Synchrotron X-ray Irradiation of a Rat’s Head Model: Monte Carlo Study of Chromatic Gel Dosimetry
Source abstract
Abstract
Accurate treatment planning in radiotherapy essentially decreases damage to healthy tissue surrounding the tumor. Due to plans to use a direct, highly collimated, narrow beam with high intensity to treat small area tumors, researchers have studied microbeam radiation therapy extensively. Using a synchrotron beam as the radiation source may help to limit damage, but treatment planning using computerized simulations and dosimetry is still necessary to achieve optimal results. For this purpose, PDA-gel dosimeters were developed and their sensitivity around a 150 keV induced synchrotron X-ray radiation beam was examined via Monte Carlo simulations using the EGS5 code system. The microbeam development is now at the animal study stage. In this study, we simulate the irradiation of a rat’s brain. The simulation results obtained spectra for two types of PDA-gel dosimeters that were compared with the spectrum obtained in a modelized brain tumor of a rat. Additionally, percentage depth dose curves were calculated for the brain tissue and the two gels. Correction equations for the dosimeters were obtained from the dose-difference plots. For further references, these equations can be used to calculate the actual dose in a brain tumor in a rat. The Monte Carlo simulations demonstrate that PDA-gel dosimeters can be used for treatment planning using synchrotron irradiations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Therapy and Dosimetry · Radiopharmaceutical Chemistry and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biotechnology Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105, Israel
Radiotherapy Department, Institute of Oncology, Soroka University Medical Center, Beer-Sheva 84100, Israel
Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105, Israel
Funding
Ministry of Science and Technology, Israel
References (19)
Show source-provided references
1. Polymer gel dosimetry10.1088/0031-9155/55/5/R01 ↗
2. Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter10.1088/0031-9155/39/9/010 ↗
3. Review of gel dosimetry: A personal reflection10.1088/1742-6596/777/1/012029 ↗
4. Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging10.1088/0031-9155/50/16/015 ↗
5. Characterization of novel polydiacetylene gel dosimeter for radiotherapy10.1088/2057-1976/aba638 ↗
6. Structural transitions in polydiacetylene langmuir films10.1021/la8029038 ↗
7. Effect of metal cations on polydiacetylene langmuir films10.1021/la204735t ↗
8. Khan, F.M., Gibbons, J.P., and Sperduto, P.W. (2016). Khan’s Treatment Planning in Radiation Oncology, Wolters Kluwer. [4th ed.].
9. Report of the AAPM task group No. 105: Issues associated with clinical implementation of monte carlo-based photon and electron external beam treatment planning10.1118/1.2795842 ↗
10. Bjarngard, B.E., and Attix, F.H. (1990). Monte Carlo Techniques of Electron and Photon Transport for Radiation Dosimetry, National Research Council of Canada.
11. Briesmeister, J.f. (1993). MCNP-A General Monte Carlo Code for Neutron and Photon Transport, Los Alamos National Laboratory.
12. Electron-photon monte carlo calculations: The ETRAN Code10.1016/0883-2889(91)90050-B ↗
13. Hirayama, H., Namito, Y., Nelson, W.R., Bielajew, A.F., Wilderman, S.J., and Michigan, U. (2005). The EGS5 Code System, in KEK Reports, United States Department of Energy.10.2172/877459 ↗
14. Optimization of variance reduction techniques used in EGSnrc monte carlo codes10.4103/jmp.JMP_132_17 ↗
15. Review of fast Monte Carlo codes for dose calculation in radiation therapy treatment planning10.4103/2228-7477.83522 ↗
16. Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system410.1088/0031-9155/45/9/304 ↗
17. Age-dependent changes in material properties of the brain and braincase of the rat10.1089/089771503770802853 ↗
18. Photon Sciences Division (2018). High Energy Engineering X-ray Scattering (HEX) Facility, Preliminary Design Report for the NSLS-II Project.
19. Synchrotron radiation as an absolute standard source10.1016/0029-554X(80)90619-9 ↗