journal article·2021-08-25Open access

Application of a Novel Attachable Magnetic Nerve Stimulating Probe in Intraoperative Lumbar Pedicle Screw Placement: A Porcine Model Study

Tae Sik Goh, Sung-Chan Shin, Hyun-Keun Kwon, Eui-Suk Sung, Se Bin Jun, Byung-Joo Lee, Jung Sub Lee

Applied Sciences· Volume 11· Issue 17

Abstract

Pedicle screw instrumentation is a fundamental technique in lumbar spine surgery. However, several complications could occur when placing a pedicle screw, the most serious being damage to the neural structures. We developed an attachable magnetic nerve stimulating probe used for triggered electromyography (t-EMG) to avoid these. This study aimed to investigate the efficacy of this probe for intraoperative neuromonitoring (ION) during lumbar pedicle screw placement in a porcine model. Forty pedicle screws were inserted bilaterally into the pedicles of the fourth and fifth lumbar vertebrae of five pigs; 20 were inserted typically into the pedicle without nerve damage (Group A), and the other 20 were inserted through the broken medial wall of the pedicle to permit contact with the neural structures (Group B). We measured the triggered threshold for pedicle screw placement through the conventional nerve probe and our newly developed magnetic probe. There was no significant difference in the triggered threshold between the two instruments (p = 0.828). Our newly developed magnetic stimulating probe can be attached to a screwdriver, thus preventing real-time screw malpositioning and making it practical and equally safe. This probe could become indispensable in revision spine surgeries with severe adhesions or endoscopic spine surgeries.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Spinal Fractures and Fixation Techniques · Intraoperative Neuromonitoring and Anesthetic Effects · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthopaedic Surgery, Biomedical Research Institute, Pusan National University Hospital, Busan 49241, Korea

Department of Otorhinolaryngology-Head and Neck Surgery, Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University, Pusan National University Hospital, Busan 49241, Korea

Department of Otolaryngology-Head and Neck Surgery, Research Institute for Convergence of Biomedical Science and Technology, College of Medicine, Pusan National University, Yangsan 46241, Korea

Funding

Ministry of Education · Ministry of Health and Welfare

References (21)

Show source-provided references
1. Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique10.1097/00002517-200012000-00005 ↗
2. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis10.1097/00007632-199710010-00008 ↗
3. Observer reliability in evaluating pedicle screw placement using computed tomography10.1007/s00264-006-0230-8 ↗
4. Accuracy of pedicle screw placement in the thoracic and lumbosacral spine using a conventional intraoperative fluoroscopy-guided technique: A national neurosurgical education and training center analysis of 1236 consecutive screws10.1016/j.wneu.2014.06.023 ↗
5. Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement10.1097/01.BRS.0000049926.43292.93 ↗
6. Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members10.1097/00007632-199311000-00015 ↗
7. Accuracy and safety of percutaneous lumbosacral pedicle screw placement using dual-planar intraoperative fluoroscopy10.4184/asj.2018.12.2.238 ↗
8. The accuracy of intraoperative O-arm images for the assessment of pedicle screw postion10.1097/BRS.0b013e3182257cae ↗
9. Intraoperative evoked EMG monitoring in an animal model. A new technique for evaluating pedicle screw placement10.1097/00007632-199210000-00017 ↗
10. Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Initial clinical results10.1097/00007632-199412150-00008 ↗
11. Triggered electromyographic threshold for accuracy of pedicle screw placement. An animal model and clinical correlation10.1097/00007632-199507150-00006 ↗
12. Triggered electromyographic threshold for accuracy of thoracic pedicle screw placement in a porcine model10.1097/00007632-200111150-00017 ↗
13. Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: Analysis of 4857 screws10.1097/BRS.0b013e31815a524f ↗
14. Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement?10.1097/00007632-200209150-00012 ↗
15. Application of attachable magnetic nerve stimulator in intraoperative facial nerve monitoring during ear surgery10.1177/0194599820907912 ↗
16. Development of a novel detachable magnetic nerve stimulator for intraoperative neuromonitoring10.1007/s00268-017-4159-4 ↗
17. Evaluation of intrapedicular screw position using intraoperative evoked electromyography10.1097/00007632-199505000-00015 ↗
18. Safe pedicle screw placement in thoracic scoliotic curves using t-EMG: Stimulation threshold variability at concavity and convexity in apex segments10.1097/BRS.0b013e31823b077b ↗
19. Can triggered electromyography thresholds assure accurate pedicle screw placements? A systematic review and meta-analysis of diagnostic test accuracy10.1016/j.clinph.2014.11.026 ↗
20. Accuracy of robot-assisted pedicle screw insertion in adolescent idiopathic scoliosis: Is triggered electromyographic pedicle screw stimulation necessary?10.21037/jss.2018.04.01 ↗
21. Developmnet of an attachable endoscopic nerve stimulator for intraoperative neuromonitoring during endoscopic or robotic thyroidectomy10.1177/0194599817742841 ↗