Abstract
Due to advances in power electronics technology and the evolution of automation devices, the number of electrical devices that are sensitive to power quality is rapidly increasing, and for this reason, users are increasing their demand for high quality. To meet power quality demands, many power conversion devices are used, including dynamic voltage restorers (DVRs). DVRs are recognized as devices that can effectively manage problems such as voltage segments, swells, and harmonics. DVR control requires many samples for harmonic compensation, which has the disadvantage of being complicated to implement due to fast digital signal processing computation and the application of the cyclic discrete Fourier transform. In this paper, a high-precision DVR system configuration is proposed that compensates for harmonics using a periodically equivalent time-interval sampling technique and a novel circular-structured memory filter. The proposed circular-structured multi-pointer memory filter is an effective filter algorithm for high-precision input voltage measurement because it can remove noise and compensate for the delay of the phase angle of the filter in voltage measurement. A simulation and DVR prototype system were built, and the feasibility and effectiveness of the phase angle multi-filter voltage detection method and the compensation method were verified by experiments.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Quality and Harmonics · Power System Optimization and Stability · Microgrid Control and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electrical Engineering, Honam University, 417 Eodeung-daero, Gwangsan-gu, Gwangju 62399, Republic of Korea
Funding
National Research Foundation of Korea (NRF) funded by the Ministry of Education (MOE)
References (20)
Show source-provided references
1. Power systems of the future10.1109/39.814649 ↗
2. Current Status and Issues of Concern for the Integration of Distributed Generation Into Electricity Networks10.1109/JSYST.2014.2305282 ↗
3. Gunther, E.W. (2001, January 15–19). Interharmonics in power systems. Proceedings of the 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262), Vancouver, BC, Canada.10.1109/PESS.2001.970156 ↗
4. Benysek, G., and Pasko, M. (2012). Power Theories for Improved Power Quality, Springer.10.1007/978-1-4471-2786-4 ↗
5. Coordinated Control of OLTC and Energy Storage for Voltage Regulation in Distribution Network with High PV Penetration10.1109/TSTE.2020.2991017 ↗
6. Review of control strategies for voltage regulation of the smart distribution network with high penetration of renewable distributed generation10.1016/j.rser.2016.06.030 ↗
7. Enhancing PV penetration in LV networks using reactive power control and on load tap changer with existing transformers10.1109/ACCESS.2017.2784840 ↗
8. A review on voltage control methods using on-load tap changer transformers for networks with renewable energy sources10.1016/j.rser.2016.05.016 ↗
9. Optimal Tap Setting of Voltage Regulation Transformers Using Batch Reinforcement Learning10.1109/TPWRS.2019.2948132 ↗
10. Moghassemi, A., and Padmanaban, S. (2020). Dynamic Voltage Restorer (DVR): A Comprehensive Review of Topologies, Power Converters, Control Methods, and Modified Configurations. Energies, 13.10.3390/en13164152 ↗
11. Ram, G., Prasanth, V., Bauer, P., and Barthlein, E.-M. (2014, January 21–24). Comparative analysis of on-load tap changing (OLTC) transformer topologies. Proceedings of the 2014 16th International Power Electronics and Motion Control Conference (PEMC), Antalya, Turkey.10.1109/EPEPEMC.2014.6980624 ↗
12. Automatic Voltage Stabilization Using IGBT Based on Load Tap Changer with Fault Consideration10.1109/ACCESS.2021.3079507 ↗
13. Design of a Power-Electronic-Assisted OLTC for Grid Voltage Regulation10.1109/TPWRD.2014.2371539 ↗
14. A Novel Switching Methodology for Low Voltage Static Regulators10.1109/ACCESS.2022.3152205 ↗
15. Compensation of distribution system voltage using DVR10.1109/TPWRD.2002.803839 ↗
16. Udayakiran, C., and Vali, S.H. (2017, January 5–7). Design of Battery Energy Storage System (BESS) Support Dynamic Voltage Restorer (DVR) to Reduce the Rating of Voltage Source Converter (VSC) Applied to IEEE 11, 33 & 69 Bus Systems. Proceedings of the 2017 IEEE 7th International Advance Computing Conference (IACC), Hyderabad, India.10.1109/IACC.2017.0104 ↗
17. Analysis of series compensation and dc-link voltage controls of a transformerless self-charging dynamic voltage restorer10.1109/TPWRD.2004.829866 ↗
18. Ansal, V., Ravikumar, K., and Parthiban, P. (2016, January 21–23). Transformerless Dynamic Voltage Restorer for voltage sag mitigation. Proceedings of the 2016 Biennial International Conference on Power and Energy Systems: Towards Sustainable Energy (PESTSE), Bengaluru, India.10.1109/PESTSE.2016.7516426 ↗
19. Ghosh, A., and Ledwich, G. (February, January 28). Structures and control of a dynamic voltage regulator (DVR). Proceedings of the 2001 IEEE Power Engineering Society Winter Meeting, Conference Proceedings (Cat. No.01CH37194), Columbus, OH, USA.
20. Dynamic voltage restorer—A comprehensive review10.1016/j.egyr.2021.09.004 ↗