Tooth Movement Patterns Based on Traction Methods for Mandibular Canine Retraction Using Skeletal Anchorage: A Finite Element Analysis
Source abstract
Abstract
Objective: This study compared the tooth movement patterns of a power arm and a lever jig during mandibular canine retraction into a premolar extraction space using skeletal anchorage. Methods: A finite element model was developed based on anatomical structures. A mini-implant was placed between the mandibular second premolar and first molar, and canine retraction was simulated using a power arm and a lever jig. The lever jig’s vertical arm lengths were 6 mm, 8 mm, and 10 mm, corresponding to force application distances of 4.5 mm, 6.4 mm, and 8.2 mm from the archwire, matching the power arm. Finite element analysis was performed using linear mechanical properties and an explicit method. Results: With the power arm, increasing vertical length led to greater extrusion, while the posterior force remained unchanged. The lever jig also showed increased extrusion with length but to a lesser extent. Posterior force increased proportionally with the lever jig length. Initial displacement analysis showed greater extrusion and distal tipping with the power arm, while the lever jig suppressed extrusion and facilitated controlled tipping. Stress analysis revealed a more uniform periodontal ligament stress distribution with the lever jig. Conclusion: The lever jig minimizes extrusion and enhances force concentration posteriorly, promoting efficient distal movement.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: dental development and anomalies · Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthodontics, School of Dentistry, Wonkwang University, Iksan 54538, Republic of Korea
Wonkwang Dental Research Institute, Wonkwang University, Iksan 54538, Republic of Korea
Institute of Biomaterials and Implant, Wonkwang University, Iksan 54538, Republic of Korea
Postgraduate Orthodontic Program, Arizona School of Dentistry & Oral Health, A.T. Still University, Mesa, AZ 85206, USA
School of Dentistry, Kyung Hee University, Seoul 02447, Republic of Korea
References (24)
Show source-provided references
1. The center of resistance of a tooth: A review of the literature10.1007/s12551-023-01042-z ↗
2. Biomechanical analysis for total distalization of the maxillary dentition: A finite element study10.1016/j.ajodo.2020.04.029 ↗
3. Biomechanical analysis for total distalization of the mandibular dentition: A finite element study10.1016/j.ajodo.2018.05.014 ↗
4. Distalization pattern of whole maxillary dentition according to force application points10.4041/kjod.2015.45.1.20 ↗
5. A three-dimensional finite element analysis: Maxillary dentition distalization with the aid of microimplant in lingual orthodontics10.2147/IJGM.S337212 ↗
6. Biomechanical analysis for total arch distalization according to location of force application and types of temporary skeletal anchorage devices10.33777/cjkao.2021.11.2.89 ↗
7. Orthodontic Treatment of a Stage IV Periodontitis Patient Exhibiting Severe Attachment Loss and Pathological Tooth Migration10.33777/cjkao.2024.14.3.227 ↗
8. Chen, J., Zhu, D., Zhao, M., Cheng, Z., Pan, Y., and Liu, X. (2024). Three-dimensional finite element analysis of the optimal mechanical design for maximum inward movement of the anterior teeth with clear aligners. Sci. Rep., 14.10.1038/s41598-024-63907-x ↗
9. Tooth movement analysis of maxillary dentition distalization using clear aligners with buccal and palatal mini-screw anchorages: A finite element study10.1111/ocr.12826 ↗
10. A biomechanical case study on the optimal orthodontic force on the maxillary canine tooth based on finite element analysis10.1631/jzus.B1700195 ↗
11. Evaluation of stress and displacement of maxillary canine during the single canine retraction in the maxillary first premolar extraction cases-A finite element study10.1007/s00784-024-05590-w ↗
12. Biomechanical analysis of total arch maxillary distalization using infrazygomatic crest miniscrews: A finite element analysis study10.1186/s40510-024-00509-3 ↗
13. Numerical simulation of canine retraction by sliding mechanics10.1016/j.ajodo.2004.12.007 ↗
14. Analysis of stress in periodontium associated with orthodontic tooth movement: A three-dimensional finite element analysis10.1080/10255842.2021.1925255 ↗
15. Methods and applications of finite element analysis in dental trauma research: A scoping review10.1111/edt.12933 ↗
16. Application of finite element analysis in dentistry
17. Strains in periodontal ligament and alveolar bone associated with orthodontic tooth movement analyzed by finite element10.1111/j.1601-6343.2009.01445.x ↗
18. Moga, R.-A., Olteanu, C.D., and Delean, A.G. (2024). The importance of boundary conditions and failure criterion in finite element analysis accuracy—A comparative assessment of periodontal ligament biomechanical behavior. Appl. Sci., 14.10.3390/app14083370 ↗
19. A stress analysis of the periodontal ligament under various orthodontic loadings10.1093/ejo/13.3.231 ↗
20. Initial stress induced in periodontal tissue with diverse degrees of bone loss by an orthodontic force: Tridimensional analysis by means of the finite element method10.1016/0889-5406(93)70071-U ↗
21. A comparative FEM-study of tooth mobility using isotropic and anisotropic models of the periodontal ligament10.1016/S1350-4533(00)00055-2 ↗
22. Boundary-type hydrodynamic analysis of tooth movement10.1016/S0955-7997(00)00028-X ↗
23. Clinical effects of pre-adjusted edgewise orthodontic brackets: A systematic review and meta-analysis10.1093/ejo/cjt064 ↗
24. Frictional resistances of different bracket-wire combinations