journal article·2025-11-06Open access

Cuff-Less Estimation of Blood Pressure and Detection of Hypertension/Arteriosclerosis from Fingertip PPG Using Machine Learning: An Experimental Study

Marco Antonio Arroyo-Ramírez, Isaac Machorro-Cano, Augusto Javier Reyes-Delgado, Jorge Ernesto González-Díaz, José Luis Sánchez-Cervantes

Applied Sciences· Volume 15· Issue 21

Abstract

Worldwide less than half of adults with hypertension are diagnosed and treated (only 42%), in addition one in five adults with hypertension (21%) has the condition under control. In the American continent, cardiovascular diseases (CVD) are the leading cause of death and high blood pressure (hypertension) is responsible for 50% of CVD deaths. Only a few countries show a population hypertension control rate of more than 50%. In this experimental study, we trained 15 regression-type machine learning algorithms, including traditional and ensemble methods to assess their effectiveness in estimating arterial pressure using noninvasive photoplethysmographic (PPG) signals extracted from 110 study subjects, to identify the risk of hypertension and its correlation with arteriosclerosis. We analyzed the performance of each algorithm using the metrics MSE, MAE, RMSE, and r2. A 10-fold cross-validation showed that the best algorithms for hypertension risk identification were LR, KNN, SVR, RF, LR Baggin, KNNBagging, SVRBagging, and DTBagging. On the other hand, the best algorithms for arterioclesrosis risk identification were LR, KNN, SVR, RF, LR Bagging, and DTBagging. These results suggest that this research is promising and offers valuable information on the acquisition and processing of PPG signals. However, as this is an experimental study, the effectiveness of our model needs to be validated with a larger database. On the other hand, this model represents a support tool for healthcare specialists in the early detection of cardiovascular health, allowing people to self-manage their health and seek medical attention at an early stage.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Infrared Thermography in Medicine · Artificial Intelligence in Healthcare

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Tecnológico Nacional de México/I. T. Orizaba, Oriente 9, Orizaba C.P. 94320, Veracruz, Mexico

Universidad del Papaloapan, Circuito Central # 200, ColoniaParque Industrial, San Juan Bautista Tuxtepec C.P. 68301, Oaxaca, Mexico

Funding

Tecnológico Nacional de México (TecNM) Orizaba, México

References (33)

Show source-provided references
1. (2025, August 29). Día Mundial de la Hipertensión 2024—OPS/OMS|Organización Panamericana de la Salud. Available online: https://www.paho.org/es/campanas/dia-mundial-hipertension-2024.
2. (2025, August 28). Cardiovascular Diseases (CVDs). Available online: https://www.who.int/news-room/fact-sheets/detail/cardiovascular-diseases-(cvds).
3. World Health Organization cardiovascular disease risk charts: Revised models to estimate risk in 21 global regions10.1016/S2214-109X(19)30318-3 ↗
4. Urgent need to increase the rates of diagnosing, treating and controlling hypertension in older women: A call for action
5. Hypertension and heart failure10.1016/j.hfc.2019.06.007 ↗
6. Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method10.1016/j.bspc.2018.08.022 ↗
7. Artificial intelligence, machine learning, and cardiovascular disease10.1177/1179546820927404 ↗
8. Poznyak, A.V., Sadykhov, N.K., Kartuesov, A.G., Borisov, E.E., Melnichenko, A.A., Grechko, A.V., and Orekhov, A.N. (2022). Hypertension as a risk factor for atherosclerosis: Cardiovascular risk assessment. Front. Cardiovasc. Med., 9.10.3389/fcvm.2022.959285 ↗
9. Blood pressure and heart failure10.1186/s40885-019-0132-x ↗
10. Tjitra, M.A., Anju, N.E., Sudiana, D., and Rizkinia, M. (2024). A Wireless Noninvasive Blood Pressure Measurement System Using MAX30102 and Random Forest Regressor for Photoplethysmography Signals. Computers, 13.10.3390/computers13050125 ↗
11. Attivissimo, F., D’Alessandro, V.I., De Palma, L., Lanzolla, A.M.L., and Di Nisio, A. (2023). Non-Invasive Blood Pressure Sensing via Machine Learning. Sensors, 23.10.3390/s23198342 ↗
12. Tarifi, B., Fainman, A., Pantanowitz, A., and Rubin, D.M. (2023). A Machine Learning Approach to the Non-Invasive Estimation of Continuous Blood Pressure Using Photoplethysmography. Appl. Sci., 13.10.3390/app13063955 ↗
13. Fleischhauer, V., Feldheiser, A., and Zaunseder, S. (2022). Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation. Sensors, 22.10.3390/s22187037 ↗
14. Estimation and Validation of Arterial Blood Pressure Using Photoplethysmogram Morphology Features in Conjunction With Pulse Arrival Time in Large Open Databases10.1109/JBHI.2020.3009658 ↗
15. Lin, W.-H., Chen, F., Geng, Y., Ji, N., Fang, P., and Li, G. (2021). Towards accurate estimation of cuffless and continuous blood pressure using multi-order derivative and multivariate photoplethysmogram features. Biomed. Signal Process. Control, 63.10.1016/j.bspc.2020.102198 ↗
16. Evdochim, L., Dobrescu, D., Halichidis, S., Dobrescu, L., and Stanciu, S. (2022). Hypertension Detection Based on Photoplethysmography Signal Morphology and Machine Learning Techniques. Appl. Sci., 12.10.3390/app12168380 ↗
17. Yin, S., Li, G., Luo, Y., and Lin, L. (2021). Cuff-less continuous blood pressure measurement based on multiple types of information fusion. Biomed. Signal Process. Control, 68.10.1016/j.bspc.2021.102549 ↗
18. Fati, S.M., Muneer, A., Akbar, N.A., and Taib, S.M. (2021). A Continuous Cuffless Blood Pressure Estimation Using Tree-Based Pipeline Optimization Tool. Symmetry, 13.10.3390/sym13040686 ↗
19. Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., and Fuchs, M. (2021). Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning. Sensors, 21.10.3390/s21186022 ↗
20. Sun, X., Zhou, L., Chang, S., and Liu, Z. (2021). Using CNN and HHT to Predict Blood Pressure Level Based on Photoplethysmography and Its Derivatives. Biosensors, 11.10.3390/bios11040120 ↗
21. Almarshad, M., Islam, M., Al-Ahmadi, S., and BaHammam, A. (2022). Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review. Healthcare, 10.10.3390/healthcare10030547 ↗
22. Machine learning algorithms: A review
23. Assembly algorithms for next-generation sequencing data10.1016/j.ygeno.2010.03.001 ↗
24. A benchmark study of machine learning for analysis of signal feature extraction techniques for blood pressure estimation using photoplethysmography (PPG)10.1109/ACCESS.2021.3117969 ↗
25. (2025, August 29). MAX86150 Datasheet and Product Info|Analog Devices. Available online: https://www.analog.com/en/products/max86150.html.
26. Esgalhado, F., Batista, A., Vassilenko, V., Russo, S., and Ortigueira, M. (2022). Peak detection and HRV feature evaluation on ECG and PPG signals. Symmetry, 14.10.3390/sym14061139 ↗
27. Emerging biomarkers for the detection of cardiovascular diseases10.1186/s43044-022-00317-2 ↗
28. (2025, September 02). Fundación Oftalmológica. Available online: https://fundacionzurita.com.mx/.
29. (2025, August 29). AHA Research Grant Funding Opportunities. Available online: https://professional.heart.org/en/research-programs/aha-funding-opportunities.
30. Carlini, N., Ippolito, D., Lee, K., Tramèr, F., Jagielski, M., and Zhang, C. (2023, January 1–5). Quantifying Memorization Across Neural Language Models. Proceedings of the Eleventh International Conference on Learning Representations (ICLR), Kigali, Rwanda.
31. Dhar, P., Singh, R.V., Peng, K.-C., Wu, Z., and Chellappa, R. (2019, January 15–20). Learning Without Memorizing. Proceedings of the 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), Long Beach, CA, USA.10.1109/CVPR.2019.00528 ↗
32. (2025, August 29). Hipertensión. Available online: https://www.who.int/es/news-room/fact-sheets/detail/hypertension.
33. (2025, August 29). Módulo de Biosensores Integrado de PPG y ECG Para Dispositivos Móviles MAX86150. Available online: https://www.digikey.com.mx/es/product-highlight/m/maxim-integrated/max86150-integrated-ppg-and-ecg-biosensor-module.