Empirical Validation of a Streamlined Three-Repetition Sit-to-Stand Protocol Using MAI Motion
Source abstract
Abstract
MAI Motion is a motion capture system designed to assess lower-limb biomechanics during functional movements like the sit-to-stand (STS) test. Determining how many repetitions are needed to obtain reliable measurements is critical for balancing data quality and participant burden. This study evaluates whether three repetitions (3x) of STS provide reliable data compared to five repetitions (5x). Three-dimensional videos of participants (n = 20) performing 5x STS movements were captured using MAI Motion. Primary measurements were the mean values of each joint angle and the coefficient of variation (CV). Statistical comparisons (including one way ANOVA followed by paired t-tests or non-parametric equivalents) determined whether differences in mean (DiM) values or CV existed between 3x and 5x. The analysis revealed minimal DiM angles between 3x and 5x. Variability, assessed via CV, showed no clinically meaningful differences. Although ankle angle, knee and hip abduction had higher CV values than the other metrics, 3x and 5x performed similarly. Participants reported that 3x required less effort than 5x, underscoring its potential for clinical application. These findings demonstrate that the MAI Motion system captures comparable biomechanical data to the 5x STS protocol when using a 3x approach. This supports the adoption of 3x as a practical alternative, reducing participant burden.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Stroke Rehabilitation and Recovery · Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Computer Science, University of Lincoln, Brayford Pool, Lincoln LN6 7TS, UK
MSK Doctors, MSK House, London Road, Silk Willoughby, Sleaford NG34 8NY, UK
RKEU Psychology, Health & Wellbeing, Bishop Grosseteste University, Longdales Road, Lincoln LN1 3DY, UK
United Lincolnshire Teaching Hospitals NHS Trust, 101 Manthorpe Rd, Grantham NG31 8DG, UK
Funding
Knowledge Transfer Partnership (KTP) programme
References (23)
Show source-provided references
1. Novel clinical applications of marker-less motion capture as a low-cost human motion analysis method in the detection and treatment of knee osteoarthritis
2. Armstrong, K., Zhang, L., Wen, Y., Willmott, A.P., Lee, P., and Ye, X. (2024). A marker-less human motion analysis system for motion-based biomarker identification and quantification in knee disorders. Front. Digit. Health, 6, Available online: https://www.frontiersin.org/journals/digital-health/articles/10.3389/fdgth.2024.1324511/full.10.3389/fdgth.2024.1324511 ↗
3. Quantifying Similarities Between MediaPipe and a Known Standard to Address Issues in Tracking 2D Upper Limb Trajectories: Proof of Concept Study10.2196/56682 ↗
4. A review of combined functional neuroimaging and motion capture for motor rehabilitation10.1186/s12984-023-01294-6 ↗
5. Kinematic analysis of the human body during sit-to-stand in healthy young adults10.1097/MD.0000000000026208 ↗
6. Whole-body movements during rising to standing from sitting10.1093/ptj/70.10.638 ↗
7. Determinants of the Sit-to-Stand Movement: A Review10.1093/ptj/82.9.866 ↗
8. The sit-to-stand muscle power test: An easy, inexpensive and portable procedure to assess muscle power in older people10.1016/j.exger.2018.08.006 ↗
9. Comprehensive Assessment of Lower Limb Function and Muscle Strength in Sarcopenia: Insights from the Sit-to-Stand Test10.4235/agmr.23.0205 ↗
10. The five-repetition sit-to-stand test as a functional outcome measure in COPD10.1136/thoraxjnl-2013-203576 ↗
11. A comparative study of the five-repetition sit-to-stand test and the 30-second sit-to-stand test to assess exercise tolerance in COPD patients10.2147/COPD.S173509 ↗
12. Onitsuka, K., Kubota, K., Yokoyama, M., Miyazawa, T., Hamaguchi, T., Taniguchi, H., Usuki, N., Miyamoto, S., Okazaki, K., and Murata, K. (2023). Clinical utility of markerless motion capture for kinematic evaluation of sit-to-stand during 30 s-CST at one year post total knee arthroplasty: A retrospective study. BMC Musculoskelet. Disord., 24.10.1186/s12891-023-06364-3 ↗
13. On the role of ageing and musculoskeletal pain on dynamic balance in manual workers10.1016/j.jelekin.2019.102374 ↗
14. Doi, S.A.R., and Williams, G.M. (2013). The Coefficient of Variation as an Index of Measurement Reliability. Methods of Clinical Epidemiology, Springer.10.1007/978-3-642-37131-8 ↗
15. The effect of sitting posture on the loads at cervico-thoracic and lumbosacral joints10.3233/THC-174717 ↗
16. Burdack, J., Horst, F., Aragonés, D., Eekhoff, A., and Schöllhorn, W.I. (2020). Fatigue-Related and Timescale-Dependent Changes in Individual Movement Patterns Identified Using Support Vector Machine. Front. Psychol., 11, Available online: https://www.frontiersin.org/journals/psychology/articles/10.3389/fpsyg.2020.551548/full.10.3389/fpsyg.2020.551548 ↗
17. The Impact of Fatigue on Performance and Biomechanical Variables—A Narrative Review with Prospective Methodology10.3390/biomechanics2040040 ↗
18. Thomas, D.T.R.S., Prabhakar, A.J., Dineshbhai, P.V., and Eapen, C. (2022). Hip abductor strengthening in patients diagnosed with knee osteoarthritis—A systematic review and meta-analysis. BMC Musculoskelet. Disord., 23.10.1186/s12891-022-05557-6 ↗
19. van Tittelboom, V., Alemdaroglu-Gurbuz, I., Hanssen, B., Heyrman, L., Feys, H., Desloovere, K., Calders, P., and Broeck, C.V.D. (2022). Reliability of Isokinetic Strength Assessments of Knee and Hip Using the Biodex System 4 Dynamometer and Associations with Functional Strength in Healthy Children. Front. Sports Act. Living, 4.10.3389/fspor.2022.817216 ↗
20. Performance on sit-to-stand tests in relation to measures of functional fitness and sarcopenia diagnosis in community-dwelling older adults10.1186/s11556-020-00255-5 ↗
21. In-Home Positioning for Remote Home Health Monitoring in Older Adults: Systematic Review10.2196/57320 ↗
22. Park, C., Mishra, R., Sharafkhaneh, A., Bryant, M.S., Nguyen, C., Torres, I., Naik, A.D., and Najafi, B. (2021). Digital Biomarker Representing Frailty Phenotypes: The Use of Machine Learning and Sensor-Based Sit-to-Stand Test. Sensors, 21.10.3390/s21093258 ↗
23. Digital Health Interventions among People Living with Frailty: A Scoping Review10.1016/j.jamda.2021.04.012 ↗