Iterative Finite Element Analysis of Buccolingual Width on Canine Distal Movement in Clear Aligner Treatment
Source abstract
Abstract
This study investigated the biomechanical effects of varying buccolingual beam widths in maxillary first premolar extraction spaces on canine distal bodily movement during clear aligner treatment. Using finite element analysis, four distinct models were constructed, incorporating beam designs with widths of 0 (edentulous), 1, 2, and 3 mm within the extraction space. Each model underwent a comprehensive 50-stage iterative simulation to evaluate canine displacement patterns, tipping, rotational movements, aligner deformation characteristics, and magnitudes of forces and moments applied to the canines throughout long-term tooth movement. Group 0 (no beam, 0 mm beam width) exhibited the greatest crown displacement and tipping angle. In contrast, Group 2 (2 mm beam width) most effectively reduced the final angulation of the canine, whereas Group 3 (3 mm beam width) was most effective in controlling unwanted rotation and minimizing deformation of the clear aligner. Furthermore, an increase in the beam width was associated with a trend of higher initial force and lower initial moment. Notably, relatively high levels of both force and moment were maintained during the later stages of the simulation, which is advantageous for sustained control of tooth movement. In conclusion, incorporating a beam of 2–3 mm width into the maxillary first premolar extraction space appears to be optimal for managing canine tipping and rotation while promoting bodily movement of the tooth.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · dental development and anomalies · Temporomandibular Joint Disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthodontics, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
Funding
National Research Foundation for Korea (NRF)
References (39)
Show source-provided references
1. The effects of aligner overtreatment on torque control and intrusion of incisors for anterior retraction with clear aligners a finite-element study10.1016/j.ajodo.2021.02.020 ↗
2. Evaluation of the effect of attachments on torque control of palatally positioned maxillary lateral teeth with clear aligners: Finite element analysis10.4041/kjod24.029 ↗
3. Cheng, Y., Liu, X., Chen, X., Li, X., Fang, S., Wang, W., Ma, Y., and Jin, Z. (2022). The three-dimensional displacement tendency of teeth depending on incisor torque compensation with clear aligners of different thicknesses in cases of extraction: A finite element study. BMC Oral Health, 22.10.1186/s12903-022-02521-7 ↗
4. Meng, X., Wang, C., Xu, W., Wang, R., Zheng, L., Wang, C., Aversa, R., and Fan, Y. (2023). Effects of different designs of orthodontic clear aligners on the maxillary central incisors in the tooth extraction cases: A biomechanical study. BMC Oral Health, 23.10.1186/s12903-023-03106-8 ↗
5. Preparation and characterization of thermoplastic materials for invisible orthodontics10.4012/dmj.2011-120 ↗
6. Effect of attachment type on distal bodily movement of the maxillary canine in aligner orthodontics: A finite element study10.2319/120121-879.1 ↗
7. Li, Q., Xu, B., Fang, D., and Yang, K. (2025). Impacts of surface wear of attachments on maxillary canine distalization with clear aligners: A three-dimensional finite element study. Front. Bioeng. Biotechnol., 13.10.3389/fbioe.2025.1530133 ↗
8. Finite element analysis of the biomechanical effect of clear aligners in extraction space closure under different anchorage controls10.1016/j.ajodo.2022.02.018 ↗
9. Qiang, R., Wu, J., Gao, J., Chen, H., Xu, J., Jin, Z., and Ma, Y. (2025). An integrated approach to posterior anchorage preparation and incisor torque compensation in premolar extraction cases using clear aligners. BMC Oral Health, 25.10.1186/s12903-025-05945-z ↗
10. The effects of aligner anchorage preparation on mandibular first molars during premolar-extraction space closure with clear aligners: A finite element study10.1016/j.ajodo.2022.12.013 ↗
11. The effect of enhanced structure in the posterior segment of clear aligners during anterior retraction: A three dimensional finite element and experimental model analysis10.1186/s40510-023-00502-2 ↗
12. Biomechanical effects of clear aligners with different thicknesses and gingival-margin morphology for appliance design optimization10.1016/j.ajodo.2022.12.014 ↗
13. Effect of trimming line design and edge extension of orthodontic aligners on force transmission: An in vitro study10.1016/j.jdent.2022.104276 ↗
14. Forces and moments generated by 3D direct printed clear aligners of varying labial and lingual thicknesses during lingual movement of maxillary central incisor: An in vitro study10.1186/s40510-023-00475-2 ↗
15. A finite element analysis of the effects of semipontic design on tooth movement during mesialization of the mandibular second molar with clear aligners10.1016/j.ajodo.2024.07.007 ↗
16. Effects of clear aligner edentulous space design on distal canine movement: An iterative finite element analysis in cases involving extraction10.4041/kjod24.286 ↗
17. Biomechanical effects of clear aligner with different shape design at extraction space area during anterior teeth retraction10.1111/ocr.12795 ↗
18. The effect of space arrangement between anterior teeth on their retraction with clear aligners in first premolar extraction treatment: A finite element study10.1186/s40510-023-00484-1 ↗
19. Effects of Attachment of Plastic Aligner in Closing of Diastema of Maxillary Dentition by Finite Element Method10.1155/2019/1075097 ↗
20. A finite element analysis of the effects of archwire size on orthodontic tooth movement in extraction space closure with miniscrew sliding mechanics10.1186/s40510-018-0255-8 ↗
21. Comparative Assessment of Clinical and Predicted Treatment Outcomes of Clear Aligner Treatment: An in Vivo Study10.5152/TurkJOrthod.2019.19019 ↗
22. The treatment effects of Invisalign orthodontic aligners: A systematic review10.14219/jada.archive.2005.0117 ↗
23. Efficacy of clear aligners in controlling orthodontic tooth movement: A systematic review10.2319/061614-436.1 ↗
24. Rossini, G., Schiaffino, M., Parrini, S., Sedran, A., Deregibus, A., and Castroflorio, T. (2020). Upper Second Molar Distalization with Clear Aligners: A Finite Element Study. Appl. Sci., 10.10.3390/app10217739 ↗
25. Maxillary molar distalization with aligners in adult patients: A multicenter retrospective study10.1186/s40510-016-0126-0 ↗
26. Effectiveness of composite attachments in controlling upper-molar movement with aligners
27. Three-dimensional orthodontic force measurements10.1016/j.ajodo.2009.02.025 ↗
28. Effects of time and clear aligner removal frequency on the force delivered by different polyethylene terephthalate glycol-modified materials determined with thin-film pressure sensors10.1016/j.ajodo.2018.03.017 ↗
29. Hahn, W., Dathe, H., Fialka-Fricke, J., Fricke-Zech, S., Zapf, A., Kubeen-Meesenburg, D., and Sadat-Khonsari, R. (2009). Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping. Am. J. Orthod. Dentofac. Orthop., 136.10.1016/j.ajodo.2008.12.015 ↗
30. Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor10.2319/033009-181.1 ↗
31. Initial forces generated by three types of thermoplastic appliances on an upper central incisor during tipping10.1093/ejo/cjp047 ↗
32. Force delivery properties of thermoplastic orthodontic materials10.1016/j.ajodo.2006.03.034 ↗
33. In Vitro Comparison of Direct Attachment Shape and Size on the Orthodontic Forces and Moments Generated by Thermoplastic Aligners During Expansion10.1111/ocr.12865 ↗
34. Proffit, W.R. (2018). Contemporary Orthodontics, Elsevier. [6th ed.].
35. A Biomechanical Case Study on the Optimal Orthodontic Force on the Maxillary Canine Tooth Based on Finite Element Analysis10.1631/jzus.B1700195 ↗
36. Optimal Force Magnitude for Bodily Orthodontic Tooth Movement With Fixed Appliances: A Systematic Review10.1016/j.ajodo.2019.05.011 ↗
37. Using digital image correlation to measure displacement and strain during involving distal movement of anterior teeth with clear aligner10.4012/dmj.2022-255 ↗
38. Kim, W.H., Hong, K., Lim, D., Lee, J.H., Jung, Y.J., and Kim, B. (2020). Optimal Position of Attachment for Removable Thermoplastic Aligner on the Lower Canine Using Finite Element Analysis. Materials, 13.10.3390/ma13153369 ↗