journal article·2023-04-26Open access

HCI-Based Wireless System for Measuring the Concentration of Mining Machinery and Equipment Operators

Jerzy Jagoda, Mariusz Woszczyński, Bartosz Polnik, Przemysław Falkowski-Gilski

Applied Sciences· Volume 13· Issue 9

Abstract

Maintaining stable and reliable working conditions is a matter of vital importance for various companies, especially those involving heavy machinery. Due to human exhaustion, as well as unpredicted hazards and dangerous situations, the personnel has to take actions and wisely plan each move. This paper presents a human–computer interaction (HCI)-based system that uses a concentration level measurement function to increase the safety of machine and equipment operators. The system has been developed in response to the results of user experience (UX) analyses of the state of occupational safety, which indicate that the most common cause of accidents is the so-called insufficient concentration while performing work. The paper presents the reasons for addressing this issue and a description of the proposed electroencephalography (EEG)-based solution in the form of a concentration measurement system concept. We discuss in-field measurements of such a prototype solution, together with an analysis of obtained results. The method of implementing a wireless communication interface is also provided, along with a visualization application.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Quality and Safety in Healthcare · Human-Automation Interaction and Safety · Healthcare Technology and Patient Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

KOMAG Institute of Mining Technology, Pszczynska St. 37, 44-101 Gliwice, Poland

Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology, Narutowicza St. 11/12, 80-233 Gdansk, Poland

Funding

Gdansk University of Technology

References (34)

Show source-provided references
1. Real-time EEG-based emotion monitoring using stable features10.1007/s00371-015-1183-y ↗
2. (2023, March 08). Polish Higher Mining Office, Available online: www.wug.gov.pl/download/6178.pdf.
3. Preliminary identification and evaluation of parameters affecting the performance of the operator-machine earthmoving system
4. Safety situation in the workplace as function of a machine operator’s level of training
5. Using mindwave to biomeasurment attention factor in research field related with passenger vehicle simulator
6. System pomiaru koncentracji operatora maszyn i urządzeń górniczych
7. Wedde, F. (2005, January 25–29). BeeAdHoc: An energy efficient routing algorithm for mobile ad hoc networks inspired by bee beahavior. Proceedings of the Genetic and Evolutionary Computation Conference, Washington, DC, USA.10.1145/1068009.1068034 ↗
8. Mechatronic systems in mining roadheaders—Examples of solutions
9. Intelligent self-powered sensors in the state-of-the-art control systems of mining machines
10. System sterowania ścianowym przenośnikiem zgrzebłowym
11. Systemy monitoringu, diagnostyki i sterowania maszyn górniczych
12. Hou, X., Liu, Y., Sourina, O., Tan, Y.R.E., Wang, L., and Mueller-Wittig, W. (2015, January 9–12). EEG based stress monitoring. Proceedings of the 2015 IEEE International Conference on Systems, Man, and Cybernetics, Hong Kong, China.10.1109/SMC.2015.540 ↗
13. Monitoring working memory load during computer-based tasks with EEG pattern recognition methods10.1518/001872098779480578 ↗
14. Estimating alertness from the EEG power spectrum10.1109/10.553713 ↗
15. Monitoring task loading with multivariate EEG measures during complex forms of human-computer interaction10.1518/001872001775898287 ↗
16. Response error correction-a demonstration of improved human-machine performance using real-time EEG monitoring10.1109/TNSRE.2003.814446 ↗
17. Control of a simple electrical device by means of an EEG signal
18. (2023, March 08). NeuroSky. Available online: https://neurosky.com/biosensors/eeg-sensor/biosensors/.
19. EEG signal acquisition using Neurosky Mindwave Mobile for control processes implemented from the android system level
20. New chronic EEG electrode for critical/intensive care unit monitoring10.1097/01.WNP.0000152659.30753.47 ↗
21. International Electrotechnical Commission (2008). IEC 61000-4-2 Recommendation, International Electrotechnical Commission. Electromagnetic Compatibility (EMC)—Part 4-2: Testing and Measurement Techniques—Electrostatic Discharge Immunity Test.
22. Rana, K.D., and Vaina, L.M. (2014). Functional roles of 10 Hz alpha-band power modulating engagement and disengagement of cortical networks in a complex visual motion task. PLoS ONE, 9.10.1371/journal.pone.0107715 ↗
23. Identifying periods of drowsy driving using EEG
24. The EEG based driver safety system10.7763/IJET.2012.V4.378 ↗
25. Dispersed, self-organizing sensory networks supporting the technological processes
26. Jagoda, J., and Stankiewicz, K. (2019, January 25–28). Intelligent routing algorithms in the complex sensors network for control energy storage. Proceedings of the 20th International Conference on Advanced Batteries, Accumulators and Fuel Cells, Brno, Czech Republic.
27. A method for the self-organization of a sensor network in belt conveyor exploitation
28. Protokoły trasowania w sieciach ad hoc
29. Di Caro, G., Ducatelle, F., and Gamberdella, L.M. (2005, January 8–10). Swarm intelligence for routing in mobile ad hoc networks. Proceedings of the 2015 IEEE Swarm Intelligence Symposium, Pasadena, CA, USA.
30. Direct electrical stimulation of the human brain has inverse effects on the theta and gamma neural activities10.1109/TBME.2021.3082320 ↗
31. Independent dynamics of low, intermediate, and high frequency spectral intracranial EEG activities during human memory formation10.1016/j.neuroimage.2021.118637 ↗
32. Intracranial electrophysiological recordings from the human brain during memory tasks with pupillometry10.1038/s41597-021-01099-z ↗
33. Occupational health and safety management in hard coal mines in the aspect of dust hazard
34. Mechatronic systems developed at the KOMAG