Abstract

Spectral-domain Optical Coherence Tomography (SD-OCT) is a critical tool in ophthalmology, providing high-resolution cross-sectional images of the retina. Accurate segmentation of sub-retinal layers is essential for diagnosing and monitoring retinal diseases. While manual segmentation by clinicians is the gold standard, it is subjective, time-intensive, and impractical for large-scale use. This study introduces an automated segmentation algorithm based on graph theory, utilizing a shortest-path graph-search technique to delineate seven intra-retinal boundaries. The algorithm incorporates a region of interest (ROI) selection to enhance efficiency, achieving a mean computation time of 0.93 s on standard systems suitable for real-time clinical applications. Image denoising was evaluated using Gaussian and wavelet-based filters. While wavelet-based denoising improved accuracy to some extent, its increased computation time (~10 s/image) was the trade-off. The intra-retinal layer thicknesses computed by the segmentation algorithm was consistent with previous studies and demonstrated high accuracy with respect to manual segmentation, thus indicating clinical relevance. Future research will explore integrating machine learning to improve robustness across diverse retinal pathologies, enhancing the algorithm’s applicability in clinical settings.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Retinal Imaging and Analysis · Optical Coherence Tomography Applications · Retinal Diseases and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA

School of Optometry and Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada

Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada

Department of Psychology, University of Nevada, Reno, NV 89557, USA

Funding

NSERC Discovery Grant

References (31)

Show source-provided references
1. Optical Coherence Tomography—Principles and Applications10.1088/0034-4885/66/2/204 ↗
2. Segmentation of Choroidal Boundary in Enhanced Depth Imaging OCTs Using a Multiresolution Texture Based Modeling in Graph Cuts10.1155/2014/479268 ↗
3. Optical Coherence Tomography HHS Public Access10.1126/science.1957169 ↗
4. Optical Coherence Tomography of the Human Retina10.1001/archopht.1995.01100030081025 ↗
5. Spectral Domain Optical Coherence Tomography for Glaucoma (an AOS Thesis)
6. Automated 3-D Retinal Layer Segmentation of Macular Optical Coherence Tomography Images with Serous Pigment Epithelial Detachments10.1109/TMI.2014.2359980 ↗
7. Fully Automated Detection of Diabetic Macular Edema and Dry Age-Related Macular Degeneration from Optical Coherence Tomography Images10.1364/BOE.5.003568 ↗
8. Automatic Segmentation of Seven Retinal Layers in SDOCT Images Congruent with Expert Manual Segmentation10.1364/OE.18.019413 ↗
9. Automatic segmentation of up to ten layer boundaries in SD-OCT images of the mouse retina with and without missing layers due to pathology10.1364/BOE.5.000348 ↗
10. Tian, J., Varga, B., Somfai, G.M., Lee, W.-H., Smiddy, W.E., and DeBuc, D.C. (2015). Real-Time Automatic Segmentation of Optical Coherence Tomography Volume Data of the Macular Region. PLoS ONE, 10.10.1371/journal.pone.0133908 ↗
11. Ho, P.-G. (2011). A Review of Algorithms for Segmentation of Retinal Image Data Using Optical Coherence Tomography. Image Segmentation, Intech Publishers.10.5772/628 ↗
12. Roy, P., Lakshminarayanan, V., Parthasarathy, M.K., Zelek, J.S., and Gholami, P. (2018, January 29–31). Automated Intraretinal Layer Segmentation of Optical Coherence Tomography Images Using Graph-Theoretical Methods. Proceedings of the Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XXII, San Francisco, CA, USA.10.1117/12.2282949 ↗
13. Roy, P. (2018). Automated Segmentation of Retinal Optical Coherence Tomography Images. [Master’s Thesis, University of Waterloo].
14. A Simple Algorithm for Image Denoising Based on MS Segmentation
15. Intra-Retinal Layer Segmentation in Optical Coherence Tomography Images10.1364/OE.17.023719 ↗
16. Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography Images10.1109/TMI.2009.2016958 ↗
17. A Review of Algorithms for Segmentation of Optical Coherence Tomography from Retina10.4103/2228-7477.114321 ↗
18. Image Denoising Based On Gaussian/Bilateral Filter and Its Method Noise Thresholding10.1007/s11760-012-0372-7 ↗
19. Roy, P., Parthasarathy, M.K., Zelek, J., and Lakshminarayanan, V. (2018, January 11–13). Comparison of Gaussian Filter Versus Wavelet-Based Denoising on Graph-Based Segmentation of Retinal OCT Images. Proceedings of the Biomedical Applications in Molecular, Structural, and Functional Imaging, Houston, TX, USA.10.1117/12.2292479 ↗
20. Teng, P. (2017, December 29). Caserel—An Open Source Software for Computer-Aided Segmentation of Retinal Layers in Optical Coherence Tomography Images. Available online: https://github.com/pangyuteng/caserel.
21. Efficient Graph-Based Image Segmentation10.1023/B:VISI.0000022288.19776.77 ↗
22. Three-Dimensional Segmentation of Fluid-Associated Abnormalities in Retinal OCT: Probability Constrained Graph-Search-Graph-Cut10.1109/TMI.2012.2191302 ↗
23. Graph-Based Multi-Surface Segmentation of OCT Data Using Trained Hard and Soft Constraints10.1109/TMI.2012.2225152 ↗
24. Optimal Surface Segmentation in Volumetric Images—A Graph-Theoretic Approach10.1109/TPAMI.2006.19 ↗
25. Graph Based Image Segmentation
26. Thickness Mapping of Eleven Retinal Layers Segmented Using the Diffusion Maps Method in Normal Eyes10.1155/2015/259123 ↗
27. Agrawal, P., and Karule, P.T. (2014, January 6–8). Measurement of retinal thickness for detection of Glaucoma. Proceedings of the 2014 International Conference on Green Computing Communication and Electrical Engineering (ICGCCEE), Coimbatore, India.10.1109/ICGCCEE.2014.6922263 ↗
28. Normal Macular Thickness Measurements in Healthy Eyes Using Stratus Optical Coherence Tomography10.1001/archopht.124.2.193 ↗
29. Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation
30. Retinal Thickness Measurements from Optical Coherence Tomography Using a Markov Boundary Model10.1109/42.952728 ↗
31. OCTID: Optical Coherence Tomography Image Database10.1016/j.compeleceng.2019.106532 ↗