journal article·2025-12-22Open access

Are We Really Training at the Desired Intensity? Concurrent Validity of 16 Commercial Photoplethysmography-Based Heart Rate Monitors

Pablo Oropesa, Alejandro Sánchez-Pay, Elena Conesa-Ros, Antonino Bianco, Jesús J. Ruiz-Navarro, Alejandro Martínez-Cava

Applied Sciences· Volume 16· Issue 1

Abstract

The validity and accuracy of photoplethysmography (PPG)-based wearable heart rate (HR) monitors remain debatable. This study aimed to determine the concurrent validity of HR records from a wide range of contemporary PPG monitors across the full spectrum of exercise intensities and running conditions. Ten well-trained male endurance athletes performed several incremental maximal aerobic (IMA) tests and high-intensity interval training (HIIT) sessions while wearing a Polar H9 chest strap, as the reference criterion; 16 PPG-based heart rate monitors were tested (Amazfit Fit5; Apple Ultra and SE; Garmin 35, 45, 235, and 935; Polar M200, M430, OH1, Vantage M, Vantage V, Vantage V3, and Verity Sense; Galaxy Watch 5, Suunto 3 Fitness). The results showed excellent ICC (>0.90) versus the reference device across IMA and HIIT tests. Overall, the ICC decreased, and magnitudes of error increased (BIAS, SEM, and CV) as the intensity increased. Moreover, lower ICC values and greater BIAS, SEM, and CV were observed during the HIIT compared to the IMA test. Nevertheless, notable differences between devices were observed in magnitude of errors, accuracy, data loss, and read failures. In conclusion, PPG-based HR monitor validity is device-dependent and therefore exercise data from running training and competitions should be interpreted with caution.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Heart Rate Variability and Autonomic Control · Cardiovascular and exercise physiology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, 30700 Murcia, Spain

Performance Analysis and Biomechanics in Sport, Department of Physical Activity and Sport, Faculty of Sport Sciences, University of Murcia, 30700 Murcia, Spain

Sport and Exercise Sciences Research Unit, Department of Psychology, Educational Science and Human Movement, University of Palermo, 90133 Palermo, Italy

Aquatics Lab, Department of Physical Education and Sports, Faculty of Sport Sciences, University of Granada, 18071 Granada, Spain

Funding

CAR Region de Murcia

References (38)

Show source-provided references
1. Heart Rate Monitoring Applications and Limitations10.2165/00007256-200333070-00004 ↗
2. Quantifying training intensity distribution in elite endurance athletes: Is there evidence for an “optimal” distribution?10.1111/j.1600-0838.2004.00418.x ↗
3. How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?10.1136/bmjsem-2015-000106 ↗
4. Validation of photoplethysmography as a method to detect heart rate during rest and exercise10.3109/03091902.2015.1047536 ↗
5. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/R01 ↗
6. Commercial Smart Watches and Heart Rate Monitors: A Concurrent Validity Analysis10.1519/JSC.0000000000004482 ↗
7. Alugubelli, N., Abuissa, H., and Roka, A. (2022). Wearable Devices for Remote Monitoring of Heart Rate and Heart Rate Variability—What We Know and What Is Coming. Sensors, 22.10.3390/s22228903 ↗
8. Comparison between photoplethysmographic heart rate monitor from Polar Vantage M and Polar V800 with H10 chest strap while running on a treadmill: Validation of the Polar Precision Prime™ photoplestimographic system
9. The Polar® OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise10.1055/a-0631-0920 ↗
10. Validity of the polar verity sense during swimming at different locations and intensities10.1111/sms.14494 ↗
11. Hettiarachchi, I.T., Hanoun, S., Nahavandi, D., and Nahavandi, S. (2019). Validation of Polar OH1 optical heart rate sensor for moderate and high intensity physical activities. PLoS ONE, 14.10.1371/journal.pone.0217288 ↗
12. Navalta, J.W., Montes, J., Bodell, N.G., Salatto, R.W., Manning, J.W., and DeBeliso, M. (2020). Concurrent heart rate validity of wearable technology devices during trail running. PLoS ONE, 15.10.1371/journal.pone.0238569 ↗
13. Validation of biofeedback wearables for photoplethysmographic heart rate tracking
14. Validity of the Polar V800 monitor for measuring heart rate variability in mountain running route conditions10.1007/s00421-018-3808-0 ↗
15. Evaluation of Earbud and Wristwatch Heart Rate Monitors during Aerobic and Resistance Training10.70252/LOOX1045 ↗
16. Accuracy of the wearable activity tracker Garmin Forerunner 235 for the assessment of heart rate during rest and activity10.1080/02640414.2018.1535563 ↗
17. Estimating accuracy at exercise intensities: A comparative study of self-monitoring heart rate and physical activity wearable devices10.2196/mhealth.7043 ↗
18. Accuracy of wrist-worn heart rate monitors10.1001/jamacardio.2016.3340 ↗
19. How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram10.1016/j.ijcard.2012.03.119 ↗
20. Defining training and performance caliber: A participant classification framework10.1123/ijspp.2021-0451 ↗
21. A New Short Track Test to Estimate the VO2max and Maximal Aerobic Speed in Well-Trained Runners10.1519/JSC.0000000000003121 ↗
22. RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise10.1007/s00421-019-04142-5 ↗
23. A 1% treadmill grade most accurately reflects the energetic cost of outdoor running10.1080/02640419608727717 ↗
24. Cerezuela-Espejo, V., Courel-Ibáñez, J., Morán-Navarro, R., Martínez-Cava, A., and Pallarés, J.G. (2018). The relationship between lactate and ventilatory thresholds in runners: Validity and reliability of exercise test performance parameters. Front. Physiol., 9.10.3389/fphys.2018.01320 ↗
25. High-intensity interval training, solutions to the programming puzzle: Part I: Cardiopulmonary emphasis10.1007/s40279-013-0029-x ↗
26. Pallarés, J.G., Morán-Navarro, R., Ortega, J.F., Fernández-Elías, V.E., and Mora-Rodriguez, R. (2016). Validity and reliability of ventilatory and blood lactate thresholds in well-trained cyclists. PLoS ONE, 11.10.1371/journal.pone.0163389 ↗
27. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research10.1016/j.jcm.2016.02.012 ↗
28. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine10.2165/00007256-199826040-00002 ↗
29. Measures of Reliability in Sports Medicine and Science10.2165/00007256-200030050-00006 ↗
30. Reproducibility and Repeatability of Five Different Technologies for Bar Velocity Measurement in Resistance Training10.1007/s10439-019-02265-6 ↗
31. Icenhower, A., Murphy, C., Brooks, A.K., Irby, M., N’dah, K., Robison, J., and Fanning, J. (2025). Investigating the accuracy of Garmin PPG sensors on differing skin types based on the Fitzpatrick scale: Cross-sectional comparison study. Front. Digit. Health, 7.10.3389/fdgth.2025.1553565 ↗
32. Wrist-worn devices for the measurement of heart rate and energy expenditure: A validation study for the Apple Watch 6, Polar Vantage V and Fitbit Sense10.1080/17461391.2021.2023656 ↗
33. Shcherbina, A., Mikael Mattsson, C., Waggott, D., Salisbury, H., Christle, J.W., Hastie, T., Wheeler, M.T., and Ashley, E.A. (2017). Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J. Pers. Med., 7.10.3390/jpm7020003 ↗
34. Variable accuracy of wearable heart rate monitors during aerobic exercise10.1249/MSS.0000000000001284 ↗
35. Olstad, B.H., and Zinner, C. (2020). Validation of the Polar OH1 and M600 optical heart rate sensors during front crawl swim training. PLoS ONE, 15.10.1371/journal.pone.0231522 ↗
36. Investigating sources of inaccuracy in wearable optical heart rate sensors10.1038/s41746-020-0226-6 ↗
37. Wrist-worn wearables for monitoring heart rate and energy expenditure while sitting or performing light-to-vigorous physical activity: Validation study10.2196/16716 ↗
38. A review on wearable photoplethysmography sensors and their potential future applications in health care