journal article·2025-06-20Open access

Study on Molybdenum–Rhenium Alloy Ultrasonic Resonance Temperature Sensor

Haijian Liang, Gao Wang, Xiaomei Yang, Yanlong Wei, Hongxin Xue

Applied Sciences· Volume 15· Issue 13

Abstract

Compared to traditional temperature measurement methods, ultrasonic temperature measurement technology based on the principle of resonance offers advantages such as shorter section lengths, higher signal amplitude, and reduced signal attenuation. First, the type of sensor-sensitive element was determined, with a resonant design chosen to improve measurement performance; using magnetostrictive and resonant temperature measurement principles, the length, diameter, and resonator dimensions of the waveguide rod were designed, and a molybdenum–rhenium alloy (Mo-5%Re) material suitable for high-temperature environments was selected; COMSOL finite element simulation was used to simulate the propagation characteristics of acoustic signals in the waveguide rod, observing the distribution of sound pressure and energy attenuation, verifying the applicability of the model in high-temperature testing environments. Second, a resonant temperature sensor consistent with the simulation parameters was prepared using a molybdenum–rhenium alloy waveguide rod, and an ultrasonic resonant temperature-sensing system suitable for high-temperature environments up to 1800 °C was constructed using the molybdenum–rhenium alloy waveguide rod. The experiment used a tungsten–rhenium calibration furnace to perform static calibration of the sensor. The temperature range was set from room temperature to 1800 °C, with the temperature increased by 100 °C at a time, and it was maintained at each temperature point for 5 to 10 min to ensure thermal stability. This was conducted to verify the performance of the sensor and obtain the functional relationship between temperature and resonance frequency. Experimental results show that during the heating process, the average resonance frequency of the sensor decreased from 341.8 kHz to 310.37 kHz, with an average sensitivity of 17.66 Hz/°C. During the cooling process, the frequency increased from 309 kHz to 341.8 kHz, with an average sensitivity of 18.43 Hz/°C. After cooling to room temperature, the sensor’s resonant frequency returned to its initial value of 341.8 kHz, demonstrating excellent repeatability and thermal stability. This provides a reliable technical foundation for its application in actual high-temperature environments.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Flow Measurement and Analysis · Advanced Sensor Technologies Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Software, North University of China, Taiyuan 030051, China

Science and Technology on Electronic Test & Measurement Laboratory, North University of China, Taiyuan 030051, China

Science and Technology on Sensor Test & Intelligent Information Processing Laboratory, Department of Computer Science, Taiyuan Normal University, Taiyuan 030619, China

School of Computer Science and Technology, North University of China, Taiyuan 030051, China

Funding

National Natural Science Foundation of China · Aeronautical Science Foundation of China · Fundamental Research Program of Shanxi Province

References (33)

Show source-provided references
1. Real-time estimation of thermal boundary conditions and internal temperature fields for thermal protection system of aerospace vehicle via temperature sequence10.1016/j.icheatmasstransfer.2023.106618 ↗
2. Zhang, B., Wei, Y.-J., Liu, W.-Y., Zhang, Y.-J., Yao, Z., Zhao, L.-H., and Xiong, J.-J. (2017). A liquid level measurement technique outside a sealed metal container based on ultrasonic impedance and echo energy. Sensors, 17.10.3390/s17010185 ↗
3. Calibration of a plug-type gauge for measurement of surface heat flux and temperature using data from in-depth thermocouples10.1016/j.expthermflusci.2019.02.007 ↗
4. Influence of participating media on the radiation thermometry for surface temperature measurement10.1007/s11630-005-0060-9 ↗
5. Wei, Y., Gao, Y., Xiao, Z., Wang, G., Tian, M., and Liang, H. (2016). Ultrasonic Al2O3 ceramic thermometry in high-temperature oxidation environment. Sensors, 16.10.3390/s16111905 ↗
6. Antioxidation and High-Resolution Ultrasonic Temperature Sensor Based on Cr3+:MgAl2O4 Single Crystal Fiber10.1021/acs.cgd.0c00883 ↗
7. Radiation thermometry algorithms with emissivity constraint
8. Ultrasonic Temperature Measurement Technology for Molten Metals
9. Magnetostrictive properties and detection efficiency of TbDyFe/FeCo composite materials for nondestructive testing10.1016/j.jre.2018.04.020 ↗
10. Investigation of inductively coupled ultrasonic transducer system for NDE10.1109/TUFFC.2013.2674 ↗
11. Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators10.1016/j.ultras.2023.107205 ↗
12. Longitudinal guided waves confined in radius filler regions of composite joints10.1121/1.4955288 ↗
13. A micro resonant gas sensor with adjustable natural frequency10.1109/TIE.2020.2988243 ↗
14. Microstructure evolution and magnetic properties of annealed magnetostrictive Fe81Al19 coatings and their ultrasonic guided wave transducing performance10.1016/j.surfcoat.2019.03.039 ↗
15. Finite element analysis of the zero-crossing temperature of a long Fabry–Perot cavity10.1007/s12648-023-02619-w ↗
16. Composite Acoustic Metamaterial for Broadband Low-Frequency Acoustic Attenuation10.1103/PhysRevApplied.20.014011 ↗
17. Development of Polygonal Buffer Rods for Ultrasonic Pulse-Echo Measurements10.1088/1742-6596/520/1/012025 ↗
18. Álvarez-Arenas, G.T., and Camacho, J. (2019). Air-Coupled and Resonant Pulse-Echo Ultrasonic Technique. Sensors, 19.10.3390/s19102221 ↗
19. Exploring Acoustic-Temperature Response Characteristics of Al2O3 Crystals in High-Temperature Electromagnetic Environments10.1109/JSEN.2024.3512540 ↗
20. Design and Directional Growth of (Mg1-xZnx)(Al1-yCry)2O4 Single-Crystal Fibers for High-Sensitivity and High-Temperature Sensing Based on Lattice Doping Engineering and Acoustic Anisotropy10.1002/adfm.202103224 ↗
21. Fabrication and sensitivity optimization of garnet crystal-fiber ultrasonic temperature sensor10.1039/C9TC07071K ↗
22. Mechanical properties of Mo-Re alloy based on first-principles and machine learning potential function10.1016/j.mtcomm.2023.107796 ↗
23. Nonlinear propagation and anomalous absorption of ultrasound in liquid10.7498/aps.69.20200425 ↗
24. Nondestructive determination of longitudinal rail stress from guided wave dispersion properties10.1016/j.conbuildmat.2023.133618 ↗
25. Modal Analysis of the Piezoelectric Generation of Ultrasonic Guided Waves for Nondestructive Testing of Cylindrical Structures10.1134/S1061830907100087 ↗
26. Effective quality factor tuning mechanisms in micromechanical resonators10.1063/1.5027850 ↗
27. Three-dimensional finite element analysis for temperature filed of composite materials during the cure10.1108/MMMS-06-2021-0104 ↗
28. An ultrasonic guided wave excitation method at constant phase velocity using ultrasonic phased array probes10.1016/j.ultras.2019.106039 ↗
29. Multi-mode ultrasonic waves focusing in a variable focus technique for simultaneous sound-velocity and thickness measurement10.1016/j.apacoust.2019.107090 ↗
30. Li, Y., Zhang, Z., Hao, X., and Yin, W. (2018). A measurement system for time constant of thermocouple sensor based on high temperature furnace. Appl. Sci., 8.10.3390/app8122585 ↗
31. Research progress of ultrasonic temperature measurement technology in ultra-high temperature extreme environments
32. Non-contact in situ microwave material measurements for high temperature process monitoring10.1063/1.5079796 ↗
33. Lyu, F., Zhou, X., Ding, Z., Qiao, X., and Song, D. (2024). Application Research of Ultrasonic-Guided Wave Technology in Pipeline Corrosion Defect Detection: A Review. Coatings, 14.10.3390/coatings14030358 ↗