journal article·2023-07-21Open access

Enhanced Electrical Injury Using Triangular Interdigitated Electrodes for Catheter-Based Irreversible Electroporation

Dong-Jin Lee, Dae Yu Kim

Applied Sciences· Volume 13· Issue 14

Abstract

Irreversible electroporation (IRE) is a promising nonthermal ablation technique that uses high-voltage electrical pulses to create permanent pores in the cell membrane of target tissue. Recently, endoscopic IRE with catheter-based electrodes has attracted significant attention as a potential alternative tool for gastrointestinal tumors, but it has been challenged owing to the limited electric field distribution in an in-plane electrode configuration, in which rectangular interdigitated electrodes (IDEs) are commonly used. Herein, we report an enhanced electrical injury in tissue using triangular IDEs that cause strong electric fields to be induced at the tip of the electrode fingers. A set of 10 pulses with a duration of 100 μs and a frequency of 1 Hz were delivered to the tissue, and a finite element method was used to calculate the electrical injury in the gastrointestinal model. The probability of cell death by electrical injury at the triangular IDEs increases by approximately 10 times compared to that of conventional rectangular IDEs at the same electrode distance. These results could potentially pave the way toward designing electrodes in catheter-based IRE devices.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microbial Inactivation Methods · Microfluidic and Bio-sensing Technologies · Plasma Applications and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Inha Research Institute for Aerospace Medicine, Inha University, Incheon 22212, Republic of Korea

Center for Sensor Systems, Inha University, Incheon 22212, Republic of Korea

Department of Electrical and Computer Engineering, College of Engineering, Inha University, Incheon 22212, Republic of Korea

Funding

INHA UNIVERSITY Research Grant

References (36)

Show source-provided references
1. Irreversible Electroporation: Background, Theory, and Review of Recent Developments in Clinical Oncology10.1089/bioe.2019.0029 ↗
2. Irreversible electroporation: State of the art10.2147/OTT.S88086 ↗
3. Feasibility of computed tomography-guided irreversible electroporation for porcine kidney ablation10.4103/jcrt.JCRT_594_19 ↗
4. Irreversible electroporation for liver cancer ablation: A meta analysis10.1016/j.ejso.2021.12.015 ↗
5. Irreversible electroporation of the porcine kidney: Temperature development and distribution
6. Saini, A., Breen, I., Alzubaidi, S., Pershad, Y., Sheth, R., Naidu, S., Knuttinen, M.G., Albadawi, H., and Oklu, R. (2019). Irreversible Electroporation in Liver Cancers and Whole Organ Engineering. J. Clin. Med., 8.10.3390/jcm8010022 ↗
7. Ong, S., Leonardo, M., Chengodu, T., Bagguley, D., and Lawrentschuk, N. (2021). Irreversible Electroporation for Prostate Cancer. Life, 11.10.3390/life11060490 ↗
8. High-frequency irreversible electroporation brain tumor ablation: Exploring the dynamics of cell death and recovery10.1016/j.bioelechem.2021.108001 ↗
9. A systematic review of irreversible electroporation in localised prostate cancer treatment10.1111/and.13789 ↗
10. Analysis on reversible/irreversible electroporation region in lung adenocarcinoma cell model in vitro with electric pulses delivered by needle electrodes10.1088/1361-6560/abc12e ↗
11. Safety of Irreversible Electroporation Ablation of the Pancreas10.1097/MPA.0000000000001916 ↗
12. Electroporation-Based Therapy for Brain Tumors: A Review10.1115/1.4051184 ↗
13. Low-Voltage Irreversible Electroporation Using a Comb-Shaped Contact Electrode10.1109/TBME.2019.2914689 ↗
14. Electrical and thermal analyses of catheter-based irreversible electroporation of digestive tract10.1080/02656736.2019.1646928 ↗
15. EUS-guided irreversible electroporation using endoscopic needle-electrode in porcine pancreas10.1007/s00464-018-6425-4 ↗
16. Feasibility and effectiveness of endoscopic irreversible electroporation for the upper gastrointestinal tract: An experimental animal study10.1038/s41598-021-94583-w ↗
17. Experimental model of occluded biliary metal stent recanalization using irreversible electroporation via a tubular catheter10.1080/02656736.2021.1875061 ↗
18. Kim, J., Wi, S.M., Ahn, J.G., Son, S., Lim, H., Park, Y., Eun, H.J., Park, J.B., Lim, H., and Pak, S. (2023). Engineering Geometric Electrodes for Electric Field-Enhanced High-Performance Flexible In-Plane Micro-Supercapacitors. Energy Environ. Mater., e12581.10.1002/eem2.12581 ↗
19. Recent Advances in Microscale Electroporation10.1021/acs.chemrev.1c00677 ↗
20. Kosri, E., Ibrahim, F., Thiha, A., and Madou, M. (2022). Micro and Nano Interdigitated Electrode Array (IDEA)-Based MEMS/NEMS as Electrochemical Transducers: A Review. Nanomaterials, 12.10.3390/nano12234171 ↗
21. Interdigitated ring electrodes: Theory and experiment10.1016/j.jelechem.2013.10.009 ↗
22. Multifunctional Microelectrode for Low-Voltage Pulsed Field Ablation in Atrial Fibrillation10.1109/LED.2022.3208927 ↗
23. Development of contact irreversible electroporation using a comb-shaped miniature electrode10.1299/jtst.2017jtst0023 ↗
24. Analysis of Planar Circular Interdigitated Electrodes for Electroporation10.1080/02564602.2014.1000982 ↗
25. Gastric Wall Thickness and the Choice of Linear Staples in Laparoscopic Sleeve Gastrectomy: Challenging Conventional Concepts10.1007/s11695-016-2516-2 ↗
26. The Role of Conventional Ultrasonography in the Evaluation of Antrum Wall Thickness in Obese Patients10.1007/s11695-016-2221-1 ↗
27. Human tissue thickness measurements from excised sleeve gastrectomy specimens10.1007/s00464-013-3264-1 ↗
28. Parametric study of irreversible electroporation with different needle electrodes: Electrical and thermal analysis10.3109/02656736.2014.937775 ↗
29. Duck, F.A. (1990). Physical Properties of Tissues, Academic Press.10.1016/B978-0-12-222800-1.50006-1 ↗
30. Development of a Multi-Pulse Conductivity Model for Liver Tissue Treated With Pulsed Electric Fields10.3389/fbioe.2020.00396 ↗
31. Electrical Characterization of Human Biological Tissue for Irreversible Electroporation Treatments
32. Tissue heterogeneity in structure and conductivity contribute to cell survival during irreversible electroporation ablation by “electric field sinks’”10.1038/srep08485 ↗
33. Garcia, P.A., Davalos, R.V., and Miklavcic, D. (2014). A Numerical Investigation of the Electric and Thermal Cell Kill Distributions in Electroporation-Based Therapies in Tissue. PLoS ONE, 9.10.1371/journal.pone.0103083 ↗
34. Optimization of Electrode Configuration and Pulse Strength in Irreversible Electroporation for Large Ablation Volumes Without Thermal Damage
35. Quantitative study of electroporation-mediated molecular uptake and cell viability10.1016/S0006-3495(01)76055-9 ↗
36. Pulse Parameters and Thresholds for (ir)Reversible Electroporation on Hepatocellular Carcinoma Cells in Vitro10.1177/15330338221136694 ↗