Test of Broken Suspender Specimen and Equivalent Static Calculation Method for Half-Through and Through Concrete-Filled Steel Tubular Arch Bridges

Kangming Chen, Jianping Luo, Qingxiong Wu, Huanwei Wang

Applied Sciences· Volume 12· Issue 22

Abstract

In response to the frequent collapse of main girders caused by the breakage of suspenders on half-through and through arch bridges, a test specimen has been designed and fabricated with a through concrete-filled steel tube (CFST) arch bridge as the engineering background. A new electromagnetic disconnect trigger is employed to realize the rapid suspender breakage in the test specimen. Dynamic response tests of the residual structure of the arch bridge after suspender failures employing the test specimen have been carried out. A finite element model accounting for the suspender breakage dynamic process has been constructed by implementing ANSYS/LS-DYNA, and the results of the test and finite element analysis are compared. In order to simplify the dynamic response calculation process of the residual structure after hanger failures, the dynamic coefficient is introduced, and an equivalent static calculation method (ESCM) considering the dynamic effect of the suspender fracture is presented. Eleven kinds of CFST standard arch bridges with different spans are constructed, the static and dynamic effects of the standard arch bridge with various dynamic coefficients are compared, and then their corresponding dynamic coefficients for various suspender fractures are determined. The obtained results reveal that the proposed electromagnetic suspender breakage trigger can realize the hanger fracturing within 0.1 s, which accurately simulates the fracture process of an actual bridge suspender, and the influence on the value of the dynamic coefficient can be ignored when the duration for suspender fracture is less than or equal to 0.15 s. The influence of suspender fracture on the displacement and stress of the longitudinal beam is more notable than those of the arch rib. In particular, the long suspender breakage has the highest influence on the displacement and stress of the longitudinal beam and arch rib. The fracture of the second short suspender has a remarkable impact on the suspender force of the adjacent hanger. When the ESCM is utilized to assess the mechanical behavior of the half-through and through CFST arch bridge, the dynamic coefficients of the longitudinal beam (suspender) were evaluated to be, conservatively, 1.8 (1.8) and 1.8 (1.7), respectively.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Concrete Corrosion and Durability · Structural Response to Dynamic Loads · Geotechnical Engineering and Underground Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Civil Engineering, Fuzhou University, Fuzhou 350108, China

Funding

National Natural Science Foundation of China · National Key Research and Development Program of China

References (23)

Show source-provided references
1. Effect of tensile overloads on fatigue crack growth of high strength steel wires10.1016/j.matdes.2013.05.063 ↗
2. Mechanical behavior of damaged strand suspender with asymmetric broken wires in arch bridges
3. Robustness design of concrete-filled steel tube arch bridges
4. Huang, F.H. (2021). Vulnerability Analysis of Through Concrete-Filled Steel Tube Arch Bridge, Hefei University of Technology.
5. Technical condition evaluation of half-through and through arch bridges considering robustness
6. (2013). Technical Code for Concrete-Filled Steel Tube Arch Bridges (Standard No. GB 50923-2013).
7. Avoiding Disproportionate Collapse of Major Bridges10.2749/101686609788957838 ↗
8. Zoli, T.P., and Steinhouse, J. (2010). Some Considerations in the Design of Long Span Bridges against Progressive Collapse, HNTB Corp.
9. Design of long span bridges for cable loss
10. Research on robustness performance of shallow type arch bridge based on suspender damage
11. Improved hanger design for robustness of through-arch bridges
12. Response of under-deck cable-stayed bridges to the accidental breakage of stay cables10.1016/j.engstruct.2009.02.027 ↗
13. Research on structural robustness for single cable loss in combination
14. Research on Force Performance of Cable Breaking on Cable-stayed Bridges Applied Mechanics and Materials10.4028/www.scientific.net/AMM.644-650.5061 ↗
15. Dynamic analysis for cable loss of a rigid-frame tied through concrete-filled steel tubular arch bridge
16. Dynamic Response and Robustness Evaluation of Cable-Supported Arch Bridges Subjected to Cable Breaking10.1155/2021/6689630 ↗
17. Yu, Y.G. (2015). Study on Robustness of Suspended Floor System in Half-Through and Through Arch Bridges, Fuzhou University.
18. Experimental and numerical study on cable breakage equivalent force in cable-stayed structures consisting of low-relaxation seven-wire steel strands10.1016/j.istruc.2020.05.028 ↗
19. Responses of self-anchored suspension bridge to sudden breakage of hangers10.12989/sem.2014.50.2.241 ↗
20. Stress corrosion cracking: Characteristics, mechanisms and experimental study10.1007/s00170-017-0709-z ↗
21. Assessment of the potentials of implicit integration method in discrete element modelling of granular matter10.1016/j.compchemeng.2012.10.009 ↗
22. Clough, R.W., and Penzien, J. (2003). Dynamics of Structures. Computers and Structures, McGraw-Hill College.
23. (2015). Specifications for Design of Highway Concrete-Filled Steel Tubular Arch Bridge (Standard No. JTG/T D65-06-2015).