journal article·2025-07-23Open access

Deep Learning-Powered Super Resolution Reconstruction Improves 2D T2-Weighted Turbo Spin Echo MRI of the Hippocampus

Elisabeth Sartoretti, Thomas Sartoretti, Alex Alfieri, Tobias Hoh, Alexander Maurer, Manoj Mannil, Christoph A. Binkert, Sabine Sartoretti-Schefer

Applied Sciences· Volume 15· Issue 15

Abstract

Purpose: To assess the performance of 2D T2-weighted (w) Turbo Spin Echo (TSE) MRI reconstructed with a deep learning (DL)-powered super resolution reconstruction (SRR) algorithm combining compressed sensing (CS) denoising and resolution upscaling for high-resolution hippocampal imaging in patients with (epileptic) seizures and suspected hippocampal pathology. Methods: A 2D T2w TSE coronal hippocampal sequence with compressed sense (CS) factor 1 (scan time 270 s) and a CS-accelerated sequence with a CS factor of 3 (scan time 103 s) were acquired in 28 patients. Reconstructions using the SRR algorithm (CS 1-SSR-s and CS 3-SSR-s) were additionally obtained in real time. Two readers graded the images twice, based on several metrics (image quality; artifacts; visualization of anatomical details of the internal hippocampal architecture (HIA); visibility of dentate gyrus/pes hippocampi/fornix/mammillary bodies; delineation of gray and white matter). Results: Inter-readout agreement was almost perfect (Krippendorff’s alpha coefficient = 0.933). Compared to the CS 1 sequence, the CS 3 sequence significantly underperformed in all 11 metrics (p < 0.001-p = 0.04), while the CS 1-SRR-s sequence outperformed in terms of overall image quality and visualization of the left HIA and right pes hippocampi (p < 0.001-p < 0.04) but underperformed in terms of presence of artifacts (p < 0.01). Lastly, relative to the CS 1 sequence, the CS 3-SRR-s sequence was graded worse in terms of presence of artifacts (p < 0.003) but with improved visualization of the right pes hippocampi (p = 0.02). Conclusion: DL-powered SSR demonstrates its capacity to enhance imaging performance by introducing flexibility in T2w hippocampal imaging; it either improves image quality for non-accelerated imaging or preserves acceptable quality in accelerated imaging, with the additional benefit of a reduced scan time.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · Advanced Neuroimaging Techniques and Applications · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Radiology, Kantonsspital Winterthur, Brauerstrasse 15, 8401 Winterthur, Switzerland

Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland

Department of Neurosurgery, Kantonsspital Winterthur, 8400 Winterthur, Switzerland

Philips Healthsystems, 8302 Zurich, Switzerland

Department of Nuclear Medicine, University Hospital Zurich, 8091 Zurich, Switzerland

Institute of Diagnostic and Interventional Radiology, Caritas Krankenhaus Bad Mergentheim, 97980 Bad Mergentheim, Germany

References (36)

Show source-provided references
1. Predictive value of hippocampal internal architecture asymmetry in temporal lobe epilepsy10.1016/j.eplepsyres.2013.05.008 ↗
2. Optimizing the diagnosis of hippocampal sclerosis using MR imaging
3. Evaluating hippocampal internal architecture on MRI: Inter-rater reliability of a proposed scoring system10.1016/j.eplepsyres.2013.05.009 ↗
4. High-resolution 7T MRI of the human hippocampus in vivo10.1002/jmri.21576 ↗
5. Ver Hoef, L., Deshpande, H., Cure, J., Selladurai, G., Beattie, J., Kennedy, R.E., Knowlton, R.C., and Szaflarski, J.P. (2021). Clear and Consistent Imaging of Hippocampal Internal Architecture With High Resolution Multiple Image Co-registration and Averaging (HR-MICRA). Front. Neurosci., 15.10.3389/fnins.2021.546312 ↗
6. Imaging Aspects of the Hippocampus10.1148/rg.210153 ↗
7. Sparse MRI: The application of compressed sensing for rapid MR imaging10.1002/mrm.21391 ↗
8. Sartoretti, E., Sartoretti, T., Binkert, C., Najafi, A., Schwenk, Á., Hinnen, M., van Smoorenburg, L., Eichenberger, B., and Sartoretti-Schefer, S. (2019). Reduction of procedure times in routine clinical practice with Compressed SENSE magnetic resonance imaging technique. PLoS ONE, 14.10.1371/journal.pone.0214887 ↗
9. fastMRI: A Publicly Available Raw k-Space and DICOM Dataset of Knee Images for Accelerated MR Image Reconstruction Using Machine Learning10.1148/ryai.2020190007 ↗
10. Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T10.1016/j.ejrad.2022.110562 ↗
11. Scan-specific robust artificial-neural-networks for k-space interpolation (RAKI) reconstruction: Database-free deep learning for fast imaging10.1002/mrm.27420 ↗
12. Deep Learning Super-Resolution Reconstruction for Fast and Motion-Robust T2-weighted Prostate MRI10.1148/radiol.230427 ↗
13. An Adaptive Intelligence Algorithm for Undersampled Knee MRI Reconstruction10.1109/ACCESS.2020.3034287 ↗
14. Pezzotti, N., de Weerdt, E., Yousefi, S., Elmahdy, M.S., van Gemert, J., Schülke, C., Doneva, M., Nielsen, T., Kastryulin, S., and Lelieveldt, B.P.F. (2019). Adaptive-CS-Net: FastMRI with Adaptive Intelligence. arXiv.
15. Deep learning–based acceleration of Compressed Sense MR imaging of the ankle10.1007/s00330-022-08919-9 ↗
16. Rapid 3D breath-hold MR cholangiopancreatography using deep learning–constrained compressed sensing reconstruction10.1007/s00330-022-09227-y ↗
17. Harder, F.N., Weiss, K., Amiel, T., Peeters, J.M., Tauber, R., Ziegelmayer, S., Burian, E., Makowski, M.R., Sauter, A.P., and Gschwend, J.E. (2022). Prospectively Accelerated T2-Weighted Imaging of the Prostate by Combining Compressed SENSE and Deep Learning in Patients with Histologically Proven Prostate Cancer. Cancers, 14.10.3390/cancers14235741 ↗
18. Deep learning constrained compressed sensing reconstruction improves high-resolution three-dimensional (3D) T2-weighted turbo spin echo magnetic resonance imaging (MRI) of the lumbar spine10.1016/j.crad.2024.09.004 ↗
19. Super-resolution musculoskeletal MRI using deep learning10.1002/mrm.27178 ↗
20. Image Super-Resolution Using Deep Convolutional Networks10.1109/TPAMI.2015.2439281 ↗
21. A Review of the Deep Learning Methods for Medical Images Super Resolution Problems10.1016/j.irbm.2020.08.004 ↗
22. Deep learning super-resolution reconstruction for fast and high-quality cine cardiovascular magnetic resonance10.1007/s00330-024-11145-0 ↗
23. Five-minute knee MRI: An AI-based super resolution reconstruction approach for compressed sensing. A validation study on healthy volunteers10.1016/j.ejrad.2024.111418 ↗
24. Deep-learning-based reconstruction of T2-weighted magnetic resonance imaging of the prostate accelerated by compressed sensing provides improved image quality at half the acquisition time10.21037/qims-23-1488 ↗
25. Accelerated High-resolution T1- and T2-weighted Breast MRI with Deep Learning Super-resolution Reconstruction10.1016/j.acra.2024.12.055 ↗
26. Hahnfeldt, R., Terzis, R., Dratsch, T., Basten, L.M., Rauen, P., Oppermann, J., Grevenstein, D., Janßen, J.P., Zeid, N.E.-H.A., and Sonnabend, K. (2025). Is a 3-Minute Knee MRI Protocol Sufficient for Daily Clinical Practice? A SuperResolution Reconstruction Approach Using AI and Compressed Sensing. Diagnostics, 15.10.3390/diagnostics15101206 ↗
27. Aziz-Safaie, T., Bischoff, L.M., Katemann, C., Peeters, J.M., Kravchenko, D., Mesropyan, N., Beissel, L.D., Dell, T., Weber, O.M., and Pieper, C.C. (2025). Fast and Robust Single-Shot Cine Cardiac MRI Using Deep Learning Super-Resolution Reconstruction. Investig. Radiol., published ahead of print.10.1097/RLI.0000000000001186 ↗
28. Histologically Confirmed Hippocampal Structural Features Revealed by 3T MR Imaging: Potential to Increase Diagnostic Specificity of Mesial Temporal Sclerosis10.3174/ajnr.A2154 ↗
29. Measurement of hippocampal subfields and age-related changes with high resolution MRI at 4T10.1016/j.neurobiolaging.2006.03.007 ↗
30. A high-resolution computational atlas of the human hippocampus from postmortem magnetic resonance imaging at 9.4 T10.1016/j.neuroimage.2008.08.042 ↗
31. Improving Diagnostic Performance of MRI for Temporal Lobe Epilepsy with Deep Learning-Based Image Reconstruction in Patients with Suspected Focal Epilepsy10.3348/kjr.2023.0842 ↗
32. A harmonized segmentation protocol for hippocampal and parahippocampal subregions: Why do we need one and what are the key goals?: A Harmonized Hippocampal Subfield Protocol: Key Goals and Impact10.1002/hipo.22671 ↗
33. Peixoto-Santos, J.E., Carvalho, L.E.D.D., Kandratavicius, L., Diniz, P.R.B., Scandiuzzi, R.C., Coras, R., Blümcke, I., Assirati, J.A., Carlotti, C.G., and Matias, C.C.M.S. (2018). Manual Hippocampal Subfield Segmentation Using High-Field MRI: Impact of Different Subfields in Hippocampal Volume Loss of Temporal Lobe Epilepsy Patients. Front. Neurol., 9.10.3389/fneur.2018.00927 ↗
34. The hippocampus: Normal anatomy and pathology10.2214/ajr.171.4.9763010 ↗
35. Visualization of the amygdalo–hippocampal border and its structural variability by 7T and 3T magnetic resonance imaging10.1002/hbm.22477 ↗
36. Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences10.1007/s00256-016-2490-8 ↗