Impact of Long-Term Storage on Mid-Infrared Spectral Patterns of Serum and Synovial Fluid of Dogs with Osteoarthritis
Source abstract
Abstract
Mid-infrared spectral (MIR) patterns of serum and synovial fluid (SF) are candidate biomarkers of osteoarthritis (OA). The impact of long-term storage on MIR spectral patterns was previously unknown. MIR spectra of canine serum (52 knee-OA, 49 control) and SF (51 knee-OA, 51 control) were obtained after short-term and long-term storage in −80 °C. Multilevel simultaneous component analysis and partial least squares discriminant analysis were used to evaluate the effect of time and compare the performance of predictive models for discriminating OA from controls. The median interval of storage between sample measurements was 5.7 years. Spectra obtained at two time points were significantly different (p < 0.0001); however, sample aging accounted for only 1.61% and 2.98% of the serum and SF profiles’ variability, respectively. Predictive models for discriminating serum of OA from controls for short-term storage showed 87.3 ± 3.7% sensitivity, 88.9 ± 2.4% specificity, and 88.1 ± 2.3% accuracy, while for long-term storage, they were 92.5 ± 2.6%, 97.1 ± 1.7%, and 94.8 ± 1.4%, respectively. Predictive models of short-term stored SF spectra had 97.3 ± 1.6% sensitivity, 89.4 ± 2.6% specificity, and 93.4 ± 1.6% accuracy, while for long-term storage they were 95.7 ± 2.1%, 95.7 ± 0.8%, and 95.8 ± 1.1%, respectively. Long-term storage of serum and SF resulted in significant differences in MIR spectral variables without significantly altering the performance of predictive algorithms for discriminating OA from controls.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Spectroscopy Techniques in Biomedical and Chemical Research · Infrared Thermography in Medicine · Osteoarthritis Treatment and Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, 625 Harrison St., West Lafayette, IN 47907, USA
Department of Chemistry, University of Rome La Sapienza, P.le Aldo Moro 5, I-00185 Rome, Italy
Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, 550 University Avenue, Charlottetown, PE C1A 4P3, Canada
References (29)
Show source-provided references
1. Zhao, Y., Feng, G., Zhang, J., Gong, R., Cai, C., and Feng, L. (2017). Effects of preanalytical frozen storage time and temperature on screening coagulation tests and factors VIII and IX activity. Sci. Rep., 7.10.1038/s41598-017-11777-x ↗
2. Effect of Repeated Freeze-Thaw on Serum Biomarkers Associated with Eye Disease10.12659/MSM.908567 ↗
3. Impact of freeze-thaw cycles on circulating inflammation marker measurements10.1016/j.cyto.2017.02.016 ↗
4. A novel diagnostic test for arthritis: Multivariate analysis of infrared spectra of synovial fluid10.1002/(SICI)1520-6343(1997)3:2<161::AID-BSPY9>3.0.CO;2-A ↗
5. Use of infrared spectroscopy for diagnosis of traumatic arthritis in horses10.2460/ajvr.67.8.1286 ↗
6. Identification of infrared absorption spectral characteristics of synovial fluid of horses with osteochondrosis of the tarsocrural joint10.2460/ajvr.68.5.517 ↗
7. Infrared-based detection of an osteoarthritis biomarker signature in the serum of rabbits with induced osteoarthritis10.1016/j.joca.2015.02.781 ↗
8. Malek, S., Marini, F., Rochat, M.C., Béraud, R., Wright, G.M., and Riley, C.B. (2020). Infrared spectroscopy of synovial fluid as a potential screening approach for the diagnosis of naturally occurring canine osteoarthritis associated with cranial cruciate ligament rupture. Osteoarthr. Cartil. Open, 2.10.1016/j.ocarto.2020.100120 ↗
9. Infrared spectroscopy of serum as a potential diagnostic screening approach for naturally occurring canine osteoarthritis associated with cranial cruciate ligament rupture10.1016/j.joca.2019.10.006 ↗
10. Evaluation of transmission infrared spectroscopy and digital and optical refractometers to identify low immunoglobulin G concentrations in alpaca serum
11. Measurement of serum immunoglobulin G in dairy cattle using Fourier-transform infrared spectroscopy: A reagent free approach10.1016/j.tvjl.2014.09.014 ↗
12. Utility of Plasma Protein Biomarkers and Mid-Infrared Spectroscopy for Diagnosing Fracture-Related Infections: A Pilot Study10.1097/BOT.0000000000002379 ↗
13. Smith, B.C. (2011). Fundamentals of Fourier Transform Infrared Spectroscopy, CRC Press. [2nd ed.].10.1201/b10777 ↗
14. Multianalyte Serum Assays from Mid-IR Spectra of Dry Films on Glass Slides10.1366/0003702001950265 ↗
15. Use of Fourier-Transform Infrared Spectroscopy to Quantify Immunoglobulin G Concentrations in Alpaca Serum10.1111/jvim.12258 ↗
16. Smoothing and Differentiation of Data by Simplified Least Squares Procedures10.1021/ac60214a047 ↗
17. MultiLevel simultaneous component analysis: A computational shortcut and software package10.3758/s13428-015-0626-8 ↗
18. Multilevel component analysis of time-resolved metabolic fingerprinting data10.1016/j.aca.2004.09.074 ↗
19. Vis, D.J., Westerhuis, J.A., Smilde, A.K., and van der Greef, J. (2007). Statistical validation of megavariate effects in ASCA. BMC Bioinform., 8.10.1186/1471-2105-8-322 ↗
20. Chemometric methods for classification and feature selection
21. Gelsema, E.S., and Kanal, L.N. (1986). PLS discriminant plots. Pattern Recognition in Practice II, Elsevier.
22. Wold, S., Martens, H., and Wold, H. (1982, January 22–24). The multivariate calibration problem in chemistry solved by the PLS methods. Proceedings of the Matrix Pencils, Pite Havsbad, Sweden.10.1007/BFb0062108 ↗
23. Double-check: Validation of diagnostic statistics for PLS-DA models in metabolomics studies10.1007/s11306-011-0330-3 ↗
24. Assessment of PLSDA cross validation10.1007/s11306-007-0099-6 ↗
25. Jaggard, M.K.J., Boulange, C.L., Graca, G., Akhbari, P., Vaghela, U., Bhattacharya, R., Williams, H.R.T., Lindon, J.C., and Gupte, C.M. (2021). The influence of sample collection, handling and low temperature storage upon NMR metabolic profiling analysis in human synovial fluid. J. Pharm. Biomed. Anal., 197.10.1016/j.jpba.2021.113942 ↗
26. Optimization of Synovial Fluid Collection and Processing for NMR Metabolomics and LC-MS/MS Proteomics10.1021/acs.jproteome.0c00035 ↗
27. Hackshaw, K.V., Miller, J.S., Aykas, D.P., and Rodriguez-Saona, L. (2020). Vibrational Spectroscopy for Identification of Metabolites in Biologic Samples. Molecules, 25.10.3390/molecules25204725 ↗
28. The effects of freeze/thawing on human synovial fluid observed by 500 MHz 1H magnetic resonance spectroscopy
29. Effect of freezing and thawing of serum on the immunoassay of lipoprotein(a)10.1093/clinchem/38.9.1873 ↗