Reconstruction and Parametric Recognition of Endodontic Files from CT Scans for Design Modification and FEM Analysis
Source abstract
Abstract
Endodontic rotary file geometries are often obtained using computed tomography (CT) scans, which produce 3D models comprising point clouds and triangulated surfaces. Despite being widely used, this approach has significant limitations; scanned geometries may deviate from the theoretical design due to physical deformation during manipulation, inaccuracies due to the scanner resolution, and the non-parametric nature of the resulting mesh, preventing design modification or parameter extraction. This study proposes a methodology to overcome these limitations by recognizing and reconstructing the scanned geometry. This process involves correcting deformation caused by flexion, applying filtering techniques to minimize scan-induced noise, and identifying key geometric parameters. This enables the generation of a manipulable and accurate CAD model which not only preserves the original design intention but also allows for parametric modifications and advanced finite element analysis. The proposed method bridges the gap between real geometry acquisition and design-based simulation, providing a powerful tool for endodontic instrument evaluation and optimization.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Drilling and Well Engineering · Dental Radiography and Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12007 Castelló, Spain
Faculty of Odonthology, Alfonso X University, 28691 Madrid, Spain
Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain
References (35)
Show source-provided references
1. Finite element design optimisation by DOE technique of the torsional stress behaviour for NiTi rotary endodontic instruments10.1007/s00170-024-14956-z ↗
2. A study on the influence of Ni-Ti M-Wire in the flexural fatigue life of endodontic rotary files by using Finite Element Analysis10.1016/j.msec.2014.03.061 ↗
3. Roda-Casanova, V., Zubizarreta-Macho, A., Sanchez-Marin, F., Ezpeleta, O.A., Martínez, A.A., and Catalán, A.G. (2021). Computerized generation and finite element stress analysis of endodontic rotary files. Appl. Sci., 11.10.3390/app11104329 ↗
4. Roda-Casanova, V., and Pérez-González, A. (2024). Computerized Generation of Endodontic Files by Reproducing the Flute Grinding Manufacturing Process. Bioengineering, 11.10.3390/bioengineering11080751 ↗
5. Roda-Casanova, V., Pérez-González, A., Zubizarreta-Macho, A., and Faus-Matoses, V. (2022). Influence of Cross-Section and Pitch on the Mechanical Response of NiTi Endodontic Files under Bending and Torsional Conditions—A Finite Element Analysis. J. Clin. Med., 11.10.3390/jcm11092642 ↗
6. Mechanical behavior of three nickel-titanium rotary files: A comparison of numerical simulation with bending and torsion tests10.1016/j.msec.2014.01.025 ↗
7. Comparison and analysis of ProTaper, ProTaper Next, and ProTaper Gold using finite element analysis10.4103/endo.endo_40_22 ↗
8. Evaluation of cyclic fatigue in three pediatric endodontic rotary file systems in root canals of primary molars: A finite element analysis (FEA)10.1016/j.jobcr.2025.01.023 ↗
9. Comparative evaluation of pediatric endodontic rotary file systems to bending and torsion tests: A finite element analysis10.1016/j.jobcr.2024.09.010 ↗
10. Mechanical response of nickel–titanium instruments with different cross-sectional designs during shaping of simulated curved canals10.1111/j.1365-2591.2009.01553.x ↗
11. Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis10.1111/j.1365-2591.2008.01481.x ↗
12. Validated finite element analyses of WaveOne Endodontic Instruments: A comparison between M-Wire and NiTi alloys10.1111/iej.12333 ↗
13. Faus-Matoses, V., García, R.P., Faus-Llácer, V., Faus-Matoses, I., Ezpeleta, O.A., Martínez, A.A., and Zubizarreta-Macho, A. (2022). Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph19074414 ↗
14. de Boor, C. (1978). A Practical Guide to Spline, Springer. Applied Mathematical Sciences.10.1007/978-1-4612-6333-3 ↗
15. Shewchuk, J.R. (2009). General-Dimensional Constrained Delaunay and Constrained Regular Triangulations, I: Combinatorial Properties. Twentieth Anniversary Volume: Discrete & Computational Geometry, Springer.10.1007/978-0-387-87363-3_28 ↗
16. TetGen, a Delaunay-Based Quality Tetrahedral Mesh Generator10.1145/2629697 ↗
17. Comparative Evaluation of Stress Distribution in Experimentally Designed Nickel-titanium Rotary Files with Varying Cross Sections: A Finite Element Analysis10.1016/j.joen.2017.12.013 ↗
18. Díaz-Flores García, V., Pimienta Vázquez, M.I., Tejedor, B., Suárez, A., and Freire, Y. (2024). Comparative study of torsional and bending stress in NiTi, graphene, and GUM metal endodontic files by finite element analysis. Comput. Biol. Med., 170.10.1016/j.compbiomed.2024.108017 ↗
19. (2008). Dentistry—Root-Canal Instruments—Part 1: General Requirements and Test Methods (Standard No. ISO 3630-1:2008).
20. Algebraic mesh quality metrics for unstructured initial meshes10.1016/S0168-874X(02)00070-7 ↗
21. A three-dimensional model describing stress-induced solid phase transformation with permanent inelasticity10.1016/j.ijplas.2006.02.012 ↗
22. Orhan, K. (2020). Applications of Micro-CT Technology in Endodontics. Micro-Computed Tomography (Micro-CT) in Medicine and Engineering, Springer International Publishing.10.1007/978-3-030-16641-0 ↗
23. Faus-Matoses, V., Faus-Llacer, V., Aldeguer Muñoz, A., Alonso Perez-Barquero, J., Faus-Matoses, I., Ruiz-Sanchez, C., and Zubizarreta-Macho, A. (2022). A Novel Digital Technique to Analyze the Wear of CM-Wire NiTi Alloy Endodontic Reciprocating Files: An In Vitro Study. Int. J. Environ. Res. Public Health, 19.10.3390/ijerph19063203 ↗
24. Carpegna, G. (2021). Mechanical Behaviours of NiTi Rotary Instruments Using Micro-CT and Finite Element Analysis. [Ph.D. Thesis, Politecnico di Torino].
25. Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture10.1016/j.joen.2010.02.010 ↗
26. The geometric effect of an off-centered cross-section on nickel–titanium rotary instruments: A finite element analysis study10.1016/j.jds.2016.11.005 ↗
27. Adaptive tetrahedral Mesh generation by constrained Delaunay refinement10.1002/nme.2318 ↗
28. Shewchuk, J.R., and Si, H. (2014, January 8–11). Higher-quality tetrahedral mesh generation for domains with small angles by constrained Delaunay refinement. Proceedings of the Thirtieth Annual Symposium on Computational Geometry, Kyoto, Japan.10.1145/2582112.2582138 ↗
29. Effect of Pitch Length on the Behavior of Rotary Triple Helix Root Canal Instruments10.1097/01.DON.0000125877.26495.69 ↗
30. Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal
31. Effects of Conservative Access and Apical Enlargement on Shaping and Dentin Preservation with Traditional and Modern Instruments: A Micro-computed Tomographic Study10.1016/j.joen.2023.01.004 ↗
32. Comparative evaluation of pericervical dentin preservation and fracture resistance of root canal-treated teeth with rotary endodontic file systems of different types of taper—An in vitro study
33. Effect of Apical Size and Taper on the Efficacy of Root Canal Disinfection with LED Photodynamic Therapy as an Adjunct to Irrigation with Sodium Hypochlorite10.34172/jlms.2021.58 ↗
34. Comparative evaluation of dentinal microcrack formation in the apical region of permanent teeth after root canal preparation with ProTaper Next and TruNatomy rotary file system—An SEM study10.4103/endo.endo_182_21 ↗
35. Longitudinal craze line propagation in human root dentin after instrumentation with NiTi rotary files of different instrument tapers after long-term chewing simulation10.1007/s00784-021-04238-3 ↗