journal article·2025-10-09Open access

High-Intensity Focused Pressure Wave Generation via Q-Switched Er:YAG Laser with a Water Layer Formed by the Coupled Lens for Optoacoustic Conversion

Dominik Šavli, Aleš Babnik, Daniele Vella, Matija Jezeršek

Applied Sciences· Volume 15· Issue 19

Abstract

We demonstrate coating-free optoacoustic generation and focusing of ultrasound using a mechanically Q-switched (MQS) erbium-doped yttrium aluminum garnet (Er:YAG) source (~100 ns, ≤20 mJ) combined with a concave water interface that simultaneously serves as converter and acoustic lens. Axial, lateral, and focal-point measurements mapped the pressure field while varying beam diameter (2w = 5–15 mm) and pulse energy (E = 10–20 mJ). The maximum focal positive pressure (Pmax = 7 MPa) occurs at an intermediate diameter (~10 mm), whereas the tightest lateral/axial confinement and strongest spectral enhancement arise at larger diameters (14–15 mm) with fc = ~5 MHz and −6 dB bandwidth up to 7 MHz. Pressure increases nearly monotonically with energy. For equal fluence, larger diameters yield higher focal pressures due to greater focusing gain. Small beams (2w ≈ 5–7 mm) show shorter apparent time-of-flight (TOF) and waveform broadening, consistent with early shock-like emission from locally vaporizing region. These results provide practical rules for tuning amplitude, spectrum, and confinement, enabling sub-millimeter focusing for contamination-sensitive and therapeutic applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Laser Design and Applications · Solid State Laser Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva ulica 6, 1000 Ljubljana, Slovenia

Funding

The Slovenian Research and Innovation Agency · national program · European Union–NextGenerationEU

References (40)

Show source-provided references
1. High intensity focused ultrasound in clinical tumor ablation10.5306/wjco.v2.i1.8 ↗
2. High-intensity focused ultrasound in the treatment of solid tumours10.1038/nrc1591 ↗
3. High-Intensity Focused Ultrasound: Current Potential and Oncologic Applications10.2214/AJR.07.2671 ↗
4. High intensity focused ultrasound lithotripsy with cavitating microbubbles10.1007/s11517-009-0471-y ↗
5. Enhanced Sonothrombolysis Induced by High-Intensity Focused Acoustic Vortex10.1016/j.ultrasmedbio.2022.05.021 ↗
6. Localized micro-scale disruption of cells using laser-generated focused ultrasound10.1002/jbio.201200247 ↗
7. Generation of a focused pressure wave and localized cavitation clouds using a metal-semiconductor Ti/black-TiOx optoacoustic lens10.1016/j.rinp.2020.103721 ↗
8. Efficient decoration of graphene oxide with a narrow size distribution of noble metal nanoparticles: Green reduction and integration into a thermoelastic composite10.1016/j.synthmet.2025.117894 ↗
9. Picosecond photoacoustic generation of ultrasounds with composites of graphene-decorated gold nanoparticles10.1016/j.nanoen.2024.110236 ↗
10. Ultrasonic photoacoustic emitter of graphene-nanocomposites film on a flexible substrate10.1016/j.pacs.2022.100413 ↗
11. Transdermal drug delivery with a pressure wave10.1016/j.addr.2003.10.031 ↗
12. Amplification of high-intensity pressure waves and cavitation in water using a multi-pulsed laser excitation and black-TiOx optoacoustic lens10.1364/BOE.460713 ↗
13. Dynamic acoustic focusing in photoacoustic transmitter10.1016/j.pacs.2020.100224 ↗
14. Fully planar laser-generated focused ultrasound transmitter10.1016/j.sna.2022.113929 ↗
15. Pereira, D.A., Silva, A.D., Martins, P.A.T., Piedade, A.P., Martynowych, D., Veysset, D., Moreno, M.J., Serpa, C., Nelson, K.A., and Arnaut, L.G. (2021). Imaging of photoacoustic-mediated permeabilization of giant unilamellar vesicles (GUVs). Sci. Rep., 11.10.1038/s41598-021-82140-4 ↗
16. Silva, A.D., Serpa, C., and Arnaut, L.G. (2019). Photoacoustic transfection of DNA encoding GFP. Sci. Rep., 9.10.1038/s41598-018-37759-1 ↗
17. Non-genetic photoacoustic stimulation of single neurons by a tapered fiber optoacoustic emitter10.1038/s41377-021-00580-z ↗
18. Laser-Induced Focused Ultrasound for Cavitation Treatment: Toward High-Precision Invisible Sonic Scalpel10.1002/smll.201701555 ↗
19. A practical guide to photoacoustic tomography in the life sciences10.1038/nmeth.3925 ↗
20. Looking at sound: Optoacoustics with all-optical ultrasound detection10.1038/s41377-018-0036-7 ↗
21. Measurement of Simulated Debris Removal Rates in an Artificial Root Canal to Optimize Laser—Activated Irrigation Parameters10.1002/lsm.23297 ↗
22. Measurement of Pressures Generated in Root Canal During Er:YAG Laser-Activated Irrigation
23. Amplification of pressure waves in laser-assisted endodontics with synchronized delivery of Er:YAG laser pulses10.1007/s10103-017-2435-z ↗
24. The effect of surface roughness on the Er:YAG laser-induced photoacoustic removal of bacteria in zero-gap periodontal/peri-implant pocket model10.1016/j.ultsonch.2025.107458 ↗
25. Volk, M., Šavli, D., Molan, K., Terlep, S., Levičnik-Höfferle, Š., Trost, M., Gašpirc, B., Lukač, M., Jezeršek, M., and Stopar, D. (2025). Er:YAG laser biofilm removal from zero-gap periodontal/peri-implant model system mimicking clinical attachment loss. J. Biomed. Opt., 30.10.1117/1.JBO.30.2.025002 ↗
26. Biofilm removal from Difficult-to-Reach places via secondary cavitation within a constrained geometry mimicking a Periodontal/Peri-Implant pocket10.1016/j.ultsonch.2024.106832 ↗
27. Rotating-Mirror Q-Switched Er:YAG Laser for Optodynamic Studies10.5545/sv-jme.2010.120 ↗
28. High energy (0.8 J) mechanically Q-switched 2.94 μm Er:YAG laser10.1364/OE.417301 ↗
29. Koranda, P., Nemec, M., Jelínková, H., Šulc, J., and Cech, M. (2005, January 6–9). Electro-Optically Q-Switched Er:YAG laser. Proceedings of the Advanced Solid-State Photonics (TOPS), Vienna Austria.10.1364/ASSP.2005.359 ↗
30. High peak power Q-switched Er:YAG laser with two polarizers and its ablation performance for hard dental tissues10.1364/OE.22.015686 ↗
31. Low f-number photoacoustic lens for tight ultrasonic focusing and free-field micro-cavitation in water10.1063/1.4943369 ↗
32. Laser generated ultrasound sources using carbon-polymer nanocomposites for high frequency metrology10.1121/1.5048413 ↗
33. Kurz, T., Parlitz, U., Kaatze, U., and Georg-August-Universität Göttingen (2007). Oscillations, Waves, and Interactions: Sixty Years Drittes Physikalisches Institut: A Festschrift, Univ.-Verl. Göttingen.10.17875/gup2007-97 ↗
34. Nanodroplet vaporization with pulsed-laser excitation repeatedly amplifies photoacoustic signals at low vaporization thresholds10.1039/D3RA05639B ↗
35. An experimental study on the cavitation of water with dissolved gases10.1007/s00348-017-2449-0 ↗
36. Overview of experimental studies of biological effects of medical ultrasound caused by gas body activation and inertial cavitation10.1016/j.pbiomolbio.2006.07.027 ↗
37. Mechanical index10.5152/akd.2015.6061 ↗
38. Comparing safety and efficacy of acoustic subcision at two different rapid acoustic pulse rates to improve the appearance of cellulite10.1002/lsm.23718 ↗
39. Focused Ultrasound Hyperthermia for Targeted Drug Release from Thermosensitive Liposomes: Results from a Phase I Trial10.1148/radiol.2018181445 ↗
40. Kim, J., Chang, W.-Y., Lindsey, B.D., Dayton, P.A., Dai, X., Stavas, J.M., and Jiang, X. (2016, January 18–21). Laser-Generated-Focused Ultrasound Transducers for Microbubble-Mediated, Dual-Excitation Sonothrombolysis. Proceedings of the 2016 IEEE International Ultrasonics Symposium (IUS), Tours, France.10.1109/ULTSYM.2016.7728473 ↗