Influence of the Number of Microthreads on Marginal Bone Loss: A Five-Year Retrospective Clinical Study in Humans
Source abstract
Abstract
The purpose of the present study was to evaluate the clinical and radiographic outcomes of the number of microthreads on marginal bone over 5 years. Thirty-two implants were placed in 32 patients with partially edentulous maxillae or mandibles. Two implants with the same characteristics were placed: the first one had a 1 mm crest module and 3 microthreads (Q); and the second one had a 3 mm crest module and nine microthreads (S). The prosthesis was inserted 3 months after implant placement. Clinical and radiographic examinations were performed at the one-week, one-month, and three-month follow-up visits and then every six months until a five-year follow-up period was completed. After 5 years of follow-up, five patients withdrew from the study. Complete data were available for 27 implants, with a 100% implant survival rate. No cases of peri-implantitis were diagnosed. The average bone loss was 0.65 mm (C.I. 0.21–1.09) for Q implants and 0.86 mm (C.I. 0.39–1.33) for S implants, with no statistically significant difference. The bone level does not vary between implants with three and nine microthreads or with a 1 mm and 3 mm crest module. No differences in clinical parameters were found.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Periodontal Regeneration and Treatments · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Periodontology, Medicine and Dentistry Faculty, Murcia University, 30008 Murcia, Spain
References (53)
Show source-provided references
1. Biological aspects of implant dentistry: Osseointegration10.1111/j.1600-0757.1994.tb00006.x ↗
2. Criteria for success of osseointegrated endosseous implants10.1016/0022-3913(89)90081-4 ↗
3. Clinical and Radiologic Outcomes after Submerged and Transmucosal Implant Placement with Two-Piece Implants in the Anterior Maxilla and Mandible: 3-Year Results of a Randomized Controlled Clinical Trial10.1111/cid.12107 ↗
4. The Causes of Early Implant Bone Loss: Myth or Science?10.1902/jop.2002.73.3.322 ↗
5. A review article on factors affecting bone loss in dental implants10.1016/j.matpr.2020.07.428 ↗
6. Clinical and Radiological Outcomes of Two Implants with Different Prosthetic Interfaces and Neck Configurations: Randomized, Controlled, Split-Mouth Clinical Trial10.1111/j.1708-8208.2012.00465.x ↗
7. Titanium dental implants with different collar design and surface modifications: A systematic review on survival rates and marginal bone levels10.1111/clr.13389 ↗
8. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
9. The influence of thread geometry on implant osseointegration under immediate loading: A literature review10.4047/jap.2014.6.6.547 ↗
10. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
11. Current trends in dental implants10.5125/jkaoms.2014.40.2.50 ↗
12. Does Implant Staging Choice Affect Crestal Bone Loss?10.1016/j.joms.2011.09.006 ↗
13. Three-Dimensional Finite Element Analysis of the Effect of Endosteal Implants with Different Macro Designs on Stress Distribution in Different Bone Qualities10.11607/jomi.7058 ↗
14. Implant materials, designs, and surface topographies: Their effect on osseointegration. A literature review
15. High surface energy enhances cell response to titanium substrate microstructure10.1002/jbm.a.30320 ↗
16. Platform switch versus platform match in the posterior mandible–1-year results of a multicentre randomized clinical trial10.1111/jcpe.12244 ↗
17. Connective tissue attachment to laser-microgrooved abutments: A human histologic case report
18. Influence of the Size of the Microgap on Crestal Bone Levels in Non-Submerged Dental Implants: A Radiographic Study in the Canine Mandible10.1902/jop.2002.73.10.1111 ↗
19. Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non-Submerged and Submerged Implants in the Canine Mandible10.1902/jop.2000.71.9.1412 ↗
20. Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible10.1902/jop.1997.68.11.1117 ↗
21. Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non-Submerged Implants in the Canine Mandible10.1902/jop.2001.72.10.1372 ↗
22. Finite element analysis of crestal bone loss around porous-coated dental implants10.1002/jab.770060408 ↗
23. Comparative Analysis of Peri-Implant Marginal Bone Loss Based on Microthread Location: A 1-Year Prospective Study After Loading10.1902/jop.2009.090330 ↗
24. Long-term evaluation of Astra Tech and Brånemark implants in patients treated with full-arch bridges. Results after 12-15 years10.1111/j.1600-0501.2012.02524.x ↗
25. Effect of surface topography of screw-shaped titanium implants in humans on clinical and radiographic parameters: A 12-year prospective study10.1111/j.1600-0501.2009.01768.x ↗
26. Rueden, C.T., Schindelin, J., Hiner, M.C., Dezonia, B.E., Walter, A.E., Arena, E.T., and Eliceiri, K.W. (2017). ImageJ2: ImageJ for the next generation of scientific image data. BMC Bioinform., 18.10.1186/s12859-017-1934-z ↗
27. General Assembly of the World Medical Association (2014). World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects. J. Am. Coll. Dent., 81, 14–18.10.1515/jwiet-2014-0117 ↗
28. Research on implants and osseointegration10.1111/prd.12254 ↗
29. Innovations in Dental Implant Design for Current Therapy10.1016/j.coms.2011.02.001 ↗
30. An effect of micro-threaded design of implant neck on stress distribution to improve the survival rate of dental implants10.1063/5.0057930 ↗
31. Crestal bone changes at nonsubmerged implants (Camlog) with different machined collar lengths: A histomorphometric pilot study in dogs
32. Marginal tissue response to different implant neck design10.4047/jkap.2008.46.6.602 ↗
33. Impact of machined versus structured implant shoulder designs on crestal bone level changes: A randomized, controlled, multicenter study10.1186/s40729-022-00432-4 ↗
34. The biomechanics of force distribution in implant-supported prostheses
35. Influence of implant neck and abutment characteristics on peri-implant tissue health and stability. Oral reconstruction foundation consensus report10.1111/clr.13439 ↗
36. The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis10.1016/j.jds.2019.12.003 ↗
37. Radiographic evaluation of marginal bone level around implants with different neck designs after 1 year
38. The implant neck: Smooth or provided with retention elements. A biomechanical approach10.1034/j.1600-0501.1999.100506.x ↗
39. A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysis10.1034/j.1600-0501.2003.140306.x ↗
40. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures10.3109/00016357.2011.572287 ↗
41. A rough surface implant neck with microthreads reduces the amount of marginal bone loss: A prospective clinical study10.1111/j.1600-0501.2009.01730.x ↗
42. Radiographic evaluation of marginal bone levels adjacent to parallel-screw cylinder machined-neck implants and rough-surfaced microthreaded implants using digitized panoramic radiographs10.1111/j.1600-0501.2008.01684.x ↗
43. Influence of implant neck design on crestal bone loss: A comparative study10.4103/njs.NJS_28_19 ↗
44. Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis10.1155/2016/4987526 ↗
45. Tissue Characteristics at Microthreaded Implants: An Experimental Study in Dogs10.1111/j.1708-8208.2006.00016.x ↗
46. The effect of microthread design on magnitude and distribution of stresses in bone: A three-dimensional finite element analysis10.4103/1735-3327.240475 ↗
47. Effect of implant macrogeometry on peri-implant healing outcomes: A randomized clinical trial10.1007/s00784-018-2463-5 ↗
48. Effect of microthread on the maintenance of marginal bone level: A 3-year prospective study10.1111/j.1600-0501.2007.01302.x ↗
49. Aslroosta, H., Akbari, S., Naddafpour, N., Adnaninia, S.T., Khorsand, A., and Esfahani, N.N. (2021). Effect of microthread design on the preservation of marginal bone around immediately placed implants: A 5-years prospective cohort study. BMC Oral Health, 21.10.1186/s12903-021-01881-w ↗
50. Radiographic and clinical outcomes of rooted, platform-switched, microthreaded implants with a sandblasted, large-grid, and acid-etched surface: A 5-year prospective study10.1111/cid.12543 ↗
51. Socket healing with and without immediate implant placement10.1111/prd.12252 ↗
52. One-stage versus two-stage technique using two splinted extra-short implants: A multicentric split-mouth study with a one-year follow-up10.1111/cid.13113 ↗
53. Stacchi, C., Lamazza, L., Rapani, A., Troiano, G., Messina, M., Antonelli, A., Giudice, A., and Lombardi, T. (Clin. Implant. Dent. Relat. Res., 2023). Marginal bone changes around platform-switched conical connection implants placed 1 or 2 mm subcrestally: A multicenter crossover randomized controlled trial, Clin. Implant. Dent. Relat. Res., Epub ahead of print.10.1111/cid.13186 ↗