Biomechanical Comparison of Different Volar Screw Placements for Horizontal Oblique Scaphoid Fractures
Source abstract
Abstract
Recently, some surgeons reported that most scaphoid waist fractures were horizontal oblique and not transverse in orientation. Therefore, this cadaveric study aimed to biomechanically compare fixation strength between central and eccentric screw placements for the volar fixation of this most common scaphoid waist fracture. Eight matched pairs of fresh-frozen forearm cadaver specimens were prepared for testing and randomly assigned to two groups: group I specimens were fixed by screws in a central placement, and group II specimens were fixed by screws in an eccentric placement. Horizontal oblique osteotomy was performed along the scaphoid waist. Then, each specimen was placed under the increasing load of a pneumatically driven plunger. We recorded stiffness, load to failure, and failure mechanisms between the central and eccentric screw placement groups. Stiffness was higher in central screw placement (74.1 N/mm) than in eccentric screw placement (29.39 N/mm). The median loads to failure in groups I and II were 54.14 and 26.22 N, respectively. In this biomechanical model, we demonstrated that central screw placement is superior to eccentric placement in terms of fixation strength. However, further clinical investigation is warranted to evaluate whether the different screw placements for volar approach of horizontal oblique scaphoid fractures affect the clinical outcomes.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthopedic Surgery and Rehabilitation · Elbow and Forearm Trauma Treatment · Bone fractures and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Biomedical Engineering, I-Shou University, Kaohsiung 824, Taiwan
Department of Orthopedics, E-Da Hospital, Kaohsiung 824, Taiwan
School of Medicine, College of Medicine, I-Shou University, Kaohsiung 824, Taiwan
Department of Orthopedics, E-Da Cancer Hospital, Kaohsiung 824, Taiwan
Funding
E-DA Hospital, Taiwan
References (28)
Show source-provided references
1. Acute percutaneous scaphoid fixation10.1302/0301-620X.80B1.0800095 ↗
2. Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures10.2106/00004623-200104000-00001 ↗
3. Scaphoid fractures: What’s hot, what’s not10.2106/JBJS.942ICL ↗
4. Technique for percutaneous fixation of displaced and nondisplaced acute scaphoid fractures and select nonunions10.1016/j.jhsa.2008.04.023 ↗
5. Arthroscopic Reduction and Percutaneous Fixation of Scaphoid Fractures With a Novel Dorsal Technique10.1016/S0030-5898(05)70247-9 ↗
6. Central screw placement in percutaneous screw scaphoid fixation: A cadaveric comparison of proximal and distal techniques10.1016/j.jhsa.2003.09.002 ↗
7. Influence of screw design, sex, and approach in scaphoid fracture fixation10.1007/s11999-011-2218-y ↗
8. Comparison of volar versus dorsal screw fixation for scaphoid waist fractures: A finite element analysis10.1016/j.otsr.2018.07.013 ↗
9. Complications in dorsal percutaneous cannulated screw fixation of nondisplaced scaphoid waist fractures10.1016/j.jhsa.2007.04.003 ↗
10. Comparison of two percutaneous volar approaches for screw fixation of scaphoid waist fractures: Radiographic and biomechanical study of an osteotomy-simulated model10.2106/JBJS.L.01729 ↗
11. Optimization of volar percutaneous screw fixation for scaphoid waist fractures using traction, positioning, imaging, and an angiocatheter guide10.1016/j.jhsa.2011.02.017 ↗
12. Percutaneous transtrapezial fixation of acute scaphoid fractures10.1177/1753193408092785 ↗
13. 3-dimensional analysis of scaphoid fracture angle morphology10.1016/j.jhsa.2014.11.008 ↗
14. Headless compression screw fixation of scaphoid fractures10.1016/j.hcl.2010.04.005 ↗
15. Central placement of the screw in simulated fractures of the scaphoid waist: A biomechanical study10.2106/00004623-200301000-00012 ↗
16. Optimal fixation of oblique scaphoid fractures: A cadaver model10.1016/j.jhsa.2012.04.021 ↗
17. The effects of simulated unstable scaphoid fractures on carpal motion10.1016/0363-5023(89)90022-1 ↗
18. Patterns of healing of scaphoid fractures. The importance of vascularity10.1302/0301-620X.81B1.0810085 ↗
19. Displaced scaphoid waist fractures: The use of a week 4 CT scan to predict the likelihood of union with nonoperative treatment10.1177/1753193411403092 ↗
20. Impact of Screw Length on Proximal Scaphoid Fracture Biomechanics10.1055/s-0039-1685514 ↗
21. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study10.1016/j.injury.2013.04.023 ↗
22. Screw fixation of scaphoid fractures: A biomechanical assessment of screw length and screw augmentation10.1016/j.jhsa.2005.09.014 ↗
23. Displaced scaphoid fractures treated with open reduction and internal fixation with a cannulated screw10.2106/00004623-200005000-00004 ↗
24. Comparison of screw trajectory on stability of oblique scaphoid fractures: A mechanical study10.1016/j.jhsa.2013.12.015 ↗
25. Optimal fixation of acute scaphoid fractures: Finite element analysis10.1016/j.jhsa.2010.05.011 ↗
26. Fracture of the carpal navicular. Diagnosis, non-operative treatment, and operative treatment10.2106/00004623-196042050-00002 ↗
27. Three-dimensional comparison of alternative screw positions versus actual fixation of scaphoid fractures10.1016/j.injury.2017.03.011 ↗
28. Central versus eccentric internal fixation of acute scaphoid fractures10.1016/j.jhsa.2012.09.035 ↗