Eddy Current Distribution in Magnetotherapy of Bones: A Qualitative and Quantitative Study
Source abstract
Abstract
Unlike pharmacological and surgical methods, electrical and especially magnetic stimulation are of interest due to their noninvasiveness and high tolerability by patients. Ensuring the repeatability of procedures and achieving the highest possible homogeneity of the eddy current distribution appears to be crucial, particularly in the context of potential clinical trials. This highlights the qualitative aspect of the therapy. Equally important, however, are the outcomes in terms of eddy current generation and their presentation in a psychological context, particularly in relation to patient communication. Many patients undergoing treatment express a desire to understand how the applicator works, what the procedure does to their body, and what sensations or effects are occurring in their limbs during therapy. On the other hand, quantitative analysis enables the rescaling of the magnetic field induced within the applicator, which in turn allows for determining the appropriate level of induced currents in the limb of a specific patient.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electromagnetic Fields and Biological Effects · Muscle activation and electromyography studies · Body Composition Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical and Power Engineering, Faculty of Electrical Engineering, Automatics, Computer Science and Biomedical Engineering, AGH University of Krakow, 30-059 Krakow, Poland
Department of Automation and Robotics, Polytechnic Faculty, University of Applied Sciences in Tarnow, 33-100 Tarnow, Poland
References (43)
Show source-provided references
1. Comparative Analysis of the Extremely Low-Frequency Magnetic Field Exposure from Overhead Power Lines10.30638/eemj.2013.141 ↗
2. Essential Facts on the History of Hyperthermia and their Connections with Electromedicine
3. Marchewka, R., Trzmiel, T., and Hojan, K. (2025). Effect of Low-Frequency Magnetic Field Stimulation on Physical Performance and Inflammation in Post-Stroke Patients: A Feasibility and Safety Study. Appl. Sci., 15.10.3390/app15063182 ↗
4. Mechanotransduction and Functional Response of the Skeleton to Physical Stress: The Mechanisms and Mechanics of Bone Adaptation10.1007/s007760050064 ↗
5. Simulation of the Effects of Electric and Magnetic Loadings on Internal Bone Remodeling10.1007/978-3-642-21729-6_116 ↗
6. A predictive mechanical model for evaluating vertebral fracture probability in lumbar spine under different osteoporotic drug therapies10.1016/j.cmpb.2016.04.006 ↗
7. Image Texture in Dental Panoramic Radiographs as a Potential Biomarker of Osteoporosis10.1109/TBME.2013.2256908 ↗
8. Changes in Electrical Properties of Bones as a Diagnostic Tool for Measurement of Fracture Healing10.13172/2050-2303-2-1-316 ↗
9. Jayanand, S., and Behari, J. (2008, January 21–24). Effect of Electrical Stimulation in Mineralization and Collagen Enrichment of Osteoporotic Rat Bones. Proceedings of the International Conference on Microwave, Jaipur, India.10.1109/AMTA.2008.4763231 ↗
10. The Preventive Effect on Bone Loss of 50-Hz, 1-mT Electromagnetic Field in Ovariectomized Rats10.1007/s007740200050 ↗
11. Numerical Analysis of Eddy Current Distribution in Submental Region Induced by Magnetic Stimulation for Treating Dysphagia10.1109/TNSRE.2020.2981399 ↗
12. Sandurkov, B., Rapp, J., Hemmert, W., and Gleich, B. (2023). Low Energy Magnetic Stimulation of the Phrenic Nerve-A Simulation Study. Biomed. Phys. Eng. Express, 9.10.1088/2057-1976/ace7d7 ↗
13. Enhancement of Bone Consolidation Using High-Frequency Pulsed Electromagnetic Fields (HF-PEMFs): An Experimental Study on Rats
14. The Effects and Mechanisms of Electromagnetic Fields on Bone Remodeling: From Clinical to Laboratory
15. Pulsed Electromagnetic Field May Accelerate In Vitro Endochondral Ossification10.1002/bem.21882 ↗
16. Do Magnetic Field Applications Lead to Improved Bone Union in Light of Evidence-Based Medicine Principles? Analysis of the Scientific Evidence from Basic Science to Clinical Research10.5114/phr.2023.133715 ↗
17. Electromagnetic Stimulation as Coadjuvant in the Healing of Diaphyseal Femoral Fractures: A Randomized Controlled Trial10.25100/cm.v45i2.1479 ↗
18. Visualization of Magnetic Field Generated by Portable Coil Designed for Magnetotherapy
19. Healing of Orthopaedic Diseases by Means of Electromagnetic Field
20. Bottauscio, O., Arduino, A., Chiampi, M., and Zilberti, L. (2023). Simplified Modeling of Implanted Medical Devices with Metallic Filamentary Closed Loops Exposed to Low or Medium Frequency Magnetic Fields. Comput. Methods Programs Biomed., 229.10.1016/j.cmpb.2022.107316 ↗
21. Syrek, P., and Barbulescu, R. (2017, January 23–25). Parametric Curves to Trace the TMS Coils Windings. Proceedings of the 10th International Symposium on Advanced Topics in Electrical Engineering (ATEE), Bucharest, Romania.10.1109/ATEE.2017.7905069 ↗
22. Realistic Electric Field Characterization of Clinically Used Deformable Large TMS Coils in a Large Cohort10.1016/j.brs.2025.05.136 ↗
23. Berger, T.A., Mantell, K., Haigh, Z., Perera, N., Alekseichuk, I., and Opitz, A. (2025). Comprehensive Evaluation of U-Net-Based Transcranial Magnetic Stimulation Electric Field Estimations. Sci. Rep., 15.10.1038/s41598-025-95767-4 ↗
24. Optimizing A Deep Learning Model for the Prediction of Electric Field Induced by Transcranial Magnetic Stimulation for Mild to Moderate Traumatic Brain Injury Patients10.1063/9.0000640 ↗
25. The Virtual Family—Development of surface-based anatomical models of two adults and two children for dosimetric simulations10.1088/0031-9155/55/2/N01 ↗
26. Fang, Q., and Boas, D. (July, January 28). Tetrahedral mesh generation from volumetric binary and gray-scale images. Proceedings of the IEEE International Symposium on Biomedical Imaging, Boston, MA, USA.
27. Uncertainty problem as illustrated by magnetotherapy
28. Experiments with models of variability for biological tissues
29. The dielectric properties of biological tissues: III Parametric models of the dielectric spectrum of tissues10.1088/0031-9155/41/11/003 ↗
30. Non-destructive testing of conductive material by eddy current air probe based on swept frequency10.2478/jee-2015-0028 ↗
31. A Simple Absolute Estimate of Peak Eddy Currents Induced by Transcranial Magnetic Stimulation Using the GR Model10.1109/TMAG.2013.2250512 ↗
32. Diao, Y., Joseph, W., Poljak, D., Giaccone, L., Kodera, S., Laakso, I., Yamazaki, K., Li, K., Sasaki, K., and Tanghe, E. (2025). Recent Advances and Future Perspective in Computational Bioelectromagnetics for Exposure Assessments. Bioelectromagnetics, 46.10.1002/bem.70002 ↗
33. Cvetković, M., and Totić, A. (2024, January 25–28). Magnetotherapy Modeling Using a Simplified and Anatomical Human Body Models. Proceedings of the SpliTech2024, SpliTech, Split, Croatia.10.23919/SpliTech61897.2024.10612679 ↗
34. Cvetković, M., and Sučić, B. (2024). Analysis of Magnetotherapy Device-Induced Fields Using Cylindrical Human BodyModel. Electronics, 13.10.3390/electronics13050849 ↗
35. Yang, S., Xu, G., Wang, L., and Zhang, X. (2008, January 20–25). Effect of the different winding methods of coil on electromagnetic field during transcranial magnetic stimulation. Proceedings of the 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, BC, Canada.
36. Focused Magnetic Resonance Coupling Coils for Electromagnetic Therapy Applications10.1109/TBME.2015.2408432 ↗
37. Plonecki, P., Starzynski, P., Wincenciak, S., and Sawicki, B. (2009, January 22–24). Modelling of eddy-currents using electric scalar potential. Proceedings of the XV ISTET International Symposium on Theoretical Engineering, Lübeck, Germany.
38. IT’IS Foundation (2025, August 21). Tissue Properties Database V5.0: Density (kg/m3) Data for Human Tissues. Available online: https://itis.swiss/virtual-population/tissue-properties/database/density/.
39. International Commission on Non-Ionizing Radiation Protection (ICNIRP) (2020). Guidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz). Health Phys., 118, 483–524.10.1097/HP.0000000000001210 ↗
40. International Commission on Non-Ionizing Radiation Protection (ICNIRP) (2010). Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1 Hz to 100 kHz). Health Phys., 99, 818–836.10.1097/HP.0b013e3181f06c86 ↗
41. Integration of LSTM and U-Net Models for Monitoring Electrical Absorption with a System of Sensors and Electronic Circuits
42. A new direction for ultrasound therapy in sports medicine10.2165/00007256-200333020-00002 ↗
43. Barnes, F.S., and Greenebaum, B. (2006). Mechanisms and therapeutic applications of time-varying and static magnetic fields. Biological and Medical Aspects of Electromagnetic Fields, CRC Press. [3rd ed.].