journal article·2024-04-17Open access

Usefulness Evaluation for Nonlocal Means Algorithm in Low-Dose Computed Tomography with Various Iterative Reconstruction Intensities and Kernels: A Pilot Study

Chaehyeon Song, Yubin Jin, Jina Shim, Seong-Hyeon Kang, Youngjin Lee

Applied Sciences· Volume 14· Issue 8

Abstract

The aim of this study was to evaluate the application feasibility of the nonlocal means (NLM) noise reduction algorithm in low-dose computed tomography (CT) images using an advanced modeled iterative reconstruction (ADMIRE) iterative reconstruction technique-based tin filter with various applied parameters. Low-dose CT images were based on high pitch and tin filters and acquired using slices of the aortic arch, the four chambers of the heart, and the end of the heart. Intensities A2 and A3 as well as kernels B40 and B59 were used as the parameters for the ADMIRE technique. The NLM denoising algorithm was modeled based on the principle of weighting between pixels; the contrast-to-noise ratio (CNR), edge rise distance (ERD), and blind/referenceless image spatial quality evaluator (BRISQUE) were used as image quality evaluation parameters. The CNR result was the highest, with an average of 43.51 in three slices when the proposed NLM denoising algorithm was applied to CT images acquired using the ADMIRE intensity 2 and B59 kernel. The ERD results were similar to those obtained using the ADMIRE intensity 2 and B59 kernel in the CT image acquired using the proposed method. In addition, BRISQUE, which can evaluate the overall image quality, showed a similar trend to the ERD results. In conclusion, the NLM noise reduction algorithm is expected to maximize image quality by preserving efficient edge information while improving noise characteristics in low-dose CT examinations.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Radiation Dose and Imaging · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Radiological Science, Gachon University, 191, Hambakmoero, Yeonsu-gu, Incheon 21936, Republic of Korea

Department of Diagnostic Radiology, Severance Hospital, 50-1, Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea

Department of Biomedical Engineering, Eulji University, 553, Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea

Funding

National Foundation of Korea (NRF)

References (21)

Show source-provided references
1. Computed Tomography Screening and Lung Cancer Outcomes10.1001/jama.297.9.953 ↗
2. Choi, S.J., Ahn, S.J., Park, S.H., Park, S.H., Pak, S.Y., Choi, J.W., Shim, Y.S., Jeong, Y.M., and Kim, B. (2020). Dual-source abdominopelvic computed tomography: Comparison of image quality and radiation dose of 80 kVp and 80/150 kVp with tin filter. PLoS ONE, 15.10.1371/journal.pone.0231431 ↗
3. Clinical evaluation of a deep-learning model for automatic scoring of the Alberta stroke program early CT score on non-contrast CT10.1136/jnis-2022-019970 ↗
4. Cao, C.-F., Ma, K.-L., Shan, H., Liu, T.-F., Zhao, S.-Q., Wan, Y., Zhang, J., and Wang, H.-Q. (2022). CT Scans and Cancer Risks: A Systematic Review and Dose-response Meta-analysis. BMC Cancer, 22.10.1186/s12885-022-10310-2 ↗
5. Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: Data linkage study of 11 million Australians10.1136/bmj.f2360 ↗
6. Computed Tomography—An Increasing Source of Radiation Exposure10.1056/NEJMra072149 ↗
7. Low-dose computed tomography image restoration using previous normal-dose scan10.1118/1.3638125 ↗
8. Early Adversity and Critical Periods: Neurodevelopmental Consequences of Violating the Expectable Environment10.1016/j.tins.2020.01.002 ↗
9. Prospective evaluation of ultra-low-dose contrast-enhanced 100-kV abdominal computed tomography with tin filter: Effect on radiation dose reduction and image quality with a third-generation dual-source CT system10.1007/s00330-018-5750-2 ↗
10. Simple Adaptive Median Filter for the Removal of Impulse Noise from Highly Corrupted Images10.1109/TCE.2008.4711254 ↗
11. New Insights into the Noise Reduction Wiener Filter10.1109/TSA.2005.860851 ↗
12. Noise reduction for low-dose X-ray CT based on fuzzy logical in stationary wavelet domain10.1016/j.ijleo.2012.10.044 ↗
13. CT image denoising using NLM and its method noise thresholding10.1007/s11042-018-6897-1 ↗
14. CT image denoising using NLM and correlation-based wavelet packet thresholding10.1049/iet-ipr.2017.0639 ↗
15. Low-dose CT statistical iterative reconstruction viamodified MRF regularization10.1016/j.cmpb.2015.10.004 ↗
16. Comparison of a Deep Learning-Based Reconstruction Algorithm with Filtered Back Projection and Iterative Reconstruction Algorithms for Pediatric Abdominopelvic CT10.3348/kjr.2021.0466 ↗
17. Ultralow-dose CT with tin filtration for detection of solid and sub solid pulmonary nodules: A phantom study10.1259/bjr.20150389 ↗
18. NLM based magnetic resonance image denoising—A review10.1016/j.bspc.2018.08.031 ↗
19. Quantitative comparison of noise texture across CT scanners from different manufacturers10.1118/1.4752209 ↗
20. Buades, A., and Morel, J.-M. (2005, January 20–26). A non-local algorithm for image denoising. Proceedings of the 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR’05), San Diego, CA, USA.
21. Making a “Completely Blind” Image Quality Analyzer10.1109/LSP.2012.2227726 ↗