A traceable calibration procedure for MEMS-based load cells
Source abstract
Abstract
Characterizing the mechanical properties of materials and biological systems at the nanoscale requires accurate measurement of forces on the order of μN and less. Due to the scale of the measurements and size of the instrumentation, calibration of nanoscale devices presents a new challenge in metrology. In order to ensure accuracy of results, traceable calibrations must be performed on nanoscale instrumentation. Our group recently developed a novel MEMS-based high resolution load cell with force resolution on the order of μN. This paper reports on a simple method for traceably calibrating our device using dead weights that could be generalized to other MEMS-based load cells. In this article, fabrication of a MEMS load cell is detailed and we compare our calibrated force–displacement curves to a non-linear theoretical prediction, revealing errors as great as 29%.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced MEMS and NEMS Technologies · Advanced Sensor and Energy Harvesting Materials · Sensor Technology and Measurement Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Bhushan, B., Li, X.: Micromechanical and tribological characterization of doped single-crystal silicon and polysilicon films for microelectromechanical systems devices. J. Mater. Res. 12, 54–63 (1997)10.1557/JMR.1997.0010 ↗
2. Brantley, W.A.: Calculated elastic constants for stress problems associated with semiconductor devices. J. Appl. Phys. 44, 534–535 (1973)10.1063/1.1661935 ↗
3. Frisch-Fay, R.: Flexible bars. Butterworths (1962)
4. Fukuta, Y., Fujita, H., Toshiyoski, H.: Vapor hydrofluoric acid sacrificial release technique for micro electro mechanical systems using labware. Jpn. J. Appl. Phys. 42(6A), 3690–3694 (2003)10.1143/JJAP.42.3690 ↗
5. Lärmer, F., Schilp, A.: Method for anisotropically etching silicon. Patents DE4241045, US 5501893, and EP 625285 (1992)
6. Legtenberg, A.W.G.R., Elwenspoek, M.: Comb-drive actuators for large displacements. J. Micromech. Microeng. 6, 320–329 (1996)10.1088/0960-1317/6/3/004 ↗
7. Legtenberg, R., Tilmans, A.C., Elders, J., Elwenspoek, M.: Stiction of surface microstructures after rinsing and drying: model and investigation of adhesion mechanisms. Sens. Actuators, Phys. A 43, 230–238 (1993)10.1016/0924-4247(93)00654-M ↗
8. Mirfendereski, D., Lin, L., Kiureghian, A.D., Pisano, A.P.: Probabilistic response of micro-fabricated polysilicon beam structures: comparison of analysis and experiments. In: Dynamic Systems and Control Division, vol. 46. ASME (1993)
9. Onoe, Y., Takeo, T.: Probe-type microforce sensor for microactuators. In: Proceedings of SPIE – The International Society for Optical Engineering, vol. 3512, pp. 84–91 (1998)10.1117/12.324088 ↗
10. Pratt, J.R., Newell, D.B., Kramar, J.A., Whitenton, E.: Calibration of piezoresistive cantilever force sensors using the NIST electrostatic force balance. In: Proceedings of IMECE’03, pp. 289–292. ASME, Washington, DC (2003)10.1115/IMECE2003-41164 ↗
11. Saif, M.T.A., MacDonald, N.: Measurement of forces and spring constants of microinstruments. Rev. Sci. Instrum. 69(3), 1410–1422 (1998)10.1063/1.1148809 ↗
12. Samuel, B.A., Desai, A.V., Haque, M.A.: Microscale application of column theory for high resolution force and displacement sensing. Appl. Phys. Lett. 87, 21904–1–3 (2005)10.1063/1.1989440 ↗
13. Sun, Y., Potasek, D.P., Piyabongkarn, D., Rajamani, R., Nelson, B.J.: Actively servoed multi-axis microforce sensors. In: International Conference on Robotics and Automation, pp. 294–299. IEEE, Taipei, Taiwan (2003)
14. Zhang, X.: Silicon microsurgery-force sensor based on optical MEMS encoders. Sensor Rev. 24(1), 37–41 (2004)10.1108/02602280410515806 ↗