Optical Characterization of a Rotationally Asymmetric Refractive Multifocal Intraocular Lens Compared to a Standard Monofocal One
Source abstract
Abstract
This study compares a standard monofocal intraocular lens (IOL) with two rotationally asymmetric refractive multifocal IOLs, analyzing power profiles and wavefront data across three nominal powers. Tested IOLs included monofocal Acunex AN6 and multifocal AN6V (addition +1.50 D) and AN6VM (addition +3.00 D) by Teleon Surgical, at powers +10.00 D, +20.00 D, and +30.00 D. Using NIMO TR1504, power profiles, spherical aberration, and coma were analyzed. Multifocal lenses displayed an asymmetrical design, with zones for far and near vision and a central notch for far power. The multifocal AN6V and AN6VM showed neutral spherical aberration in the center, increasing to positive values, and finally achieving negative values towards the periphery. The vertical coma coefficient [Z(3:−1)] remains almost stable for the monofocal IOLs. The lower-addition multifocal IOLs induce primary vertical coma of +0.11 microns at 3 mm away from the lens center compared to +0.21 microns obtained with the high-addition lens. We can conclude that the multifocal AN6V and AN6VM lenses display an asymmetrical design. The final addition provided by these lenses depends on its nominal power. The variation of SA with optic size is more pronounced for the monofocal model, and it is dependent on the nominal power.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Ophthalmology and Visual Impairment Studies · Corneal surgery and disorders · Intraocular Surgery and Lenses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Departamento de Óptica y Optometría y Ciencias de la Visión, Universitat de València, Doctor Moliner 50, E-46100 Burjassot, Spain
Departamento de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, E-28037 Madrid, Spain
Departamento de Óptica, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, E-28037 Madrid, Spain
Funding
Spanish State Research Agency
References (21)
Show source-provided references
1. Effectiveness of multifocal and monofocal intraocular lenses for cataract surgery and lens replacement: A systematic review and meta-analysis10.1007/s00417-018-04218-6 ↗
2. Long-term Prevalence of Opacification of a Hydrophylic Acrylic Rotationally Asymmetric Refractive Multifocal Intraocular Lens
3. Visual and Refractive Outcomes Following Exchange of an Opacified Multifocal Intraocular Lens10.2147/OPTH.S362930 ↗
4. Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision10.1016/j.jcrs.2014.07.045 ↗
5. Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens10.3928/1081597X-20160217-06 ↗
6. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
7. (2024, March 01). Acunex AN6 Information Brochure. Available online: https://www.teleon-surgical.com/media/salesfolder-acunex_en.pdf.
8. (2024, March 01). Acunex AN6V Information Brochure. Available online: https://www.teleon-surgical.com/media/qf2186v3-6seiter-tech-acunex-vario-duo-dina4-202305-en-digital.pdf.
9. (2024, March 01). Acunex AN6VM Information Brochure. Available online: https://www.teleon-surgical.com/media/salesfolder-acunex-variomax-en.pdf.
10. Phase-shifting schlieren: High-resolution quantitative schlieren that uses the phase-shifting technique principle10.1364/AO.42.005046 ↗
11. Gómez-Pedrero, J.A., Albarrán-Diego, C., García-Montero, M., Garzón, N., and Gonzalez-Fernandez, V. (2023). Influence of Instrumental Factors in the Measurement of Power Profiles of Intraocular Lenses with a Commercial Deflectometer. Appl. Sci., 13.10.1364/opticaopen.23559930 ↗
12. Optical and Clinical Outcomes of an Enhanced Monofocal Intraocular Lens for High Hyperopia10.3928/1081597X-20220802-01 ↗
13. Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment10.1016/j.jcrs.2017.08.013 ↗
14. Borkenstein, A.F., Borkenstein, E.M., and Schmid, R. (2022). Analysis of a novel hydrophobic acrylic enhanced monofocal intraocular lens compared to its standard monofocal type on the optical bench. BMC Ophthalmol., 22.10.1186/s12886-022-02584-8 ↗
15. Assessment of Pupil Size and Angle Kappa in Refractive Surgery: A Population-Based Epidemiological Study in Predominantly American Caucasians
16. The relationship of Central Corneal Thickness (CCT) to Thinnest Central Cornea (TCC) in healthy adults10.1016/j.clae.2008.07.006 ↗
17. On the Chromatic Dispersion of Hydrophobic and Hydrophilic Intraocular Lenses10.1097/OPX.0000000000001495 ↗
18. Correlation of Visual Performance With Quality of Life and Intraocular Aberrometric Profile in Patients Implanted With Rotationally Asymmetric Multifocal IOLs10.3928/1081597X-20111213-02 ↗
19. Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens10.1016/j.jcrs.2010.08.043 ↗
20. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens10.3928/1081597X-20161206-03 ↗
21. Improvement in vision with inverted placement of an asymmetric refractive multifocal intraocular lens10.1016/j.jcrs.2014.02.012 ↗