Applied Mechatronic: A Sensor-Based Modification of an External Fixator According to Mitkovic
Source abstract
Abstract
External fixators are frequently used to treat complex fractures with multiple bone fragments and soft tissue injuries. Inaccurate assessment of bone union and premature removal of the fixator may necessitate revisions and prolong treatment. The decision to remove an external fixator typically depends on an orthopedist’s experience. The accuracy of diagnosis can be improved by using a force sensor integrated into the modified external fixator according to Mitkovic. A sensor measuring axial compressive force is mounted between two vertical rods. Experiments with the modified external fixator were carried out using three different axial loads delivered by the universal electromechanical testing machine (UETM) and a sensor that detected the corresponding axial force. Springs with variable rigidity were used to simulate bone callus stiffness. Low rigidity springs represented a high elasticity callus, whereas high rigidity springs represented a callus with lower elasticity. The results show that the force detected by the sensor was nearly identical to the force delivered by the UETM while the callus did not form, decreased as spring rigidity increased, and eventually zeroed out as the leg healed. The findings indicated that using modified external fixator according to Mitkovic can help orthopedists assess bone healing more accurately.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Bone fractures and treatments · Shoulder Injury and Treatment · Orthopedic Surgery and Rehabilitation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Center for Applied Mathematics and Electronics, 11000 Belgrade, Serbia
Faculty of Mechanical Engineering, University of Nis, 18000 Nis, Serbia
Medical Faculty, University of Nis, 18000 Nis, Serbia
Faculty of Agriculture, University of Novi Sad, 21000 Novi Sad, Serbia
Center for Identification Technology, Faculty of Technical Sciences, University of Novi Sad, 21000 Novi Sad, Serbia
Funding
Provincial Secretariat for Higher Education and Scientific Research of Autonomous Province of Vojvodina, Serbia
References (32)
Show source-provided references
1. The epidemiology of open fractures in adults. A 15-year review10.1016/j.injury.2011.12.007 ↗
2. Sheen, J.R., Mabrouk, A., and Garla, V.V. (2025, May 13). Fracture healing overview, National Library of Medicine, Available online: https://www.ncbi.nlm.nih.gov/books/NBK551678/.
3. An engineering review of external fixators10.1016/j.medengphy.2021.11.002 ↗
4. Extra-articular distal tibia fractures: A mechanical evaluation of 4 different treatment methods10.1097/BOT.0b013e3181c29bc0 ↗
5. New concept in external fixation10.2298/ACI0502107M ↗
6. Cordelle, M.Z., Snelling, S.J., and Mouthuy, P.A. (2025). Skeletal muscle tissue engineering: From tissue regeneration to biorobotics. Cyborg Bionic Syst., 6.10.34133/cbsystems.0279 ↗
7. The epidemiology of open long bone fractures10.1016/S0020-1383(98)00125-9 ↗
8. Bisaccia, M., Cappiello, A., Meccariello, A., Meccariello, L., Rinonapoli, G., Falzarano, G., Medici, A., Ibaney Vicente, C., Piscitelli, L., and Stano, V. (2018). Nail or plate in the management of distal extra-articular tibial fractures, what is better? Valutation of outcomes. SICOT-J, 4.10.1051/sicotj/2017058 ↗
9. Gai, Y., Yin, Y., Guan, L., Zhang, S., Chen, J., Yang, J., Zhou, H., and Li, J. (2023). Rational design of bioactive materials for bone hemostasis and defect repair. Cyborg Bionic Syst., 4.10.34133/cbsystems.0058 ↗
10. Petrone, P., and Bratwaite, C.E. (2023). Long bone fractures. Acute Care Surgery in Geriatric Patients, Springer.10.1007/978-3-031-30651-8 ↗
11. Ekegren, C.L., Edwards, E.R., De Steiger, R., and Gabbe, B.J. (2018). Incidence, cost and predictors of non-union, delayed union and mal-union following long bone fracture. Int. J. Environ. Res. Public Health, 15.10.3390/ijerph15122845 ↗
12. Noorlander-Borgdorrf, M.P., Sekercan, A., Young-Afat, D.A., Bouman, M., Botman, M., and Ginnakkopoulos, G.F. (2024). Nationwide study on open tibial fractures in the Netherlands: Incidence, demographics and level of hospital care. Injury, 55.10.1016/j.injury.2024.111487 ↗
13. Fracture nonunion in long bones: A literature review of risk factors and surgical management10.1016/j.injury.2020.11.029 ↗
14. The role of external fixation and emergency fracture management in bovine orthopedics10.1016/S0749-0720(15)31354-2 ↗
15. External skeletal fixation of fractures in Cattle10.1016/j.cvfa.2013.12.001 ↗
16. Irvine-Smith, G. External skeletal fixation. Presented at the World Small Animal Veterinary Association World Congress Proceedings, Cape Town, South Africa, 16–19 September 2014.
17. Sellahewa, T., Weerashinghe, C., and Silva, P. (2021). Biomechanical evaluation method to optimize external fixator configuring in long bone fractures—Conceptual model and experimental validation using pilot study. Appl. Sci., 11.10.3390/app11188481 ↗
18. Strain sensor-based monitoring of smart orthopedic devices in lower limb fracture healing: A review
19. Kouassi, K.J.E., Cartiaux, O., Fonokue, L., Detrembleur, C., and Cornu, O. (2020). Biomechanical study of a low-cost external fixator for diaphyseal fractures of long bones. J. Orthop. Surg. Res., 15.10.1186/s13018-020-01777-5 ↗
20. Fracture healing: A review of clinical, imaging and laboratory diagnostic options10.1016/j.injury.2017.04.020 ↗
21. Sorriento, A., Chiurazzi, M., Fabbri, L., Scaglione, M., Dario, P., and Ciuti, G. (2021). A novel capacitive measurement device for longitudinal monitoring of bone fracture healing. Sensors, 21.10.3390/s21196694 ↗
22. Clinical study of a new design multifunction dynamic external fixation system for open tibial fracture
23. The relation between the dynamization of hexapod circular external fixator and tibial mechanical properties10.1111/os.13745 ↗
24. How does the stress in the fixation device change during different stages of bone healing in the treatment of fractures? A finite element study of external fixation for tibial fractures10.1111/os.14195 ↗
25. External fixation of segmental tibial shaft fractures10.1007/s00068-018-1041-5 ↗
26. External fixation of extra-articular open tibial fractures10.2478/afmnai-2018-0035 ↗
27. Dynamic external fixation of comminuted intra-articular fractures of the distal tibia (type C pilon fractures)
28. Mitkovic, M. (2020). Primena Metode i Aparata po Mitkoviću. Spoljna Fiksacija Kod Preloma Tibije, Srpska akademija nauka i umetnosti Ogranak u Nišu. Available online: https://www.mitkovic.org/news/pdf/IZVODZASAJT.pdf.
29. Ghiasi, M.S., Chen, J.E., Rodrigez, E.K., Vaziri, A., and Nazarian, A. (2019). Computational modeling of human bone fracture healing affected by different conditions of initial healing stage. BMC Musculoskelet. Disord., 20.10.1186/s12891-019-2854-z ↗
30. Bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo as a guide to removing a monoliteral external fixator safety10.1007/s00264-021-05116-z ↗
31. Steiner, M., Claes, L., Ignatius, A., Simon, U., and Wehner, T. (2014). Numerical simulation of callus healing for optimization of fracture fixation stiffness. PLoS ONE, 9.10.1371/journal.pone.0101370 ↗
32. Effect on callus development on the deformation of external fixation frames10.1007/s00264-012-1676-5 ↗