journal article·2023-05-04Open access

The Effect of Device-Controlled Breathing on the Pulse Arrival Time and the Heart Rate Asymmetry Parameters in Healthy Volunteers

Bella Eszter Ajtay, Szabolcs Béres, László Hejjel

Applied Sciences· Volume 13· Issue 9

Abstract

Background: The development of wearables has facilitated the monitoring of biomedical parameters in everyday life. One of the most common sensors of these gadgets is the photoplethysmograph (PPG); hence, the proper processing and interpretation of the PPG signal are essential. Besides pulse rate detection, these devices—together with an ECG—compute the pulse arrival time (PAT), from which the actual beat-to-beat blood pressure can be estimated. The heart rate shows asymmetrical accelerations and decelerations, quantified by the parameters of heart rate asymmetry (HRA). In the present study, we investigated the influences of different breathing-patterns on the PATs and HRA parameters. Methods: The authors evaluated 5 min simultaneous respiratory-, ECG- and PPG-signal recordings of 35 healthy, young volunteers specifically expressing the following breathing patterns: metronome-controlled inspiration, and both inspiration and expiration controlled at 1:1 and 1:2 ratios, respectively. The records were analyzed by HRVScan_Merge v3.2 software. The PAT values were calculated at eight different reference points. The HRA parameters and the PAT values at different breathing patterns were compared using the Friedman test and post hoc Wilcoxon paired-sample test. Results: Porta- and Guzik-indices significantly increased at 1:1 breathing compared to 1:2 and single-paced breathing. PATs increased significantly in dual-paced series compared to single-paced series at each reference point. Conclusion: Based on our results, the increased PATs at dual-paced versus single-paced breathing may indicate the involvement of cognitive functions. The symmetrical respiration ratio increases the heart rate symmetry; however, this effect is not detectable in the periphery through the PATs.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Heart Rate Variability and Autonomic Control · ECG Monitoring and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Heart Institute, Medical School, University of Pécs, Ifjúság Str. 13, H-7624 Pécs, Hungary

Zsigmondy Vilmos SPA Hospital, Zsigmondy Prom. 1, H-7815 Harkány, Hungary

Funding

University of Pécs, Medical School, Hungary

References (46)

Show source-provided references
1. A Survey of Wearable Devices and Challenges10.1109/COMST.2017.2731979 ↗
2. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/R01 ↗
3. Kyriacou, P.A., and Allen, J. (2021). Photoplethysmography: Technology, Signal Analysis and Applications, Academic Press.
4. Noncontact monitoring breathing pattern, exhalation flow rate and pulse transit time10.1109/TBME.2014.2327024 ↗
5. The oscillating pulse arrival time as a physiological explanation regarding the difference between ECG- and Photoplethysmogram-derived heart rate variability parameters10.1016/j.bspc.2022.104033 ↗
6. Accuracy of Consumer Wearable Heart Rate Measurement during an Ecologically Valid 24-Hour Period: Intraindividual Validation Study10.2196/10828 ↗
7. The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteers10.1016/j.bspc.2021.102589 ↗
8. On the Minimal Adequate Sampling Frequency of the Photoplethysmogram for Pulse Rate Monitoring and Heart Rate Variability Analysis in Mobile and Wearable Technology10.2478/msr-2019-0030 ↗
9. Effects of using different algorithms and fiducial points for the detection of interbeat intervals, and different sampling rates on the assessment of pulse rate variability from photoplethysmography10.1016/j.cmpb.2022.106724 ↗
10. Mejia-Mejia, E., May, J.M., and Kyriacou, P.A. (2021, January 1–5). Effect of Filtering of Photoplethysmography Signals in Pulse Rate Variability Analysis. Proceedings of the 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Jalisco, Mexico.10.1109/EMBC46164.2021.9629521 ↗
11. Extraction of respiratory signals from the electrocardiogram and photoplethysmogram: Technical and physiological determinants10.1088/1361-6579/aa670e ↗
12. Heart rate variability analysis10.1556/APhysiol.88.2001.3-4.4 ↗
13. Asymmetric properties of long-term and total heart rate variability10.1007/s11517-011-0834-z ↗
14. Effects of emotions on heart rate asymmetry10.1111/psyp.13318 ↗
15. Heart rate asymmetry follows the inspiration/expiration ratio in healthy volunteers10.1088/0967-3334/33/10/1717 ↗
16. Defining asymmetry in heart rate variability signals using a Poincaré plot10.1088/0967-3334/30/11/007 ↗
17. Temporal asymmetries of short-term heart period variability are linked to autonomic regulation10.1152/ajpregu.00129.2008 ↗
18. How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram10.1016/j.ijcard.2012.03.119 ↗
19. Pulse rate variability: A new biomarker, not a surrogate for heart rate variability10.1186/s40101-020-00233-x ↗
20. Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera
21. Relationship between Heart Rate Variability and Pulse Rate Variability Measures in Patients after Coronary Artery Bypass Graft Surgery10.3389/fcvm.2021.749297 ↗
22. A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability
23. Signal-to-noise ratio is more important than sampling rate in beat-to-beat interval estimation from optical sensors10.1016/j.bspc.2022.103538 ↗
24. Effects of noise and filtering strategies on the extraction of pulse rate variability from photoplethysmograms10.1016/j.bspc.2022.104291 ↗
25. Optimal fiducial points for pulse rate variability analysis from forehead and finger photoplethysmographic signals10.1088/1361-6579/ab009b ↗
26. Pulse arrival time as a surrogate of blood pressure10.1038/s41598-021-01358-4 ↗
27. Cuffless Blood Pressure Estimation during Moderate- and Heavy-Intensity Exercise Using Wearable ECG and PPG10.1109/JBHI.2022.3207947 ↗
28. A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study10.1111/psyp.14173 ↗
29. Louka, K., Cox, J., Tan, I., Avolio, A.P., O’Rourke, M.F., and Butlin, M. (2021, January 26). An investigation of the individualized, two-point calibration method for cuffless blood pressure estimation using pulse arrival time: An historical perspective using the Casio BP-100 digital watch. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, Jalisco, Mexico.10.1109/EMBC46164.2021.9630063 ↗
30. Non-invasive quantification of the effect of device-guided slow breathing with direct feedback to the patient to reduce blood pressure10.1088/1361-6579/abb320 ↗
31. Effects of slow and regular breathing exercise on cardiopulmonary coupling and blood pressure10.1007/s11517-016-1517-6 ↗
32. Cellular phone irradiation of the head affects heart rate variability depending on inspiration/expiration ratio10.21873/invivo.11357 ↗
33. Breathing pattern and lung volumes during exercise10.1111/j.1748-1716.1984.tb07381.x ↗
34. Chen, Y., Li, D., Li, Y., Ma, X., and Wei, J. (2016). Lecture Notes of the Institute for Computer Sciences, Social-Informatics and Telecommunications Engineering, LNICST, Springer International Publishing.
35. Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database10.1109/TBME.1986.325695 ↗
36. Holoborodko, P. (2021, December 12). Smooth Noise-Robust Differentiators. Available online: http://www.holoborodko.com/pavel/numerical-methods/numerical-derivative/smooth-low-noise-differentiators/.
37. Bonferroni and Šidák corrections for multiple comparisons
38. Heart rate asymmetry by Poincaré plots of RR intervals10.1515/BMT.2006.054 ↗
39. Heart Rate Asymmetry Analysis during Head-Up Tilt Test in Healthy Men
40. The physiological effects of slow breathing in the healthy human10.1183/20734735.009817 ↗
41. Cox, J., Avolio, A.P., Louka, K., Shirbani, F., Tan, I., and Butlin, M. (2021, January 1–5). Blood pressure-independent neurogenic effect on conductance and resistance vessels: A consideration for cuffless blood pressure measurement?. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, Virtual, Jalisco, Mexico.10.1109/EMBC46164.2021.9629936 ↗
42. Clinical utility of paced breathing as a concentration meditation practice10.1016/j.ctim.2012.07.008 ↗
43. The P300 Wave of the Human Event-Related Potential10.1097/00004691-199210000-00002 ↗
44. Simple and choice reaction times are prolonged following extracorporeal circulation: A potential method for the assessment of acute neurocognitive deficit
45. Skin sympathetic nerve activity and event-related potentials during auditory oddball paradigms10.1016/0165-1838(96)00043-4 ↗
46. Brain and autonomic association accompanying stochastic decision-making10.1016/j.neuroimage.2009.07.060 ↗