, Warsaw University of Technology, Nowowiejska 20 St., 00-653 Warsaw, Poland
Miejskie Przedsiębiorstwo Oczyszczania w m.st. Warszawie Sp. z o.o., Obozowa 43 St., 01-161 Warsaw, Poland
References (57)
Show source-provided references
1. Assessment of hydrogen sulfide emission in a wastewater pumping station10.1007/s10661-021-09116-9 ↗
2. Odor emissions from domestic wastewater: A review10.1080/10643389.2017.1386952 ↗
3. Kulig, A., Szyłak-Szydłowski, M., and Wiśniewska, M. (2022). Application of Field Olfactometry to Monitor the Odour Impact of a Municipal Sewage System. Energies, 15.10.3390/en15114015 ↗
4. Effect of variation in temperature on malodor generation from different units of a wastewater treatment plant10.1007/s11356-025-36110-2 ↗
5. Characterization and prediction of odours from municipal sewage treatment plant
6. Integrated model for estimating odor emissions from civil wastewater treatment plants
7. Modelling of hydrogen sulfide fate and emissions in extended aeration sewage treatment plant using TOXCHEM simulations10.1038/s41598-020-79395-8 ↗
8. Diffusion Behavior and Environmental Impact of Odorants and TVOCs Detected in a Wastewater Treatment Plant for Collaborative Leachate Treatment in Northwest China10.1016/j.chemosphere.2024.143561 ↗
9. Urban sewage treatment odor gas release characteristics and regional differences
10. Constantin, C., Modrogan, C., Dǎncilǎ, A., Gavrila, G., Calinescu, S., Cirstea, A., Danciulescu, V., Tanase, G., and Vasile, G.G. (2025). Dispersion Modeling of Odor Emissions from Area Sources in a Municipal Wastewater Treatment Plant. Atmosphere, 16.10.3390/atmos16050577 ↗
11. Odour emissions from wastewater pumping stations: Characterization and impact assessment using dynamic olfactometry and dispersion modelling
12. Wiśniewska, M., and Szyłak-Szydłowski, M. (2021). The Air and Sewage Pollutants from Biological Waste Treatment. Processes, 9.10.3390/pr9020250 ↗
13. On the relation between odour intensity and concentration
14. Comparison of two types of field olfactometers for assessing odours in laboratory and field tests
15. Odor mapping of an urban waste management plant: Chemometric approach and correlation between physico-chemical, respirometric and olfactometric variables10.1016/j.jclepro.2018.11.109 ↗
16. An advanced odour monitoring approach based on citizens science: A real application in Southern Italy
17. Wysocka, I., and Dębowski, M. (2025). Advantages and Limitations of Measurement Methods for Assessing Odour Nuisance in Air—A Comparative Review. Appl. Sci., 15.10.3390/app15105622 ↗
18. Data Driven Analysis of Urban Odour Perception: Geospatial Insights from Hong Kong10.1016/j.apgeog.2025.103844 ↗
19. Cangialosi, F., Bruno, E., and De Santis, G. (2021). Application of Machine Learning for Fenceline Monitoring of Odor Classes and Concentrations at a Wastewater Treatment Plant. Sensors, 21.10.3390/s21144716 ↗
20. Predicting odor concentration for environmental sustainability: A comparison among machine learning methods
21. Determination of the relationship between sewage odour and BOD by neural networks10.1016/j.envsoft.2004.04.012 ↗
22. Deep neural networks for odour source prediction using multi-sensor data
23. Integrated chemometric and olfactometric approach for real-time odour monitoring in urban sewage systems
24. Advances in electronic nose technologies for odour monitoring in wastewater facilities
25. Measuring odors in the environment vs. dispersion modelling: A review10.1016/j.atmosenv.2013.07.029 ↗
26. Odour Emission Inventory and Management in Wastewater Treatment Plants
27. Kulig, A., and Szyłak-Szydłowski, M. (2019). Assessment of the effects of Wastewater Treatment Plant modernization by means of the field olfactometry method. Water, 11.10.3390/w11112367 ↗
28. Validation of Odor Concentration from Mechanical-Biological Treatment Piles Using Static Chamber and Wind Tunnel with Different Wind Speed Values10.1080/10962247.2017.1338632 ↗
29. Szyłak-Szydłowski, M., and Kulig, A. (2024). Deodorisation of Ventilated Air from a Fat-Processing Plant Using Different Types of Biofilter Fillings and Membranes. Sustainability, 16.10.3390/su16051939 ↗
30. Szyłak-Szydłowski, M., Kos, W., Tarakowski, R., Tkaczyk, M., and Borowik, P. (2025). Assessment of odour emission during the composting process by using olfactory methods and gas sensor array measurements. Sensors, 25.10.3390/s25103153 ↗
31. Szyłak-Szydłowski, M., and Kos, W. (2025). Odorous emissions during the use of the intermediate fraction as an additive to the green waste composting process. Sustainability, 17.10.3390/su17030851 ↗
32. James, G., Witten, D., Hastie, T., and Tibshirani, R. (2021). An Introduction to Statistical Learning: With Applications in R, Springer. [2nd ed.].10.1007/978-1-0716-1418-1 ↗
33. Wood, S.N. (2017). Generalized Additive Models: An Introduction with R, Chapman and Hall/CRC. [2nd ed.].10.1201/9781315370279 ↗
34. Shape Constrained Additive Models10.1007/s11222-013-9448-7 ↗
35. Natural gas odorants: A scoping review of health effects
36. Burgués, J., Esclapez, M., Doñate, S., Pastor, L., and Marco, S. (2021). Aerial Mapping of Odorous Gases in a Wastewater Treatment Plant Using a Small Drone. Remote. Sens., 13.10.3390/rs13091757 ↗
37. Implementation of an electronic nose for real -time identification of odour emission peaks at a wastewater treatment plant10.1016/j.heliyon.2023.e20437 ↗
38. Odour mapping and air quality analysis of a wastewater treatment plant at a seaside tourist area10.1007/s10661-023-11598-8 ↗
39. Odour impact assessment by considering short-term ambient concentrations: A multi-model and two-site comparison10.1016/j.envint.2020.105990 ↗
40. Czarnota, J., Masłoń, A., and Pajura, R. (2023). Wastewater Treatment Plants as a Source of Malodorous Substances Hazardous to Health, Including a Case Study from Poland. Int. J. Environ. Res. Public Health, 20.10.3390/ijerph20075379 ↗
41. Odor-causing volatile organic compounds in wastewater treatment plant units and sludge management areas10.1080/10934520802293776 ↗
42. Park, S. (2020). Odor Characteristics and Concentration of Malodorous Chemical Compounds Emitted from a Combined Sewer System in Korea. Atmosphere., 11.10.3390/atmos11060667 ↗
43. Field application of cost-effective sensors for the monitoring of NH3, H2S, and TVOC in environmental treatment facilities and the estimation of odor intensity10.1080/10962247.2022.2131652 ↗
44. Characterization of odorous compounds and odor load in indoor air of modern complex MBT facilities10.1016/j.cej.2016.11.026 ↗
45. Widespread Inhibition, Antagonism, and Synergy in Mouse Olfactory Sensory Neurons In Vivo10.1016/j.celrep.2020.107814 ↗
46. Takeshi, I. (2022). Mechanisms of odor mixture responses in the olfactory system. Proc. Annu. Meet. Jpn. Pharmacol. Soc.10.1254/jpssuppl.95.0_3-S29-5 ↗
47. Antagonistic interactions between odorants alter human odor perception10.1016/j.cub.2023.04.072 ↗
48. Emission characteristics of odorous volatile sulfur compound from a full-scale sequencing batch reactor wastewater treatment plant10.1016/j.scitotenv.2021.145991 ↗
49. Atmospheric parameters play an important role in driving hydrogen sulphide concentrations in ambient air near waste management centres10.1007/s10661-023-12047-2 ↗
50. Experimental evaluation on liquid area sources: Influence of wind velocity and temperature on the wind tunnel sampling of VOCs emissions from wastewater treatment plants10.1016/j.chemosphere.2022.137337 ↗
51. Franchina, C., Cefalì, A., Gianotti, M., Frugis, A., Corradi, C., De Prosperis, G., Ronzio, D., Ferrero, L., Bolzacchini, E., and Cipriano, D. (2024). Innovative Approaches to Industrial Odour Monitoring: From Chemical Analysis to Predictive Models. Atmosphere, 15.10.3390/atmos15121401 ↗
52. Dobrzyniewski, D., Szulczyński, B., and Gębicki, J. (2022). Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix. Molecules, 27.10.3390/molecules27134180 ↗
53. Machine-Learning-Based Olfactometer: Prediction of Odor Perception from Physicochemical Features of Odorant Molecules10.1021/acs.analchem.7b02389 ↗
54. Assessment of odor activity value coefficient and odor contribution based on binary interaction effects in waste disposal plant10.1016/j.atmosenv.2014.12.045 ↗
55. Odor concentration (OC) prediction based on odor activity values (OAVs) during composting of solid wastes and digestates10.1016/j.atmosenv.2018.12.030 ↗
56. Evaluation of the chemical composition and correlation between the calculated and measured odour concentration of odorous gases from a landfill in Beijing, China10.1016/j.atmosenv.2017.06.010 ↗
57. Yan, L., Liu, J., and Fang, D. (2015). Use of a Modified Vector Model for Odor Intensity Prediction of Odorant Mixtures. Sensors, 15.10.3390/s150305697 ↗