journal article·2022-10-06Open access

Asymmetric Etalon Effect in Fold-Type Optical Feedback Cavity-Enhanced Absorption Spectroscopy

Yunzheng Wang, Shiyu Guan, Huilin Cao, Zhongqi Tan

Applied Sciences· Volume 12· Issue 19

Abstract

To further improve the performance of cavity-enhanced spectroscopy systems, a high-quality U-cavity system was established. In the process of the experiment, an asymmetric ripple effect, which is different from the previous etalon effect, was found, which seriously affects the performance of the spectral system. This unique phenomenon mainly manifests in the different amplitudes of the fluctuations of the spectral curves measured by the folding mirror and the end mirror in the U-cavity system. Based on multi-beam interference theory, we analyzed the characteristics of the transmission spectrum of each mirror in the presence of the etalon effect at the end mirror, and obtained the following conclusions: for the U-cavity system, the strength of the etalon effect of each mirror is inversely proportional to its transmission loss value, that is, the larger the loss, the smaller the ripple of the transmission spectrum, and vice versa. In order to eliminate this effect, the most effective way is to eliminate the etalon effect caused by the light feedback of the end mirror. After improving the system, the minimum detectable absorption coefficient of αmin=8.33×10−9cm−1 is obtained with this U-shape Optical Feedback Cavity-Enhanced Absorption Spectroscopy. These works are valuable references for the design of folded Cavity-Enhanced Absorption Spectroscopy systems and have potential for laser wavelength calibration and measurement of a mirror’s reflectance.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spectroscopy and Laser Applications · Photonic and Optical Devices · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Advance Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China

Funding

National Natural Science Foundation of China · Hunan Provincial Innovation Foundation for Postgraduate

References (25)

Show source-provided references
1. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits10.3390/s91008230 ↗
2. Applying CEAS method to UV, VIS, and IR spectroscopy sensors
3. Luo, Z., Tan, Z., and Long, X. (2019). Application of Near-Infrared Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) to the Detection of Ammonia in Exhaled Human Breath. Sensors, 19.10.3390/s19173686 ↗
4. A Novel Solid State Non-Dispersive Infrared CO2 Gas Sensor Compatible with Wireless and Portable Deployment10.3390/s130607079 ↗
5. Integral absorbance measurement for a non-uniform flow field using wavelength modulation absorption spectroscopy10.1364/AO.425183 ↗
6. Two schemes for trace detection using cavity ringdown spectroscopy10.1007/s00340-003-1363-8 ↗
7. Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy10.1063/1.1149176 ↗
8. Incoherent broad-band cavity-enhanced absorption spectroscopy
9. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources10.1063/1.1139895 ↗
10. Optical-feedback cavity-enhanced absorption spectroscopy in a linear cavity: Model and experiments10.1007/s00340-015-6140-y ↗
11. Frequency-stabilized single-mode cavity ring-down apparatus for high-resolution absorption spectroscopy10.1063/1.1666984 ↗
12. Fast, low-noise, mode-by-mode, cavity-enhanced absorption spectroscopy by diode-laser self-locking10.1007/s00340-005-1828-z ↗
13. The Study of cavity enhanced absorption spectroscopy and application
14. Frequency stabilization of semiconductor lasers by resonant optical feedback10.1364/OL.12.000876 ↗
15. Mode-by-mode optical feedback: Cavity ringdown spectroscopy10.1007/s00340-007-2618-6 ↗
16. Very high finesse optical-feedback cavity-enhanced absorption spectrometer for low concentration water vapor isotope analyses10.1364/OL.39.001795 ↗
17. Guan, S., Chen, D., Cao, H., and Tan, Z. (2021). Study of a Mode Separation Due to Polarization Existing in a Cavity-Enhanced Absorption Spectroscopy. Sensors, 21.10.3390/s21217101 ↗
18. Cw Integrated cavity output spectroscopy10.1016/S0009-2614(99)00547-3 ↗
19. The HITRAN2020 molecular spectroscopic database
20. Study of a periodic spectral fluctuation existing in a fibered optical feedback cavity-enhanced absorption spectroscopy (OF-CEAS)10.1186/s41476-019-0120-5 ↗
21. Etaloning Effects in Continuous-Wave Cavity Ring down Spectroscopy10.3788/CJL20083510.1563 ↗
22. A Fabry-Perot Etalon with an Ultralow Expansion Ceramic Spacer10.7567/JJAP.52.032402 ↗
23. Tunable narrowband filter based on a combination of Fabry-Perot etalon and volume Bragg grating10.1364/OL.31.002417 ↗
24. Alignment of resonant optical cavities10.1364/AO.23.002944 ↗
25. Laser beams and resonators: The 1960s10.1109/2944.902192 ↗