journal article·2025-10-13Open access

Shock Absorption Control of Sand-Layer Isolation Liquid Storage Structure with Soft Steel

Hulin Zhang, Yiting Mu, Kai Ding, Xuansheng Cheng

Applied Sciences· Volume 15· Issue 20

Abstract

Wall plate rupture in liquid storage structures (LSSs) induced by earthquakes is a prevalent issue. To mitigate the impacts of seismic hazards on plate–shell composite concrete liquid storage structures (CLSSs), in this study, we propose an investigation into X-type mild steel–Shape Memory Alloy (SMA) seismic mitigation control for plate–shell composite CLSSs with sand-layer seismic isolation. Via finite element parametric analysis, this study examines the effects of two key parameters—the sand-layer friction coefficient and the spring-damping ratio of X-type mild steel–SMA seismic mitigation elements—on the dynamic response of CLSSs. The results indicate the following: under unidirectional seismic excitation, the proposed mitigation method achieves a favorable control effect on the maximum principal stress of the structure; under bidirectional seismic excitation, the optimal control effect on the maximum principal stress is achieved when the spring-damping ratio of the mitigation elements is 0.3 and the friction coefficient of the seismic isolation sand layer is 0.4. Additionally, under both unidirectional and bidirectional seismic excitation, this method exhibits a noticeable control effect on the peak liquid sloshing height.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fluid Dynamics Simulations and Interactions · Vibration Control and Rheological Fluids · Earthquake and Tsunami Effects

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory of Disaster Prevention and Mitigation in Civil Engineering of Gansu Province, Lanzhou University of Technology, Lanzhou 730050, China

Western Engineering Research Center of Disaster Mitigation in Civil Engineering of Ministry of Education, Lanzhou University of Technology, Lanzhou 730050, China

Funding

National Natural Science Foundation of China

References (21)

Show source-provided references
1. Cao, R.F. (2022). Dynamic Analysis on the Performance of Seismic Mitigation and Isolation Technology in Frame-Shear Wall Structures. [Master’s Thesis, North China University of Water Resources and Electric Power].
2. Design of re-centering spring for flat sliding base isolation system: Theory and a numerical study10.1016/j.engstruct.2016.07.049 ↗
3. Reduced Sloshing Effect in Steel Tanks10.1007/s13296-022-00652-9 ↗
4. Seismic reliability of spherical containers retrofitted by means of energy dissipation devices10.1016/j.engstruct.2011.05.015 ↗
5. Fluid-structure interactive seismic response and vibration dissipation method of spherical liquid -storage tank
6. A Study of fluid-structure interaction dynamic response for reinforced liquid storage tank with internal components
7. Parametric research on seismic response of large scale liquid storage tank isolated by lead-rubber bearings
8. Evaluation of the performance of a sliding-type base isolation system with a NiTi shape memory alloy device considering temperature effects10.1016/j.engstruct.2009.09.010 ↗
9. Seismic Failure Mechanism of Plate-Shell Integrated Concrete Liquid Storage Structure10.1007/s12205-023-0991-2 ↗
10. Qi, L. (2021). Seismic Failure Mechanism and Isolation Control of Plate-Shell Integrated Concrete Liquid Storage Structure. [Master’s Thesis, Lanzhou University of Technology].
11. On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions10.1016/j.soildyn.2010.04.008 ↗
12. A coupled BE-FE study for evaluation of seismically isolated cylindrical liquid storage tanks considering fluid-structure interaction10.1016/j.jfluidstructs.2008.07.005 ↗
13. Seismic analysis of base-isolated liquid storage tanks10.1016/S0022-460X(03)00749-1 ↗
14. Simplified mechanical model for vibration isolation analysis of a vertical storage tank considering swinging effect
15. Numerical analysis of the base-isolated rectangular storage tanks under bi-directional seismic excitation10.9734/BJMCS/2014/11299 ↗
16. Rubber-sand infilled soilbags as seismic isolation cushions: Experimental validation10.1680/jgein.23.00158 ↗
17. Wang, H.G., Wei, L., and Qiu, H.B. (2013). Experimental study on isolation performance of sand cushion and sand grains slip. Low Temp. Archit. Technol., 35.
18. Wu, J.Y., Yu, Q.Q., Gu, X.L., and Zhou, F.Y. (2024). Seismic response analysis of large-scale lng storage tanks isolated by innovative isolation devices under near-fault earthquakes. Eng. Mech., 1–19.
19. Shaking table tests on the seismic performances of rural buildings with isolated sand cushion
20. Earthquake response analysis of spherical tanks with seismic isolation10.1016/j.proeng.2011.07.236 ↗
21. Zheng, J.J. (2018). Dynamic Response Analysis of Three Dimensional Isolation of Large Scale Storage Tank Under the Action of Near Field Earthquake. [Master’s Thesis, Guangzhou University].